Consistency, precision, and accuracy of optical and electromagnetic shape-capturing systems for digital measurement of residual-limb anthropometrics of persons with transtibial amputation.

Mark D Geil1.   

Abstract

Computer-aided design (CAD) and computer-aided manufacturing systems have been adapted for specific use in prosthetics, providing practitioners with a means to digitally capture the shape of a patient's limb, modify the socket model using software, and automatically manufacture either a positive model to be used in the fabrication of a socket or the socket itself. The digital shape captured is a three-dimensional (3-D) model from which standard anthropometric measures can be easily obtained. This study recorded six common anthropometric dimensions from CAD shape files of three foam positive models of the residual limbs of persons with transtibial amputations. Two systems were used to obtain 3-D models of the residual limb, a noncontact optical system and a contact-based electromagnetic field system, and both experienced practitioners and prosthetics students conducted measurements. Measurements were consistent; the mean range (difference of maximum and minimum) across all measurements was 0.96 cm. Both systems provided similar results, and both groups used the systems consistently. Students were slightly more consistent than practitioners but not to a clinically significant degree. Results also compared favorably with traditional measurement, with differences versus hand measurements about 5 mm. These results suggest the routine use of digital shape capture for collection of patient volume information.

Entities:  

Mesh:

Year:  2007        PMID: 18247248     DOI: 10.1682/jrrd.2006.08.0088

Source DB:  PubMed          Journal:  J Rehabil Res Dev        ISSN: 0748-7711


  5 in total

1.  Assessment technique for computer-aided manufactured sockets.

Authors:  Joan E Sanders; Michael R Severance
Journal:  J Rehabil Res Dev       Date:  2011

Review 2.  Residual limb volume change: systematic review of measurement and management.

Authors:  Joan E Sanders; Stefania Fatone
Journal:  J Rehabil Res Dev       Date:  2011

3.  Standardized Three-Dimensional Lateral Distraction Test: Its Reliability to Assess Medial Canthal Tendon Laxity.

Authors:  Xiaoyi Hou; Alexander C Rokohl; Yongwei Guo; Ludwig M Heindl; Marius M Meinke; Jinhua Liu; Senmao Li; Wanlin Fan; Ming Lin; Renbing Jia
Journal:  Aesthetic Plast Surg       Date:  2021-07-07       Impact factor: 2.708

4.  Volume Fluctuations in Active and Nonactive Transtibial Prosthetics Users.

Authors:  Nur Afiqah Hamzah; Nasrul Anuar Abd Razak; Mohd Sayuti Ab Karim; Siti Zuliana Salleh
Journal:  Biomed Res Int       Date:  2022-09-12       Impact factor: 3.246

5.  Validity and reliability of a novel 3D scanner for assessment of the shape and volume of amputees' residual limb models.

Authors:  Elena Seminati; David Canepa Talamas; Matthew Young; Martin Twiste; Vimal Dhokia; James L J Bilzon
Journal:  PLoS One       Date:  2017-09-08       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.