Literature DB >> 21938663

Assessment technique for computer-aided manufactured sockets.

Joan E Sanders1, Michael R Severance.   

Abstract

This article presents an assessment technique for testing the quality of prosthetic socket fabrication processes at computer-aided manufacturing facilities. The assessment technique is potentially useful to both facilities making sockets and companies marketing manufacturing equipment seeking to assess and improve product quality. To execute the assessment technique, an evaluator fabricates a collection of test models and sockets using the manufacturing suite under evaluation, then measures their shapes using scanning equipment. Overall socket quality is assessed by comparing socket shapes with electronic file (e-file) shapes. To characterize carving performance, model shapes are compared with e-file shapes. To characterize forming performance, socket shapes are compared with model shapes. The mean radial error (MRE), which is the average difference in radii between the two compared shapes, provides insight into sizing quality. Interquartile range (IQR), the range of radial error for the best-matched half of the points on the compared socket surfaces, provides insight into regional shape quality. The source(s) of socket shape error may be pinpointed by separately determining MRE and IQR for carving and forming. The developed assessment technique may provide a useful tool to the prosthetics community and industry to help identify problems and limitations in computer-aided manufacturing and give insight into appropriate modifications to overcome them.

Entities:  

Mesh:

Year:  2011        PMID: 21938663      PMCID: PMC4440793          DOI: 10.1682/jrrd.2010.11.0213

Source DB:  PubMed          Journal:  J Rehabil Res Dev        ISSN: 0748-7711


  13 in total

1.  Central fabrication: carved positive assessment.

Authors:  Joan E Sanders; Michael R Severance; Timothy R Myers; Marcia A Ciol
Journal:  Prosthet Orthot Int       Date:  2011-03       Impact factor: 1.895

2.  An evaluation of computer aided design of below-knee prosthetic sockets.

Authors:  A K Topper; G R Fernie
Journal:  Prosthet Orthot Int       Date:  1990-12       Impact factor: 1.895

3.  CAD/CAM transtibial prosthetic sockets from central fabrication facilities: how accurate are they?

Authors:  Joan E Sanders; Ellen L Rogers; Elizabeth A Sorenson; Gregory S Lee; Daniel C Abrahamson
Journal:  J Rehabil Res Dev       Date:  2007

4.  Evaluation of the effect of shape on a contemporary CAD system.

Authors:  T McGarry; B McHugh; A Buis; G McKay
Journal:  Prosthet Orthot Int       Date:  2008-06       Impact factor: 1.895

5.  A quantitative method for comparing and evaluating manual prosthetic socket modifications.

Authors:  E D Lemaire; F Johnson
Journal:  IEEE Trans Rehabil Eng       Date:  1996-12

6.  Volume fluctuations in the residual limbs of lower limb amputees.

Authors:  G R Fernie; P J Holliday
Journal:  Arch Phys Med Rehabil       Date:  1982-04       Impact factor: 3.966

7.  A preliminary investigation into the development of 3-D printing of prosthetic sockets.

Authors:  Nicholas Herbert; David Simpson; William D Spence; William Ion
Journal:  J Rehabil Res Dev       Date:  2005 Mar-Apr

8.  The VA-Cyberware lower limb prosthetics-orthotics optical laser digitizer.

Authors:  V L Houston; C P Mason; A C Beattie; K P LaBlanc; M Garbarini; E J Lorenze; C M Thongpop
Journal:  J Rehabil Res Dev       Date:  1995-02

9.  CAD CAM trans-tibial temporary prosthesis: analysis and comparison with an established technique.

Authors:  G K Ruder
Journal:  Prosthet Orthot Int       Date:  1992-12       Impact factor: 1.895

10.  Consistency, precision, and accuracy of optical and electromagnetic shape-capturing systems for digital measurement of residual-limb anthropometrics of persons with transtibial amputation.

Authors:  Mark D Geil
Journal:  J Rehabil Res Dev       Date:  2007
View more
  2 in total

1.  COMPARATIVE EFFECTIVENESS OF AN ADJUSTABLE TRANSFEMORAL PROSTHETIC INTERFACE ACCOMMODATING VOLUME FLUCTUATION: CASE STUDY.

Authors:  Jason T Kahle; Tyler D Klenow; M Jason Highsmith
Journal:  Technol Innov       Date:  2016-09

2.  Northwestern University Flexible Subischial Vacuum Socket for persons with transfemoral amputation-Part 1: Description of technique.

Authors:  Stefania Fatone; Ryan Caldwell
Journal:  Prosthet Orthot Int       Date:  2017-01-17       Impact factor: 1.895

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.