Literature DB >> 18569882

Evaluation of the effect of shape on a contemporary CAD system.

T McGarry1, B McHugh, A Buis, G McKay.   

Abstract

The TracerCAD system is one of the leading prosthetic CAD systems in the world and is increasingly used in clinics to replace traditional methods of residual limb shape capture. Accurate dimensional capture of the residuum is arguably the most important process in the production of a prosthetic socket. TracerCAD system accuracy has previously been tested on a cylindrical model but not a trans-tibial shape. Residual limbs are irregular in shape therefore it is important to assess if shape has an effect on the accuracy of data collected when using TracerCAD. The objective of this study is to investigate the accuracy of the TracerCAD system in measuring a model of a trans-tibial stump of known dimensions and volume. A model of a trans-tibial stump was produced and filled with plaster and measured using a data acquisition system with an accuracy of five micron (0.005 mm). The model was repeatedly traced using the TracerCAD system by an individual user. The mean value of measures taken by the dynamic indicator was calculated and compared to individual and mean values of TracerCAD measurement. Results showed that the TracerCAD measurement was not as consistent on the more complex trans-tibial model as for the cylindrical model.

Mesh:

Year:  2008        PMID: 18569882     DOI: 10.1080/03093640802015920

Source DB:  PubMed          Journal:  Prosthet Orthot Int        ISSN: 0309-3646            Impact factor:   1.895


  5 in total

1.  Assessment technique for computer-aided manufactured sockets.

Authors:  Joan E Sanders; Michael R Severance
Journal:  J Rehabil Res Dev       Date:  2011

Review 2.  Residual limb volume change: systematic review of measurement and management.

Authors:  Joan E Sanders; Stefania Fatone
Journal:  J Rehabil Res Dev       Date:  2011

3.  Reliability and validity of 3D limb scanning for ankle-foot orthosis fitting.

Authors:  Olivia A Powers; Jeff R Palmer; Jason M Wilken
Journal:  Prosthet Orthot Int       Date:  2022-02-01       Impact factor: 1.672

4.  Residual limb volume fluctuations in transfemoral amputees.

Authors:  Linda Paternò; Michele Ibrahimi; Elisa Rosini; Giuseppe Menfi; Vito Monaco; Emanuele Gruppioni; Leonardo Ricotti; Arianna Menciassi
Journal:  Sci Rep       Date:  2021-06-10       Impact factor: 4.379

5.  Validity and reliability of a novel 3D scanner for assessment of the shape and volume of amputees' residual limb models.

Authors:  Elena Seminati; David Canepa Talamas; Matthew Young; Martin Twiste; Vimal Dhokia; James L J Bilzon
Journal:  PLoS One       Date:  2017-09-08       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.