Literature DB >> 21920858

Reducing patient radiation dose during CT-guided procedures: demonstration in spinal injections for pain.

T M Shepherd1, C P Hess, C T Chin, R Gould, W P Dillon.   

Abstract

BACKGROUND AND
PURPOSE: CT guidance may improve precision for diagnostic and therapeutic spinal injections, but it can increase patient radiation dose. This study examined the impact of reducing tube current on patient radiation exposure and the technical success for these procedures, by using axial acquisitions for short scan lengths and eliminating nonessential imaging.
MATERIALS AND METHODS: Our institutional review board approved retrospective analysis of records from 100 consecutive outpatients undergoing spinal injections for pain before and after the CT protocol modification to reduce radiation dose. Data collected included patient age and sex, response to injection, number of sites and spinal levels treated, injection type, performing physician, CT acquisition method, number of imaging series, tube current, scan length, and DLP.
RESULTS: Image contrast was reduced with the low-dose protocol, but this did not affect technical success or immediate pain relief. Mean DLP for all procedures decreased from 1458 ± 1022 to 199 ± 101 mGy · cm (P < .001). The range of radiologist-dependent DLP per procedure also was reduced significantly with the modified protocol. Selective nerve root blocks, lumbar injections, multiple injection sites, and the lack of prior imaging were each associated with a slightly higher DLP (<50 mGy · cm).
CONCLUSIONS: Radiation to patients undergoing CT-guided spinal injections can be decreased significantly without affecting outcome by reducing tube current, using axial acquisitions for short scan lengths, and eliminating nonessential imaging guidance. These measures also decrease variability in radiation doses between different practitioners and should be useful for other CT-guided procedures in radiology.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21920858      PMCID: PMC7966006          DOI: 10.3174/ajnr.A2634

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  20 in total

Review 1.  Low back pain.

Authors:  R A Deyo; J N Weinstein
Journal:  N Engl J Med       Date:  2001-02-01       Impact factor: 91.245

Review 2.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

Review 3.  Technical approaches to the optimisation of CT.

Authors:  Willi A Kalender; Stefanie Buchenau; Paul Deak; Markus Kellermeier; Oliver Langner; Marcel van Straten; Sabrina Vollmar; Sylvia Wilharm
Journal:  Phys Med       Date:  2008-03-10       Impact factor: 2.685

4.  Kerma area product method for effective dose estimation during lumbar epidural steroid injection procedures: phantom study.

Authors:  Sangroh Kim; Greta Toncheva; Colin Anderson-Evans; Billy K Huh; Linda Gray; Terry Yoshizumi
Journal:  AJR Am J Roentgenol       Date:  2009-06       Impact factor: 3.959

5.  Low-dose helical computed tomography (CT) in the perioperative workup of adolescent idiopathic scoliosis.

Authors:  Kasim Abul-Kasim; Angelica Overgaard; Pavel Maly; Acke Ohlin; Mikael Gunnarsson; Pia C Sundgren
Journal:  Eur Radiol       Date:  2008-09-23       Impact factor: 5.315

Review 6.  Optimizing radiation dose and image quality.

Authors:  Carlo Catalano; Marco Francone; Adriano Ascarelli; Matteo Mangia; Ilaria Iacucci; Roberto Passariello
Journal:  Eur Radiol       Date:  2007-12       Impact factor: 5.315

7.  A study of patient radiation doses in interventional radiological procedures.

Authors:  B J McParland
Journal:  Br J Radiol       Date:  1998-02       Impact factor: 3.039

8.  Reducing the radiation dose for CT colonography using adaptive statistical iterative reconstruction: A pilot study.

Authors:  Kristina T Flicek; Amy K Hara; Alvin C Silva; Qing Wu; Mary B Peter; C Daniel Johnson
Journal:  AJR Am J Roentgenol       Date:  2010-07       Impact factor: 3.959

Review 9.  Strategies for CT radiation dose optimization.

