Literature DB >> 9579182

A study of patient radiation doses in interventional radiological procedures.

B J McParland1.   

Abstract

Patient radiation doses received during interventional radiological procedures can be significant. To aid in the establishment of reference dose levels, a patient dose survey has been conducted of such procedures. A total of 288 non-coronary procedures (177 classified as diagnostic and 111 as therapeutic) were accrued into the study. For each procedure, the fluoroscopy screening time and the fluoroscopic and digital radiographic dose-area products were recorded in a computer database. For example, median dose-area product values (due to fluoroscopy and digital radiography combined) of 24.2, 27.9, 69.6 and 74.7 Gy cm2 were obtained for nephrostomy, biliary stent removal/insertion, cerebral angiography and percutaneous transhepatic cholangiography procedures. While the effective dose is not an accurate measure of patient risk, it is convenient for comparing the radiological risks associated with various procedures. Effective doses were estimated from the total dose-area products. The respective median estimated effective dose values for the four procedures noted above were 3.9, 4.5, 7.0 and 12.0 mSv. While an infrequently performed procedure at this institution (n = 4 during this survey), the transjugular intrahepatic portosystemic shunt (TIPS) procedure had the greatest median dose-area product and effective dose values: 347 Gy cm2 and 55.5 mSv, respectively. Excluding the extreme case of TIPS, it was found that among commonly-performed procedures, those that are categorized as therapeutic do not necessarily present a statistically significant greater radiation risk than those which are diagnostic. Comparisons between dose-area product values obtained from this study are made with data from other interventional radiology patient dose surveys and reasons for some differences noted are discussed.

Entities:  

Mesh:

Year:  1998        PMID: 9579182     DOI: 10.1259/bjr.71.842.9579182

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  25 in total

1.  The impact of endoscopic retrograde cholangiopancreatography education on radiation exposure to experienced endoscopist: 'trainee effect'.

Authors:  Erkin Oztas; Erkan Parlak; Fahrettin Kucukay; Mehmet Arhan; Ulku Daglı; Digdem Ozer Etik; Fatih Oguz Onder; Tulay Olcer; Nurgul Sasmaz
Journal:  Dig Dis Sci       Date:  2012-05       Impact factor: 3.199

2.  A comparison of radiation exposure between diagnostic CTA and DSA examinations of cerebral and cervicocerebral vessels.

Authors:  A-L Manninen; J-M Isokangas; A Karttunen; T Siniluoto; M T Nieminen
Journal:  AJNR Am J Neuroradiol       Date:  2012-06-14       Impact factor: 3.825

3.  Risk of deterministic effects during endovascular aortic stent graft implantation.

Authors:  D Kuhelj; U Zdesar; V Jevtic; D Skrk; G Omahen; D Zontar; M Surlan; M Glusic; P Popovic; I J Kocijancic; V Salapura
Journal:  Br J Radiol       Date:  2010-11       Impact factor: 3.039

4.  Effect of physician training on fluoroscopy time during ERCP.

Authors:  Lance T Uradomo; Mark E Lustberg; Peter E Darwin
Journal:  Dig Dis Sci       Date:  2006-05-23       Impact factor: 3.199

5.  Radiation dose and risk from fluoroscopically guided percutaneous transluminal angioplasty and stenting in the abdominal region.

Authors:  John Stratakis; John Damilakis; Dimitrios Tsetis; Nicholas Gourtsoyiannis
Journal:  Eur Radiol       Date:  2007-03-27       Impact factor: 5.315

6.  Measurement of cerebral circulation times using dynamic whole-brain CT-angiography: feasibility and initial experience.

Authors:  Eberhard Siebert; Susanne Diekmann; Florian Masuhr; Hans-Christian Bauknecht; Stephan Schreiber; Randolf Klingebiel; Georg Bohner
Journal:  Neurol Sci       Date:  2011-09-22       Impact factor: 3.307

7.  Retrospective analysis of radiation exposure during endoscopic retrograde cholagiopancreatography: critical determinants.

Authors:  Edward Kim; Mark McLoughlin; Eric C Lam; Jack Amar; Michael Byrne; Jennifer Telford; Robert Enns
Journal:  Can J Gastroenterol       Date:  2011-10       Impact factor: 3.522

8.  Torsional dynamics of steerable needles: modeling and fluoroscopic guidance.

Authors:  John P Swensen; MingDe Lin; Allison M Okamura; Noah J Cowan
Journal:  IEEE Trans Biomed Eng       Date:  2014-05-21       Impact factor: 4.538

9.  Effective-dose estimation in interventional radiological procedures.

Authors:  Maria D Falco; Salvatore Masala; Matteo Stefanini; Paolo Bagalà; Daniele Morosetti; Eros Calabria; Alessia Tonnetti; Gianluca Verona-Rinati
Journal:  Radiol Phys Technol       Date:  2018-03-08

10.  Diagnosis of double splenic artery pseudoaneurysm: CT scan versus angiography.

Authors:  Sanaa Badour; Deborah Mukherji; Walid Faraj; Ali Haydar
Journal:  BMJ Case Rep       Date:  2015-04-28
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.