Authors:  Mannudeep K Kalra; Michael M Maher; Thomas L Toth; Leena M Hamberg; Michael A Blake; Jo-Anne Shepard; Sanjay Saini
Journal:  Radiology       Date:  2004-01-22       Impact factor: 11.105

10.  Radiation dose reduction strategy for CT protocols: successful implementation in neuroradiology section.

Authors:  Alice B Smith; William P Dillon; Benison C Lau; Robert Gould; Francis R Verdun; Edward B Lopez; Max Wintermark
Journal:  Radiology       Date:  2008-03-27       Impact factor: 11.105

View more
  18 in total

Review 1.  Navigational Tools for Interventional Radiology and Interventional Oncology Applications.

Authors:  Monzer A Chehab; Waleed Brinjikji; Alexander Copelan; Aradhana M Venkatesan
Journal:  Semin Intervent Radiol       Date:  2015-12       Impact factor: 1.513

2.  Real-time fusion-imaging in low back pain: a new navigation system for facet joint injections.

Authors:  Elena Massone; Davide Orlandi; Alberto Bellelli; Fabio Martino; Luca Cavagnaro; Matteo Formica; Pietro Caruso; Enzo Silvestri
Journal:  Radiol Med       Date:  2018-07-03       Impact factor: 3.469

3.  Radiation dose for 345 CT-guided interlaminar lumbar epidural steroid injections.

Authors:  A L Chang; A H Schoenfeld; A L Brook; T S Miller
Journal:  AJNR Am J Neuroradiol       Date:  2013-05-09       Impact factor: 3.825

4.  Radiation dose reduction in CT-guided spine biopsies does not reduce diagnostic yield.

Authors:  K A Shpilberg; B N Delman; L N Tanenbaum; S J Esses; R Subramaniam; A H Doshi
Journal:  AJNR Am J Neuroradiol       Date:  2014-07-17       Impact factor: 3.825

5.  Lateral decubitus positioning for cervical nerve root block using CT image guidance minimizes effective radiation dose and procedural time.

Authors:  T S Miller; K Fruauff; J Farinhas; D Pasquale; C Romano; A H Schoenfeld; A Brook
Journal:  AJNR Am J Neuroradiol       Date:  2012-06-28       Impact factor: 3.825

6.  CT-guided injection of a TRPV1 agonist around dorsal root ganglia decreases pain transmission in swine.

Authors:  Jacob D Brown; Maythem Saeed; Loi Do; Joao Braz; Allan I Basbaum; Michael J Iadarola; David M Wilson; William P Dillon
Journal:  Sci Transl Med       Date:  2015-09-16       Impact factor: 17.956

7.  Patient-specific image denoising for ultra-low-dose CT-guided lung biopsies.

Authors:  Michael Green; Edith M Marom; Eli Konen; Nahum Kiryati; Arnaldo Mayer
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-06-10       Impact factor: 2.924

8.  Standardization and optimization of CT protocols to achieve low dose.

Authors:  Sigal Trattner; Gregory D N Pearson; Cynthia Chin; Dianna D Cody; Rajiv Gupta; Christopher P Hess; Mannudeep K Kalra; James M Kofler; Mayil S Krishnam; Andrew J Einstein
Journal:  J Am Coll Radiol       Date:  2014-03       Impact factor: 5.532

9.  Instituting a Low-dose CT-guided Lung Biopsy Protocol.

Authors:  Kimberly G Kallianos; Brett M Elicker; Travis S Henry; Karen G Ordovas; Janet Nguyen; David M Naeger
Journal:  Acad Radiol       Date:  2016-06-14       Impact factor: 3.173

10.  CT-guided lumbar nerve root injections: are we using the correct radiation dose settings?

Authors:  J S Schauberger; P G Kranz; K R Choudhury; J D Eastwood; L Gray; J K Hoang
Journal:  AJNR Am J Neuroradiol       Date:  2012-05-10       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.