| Literature DB >> 21864359 |
Erin E Kuffel1, Scott E Crouter, Jere D Haas, Edward A Frongillo, David R Bassett.
Abstract
BACKGROUND: Objective measurement of physical activity remains an important challenge. For wearable monitors such as accelerometer-based physical activity monitors, more accurate methods are needed to convert activity counts into energy expenditure (EE).Entities:
Mesh:
Year: 2011 PMID: 21864359 PMCID: PMC3170241 DOI: 10.1186/1479-5868-8-92
Source DB: PubMed Journal: Int J Behav Nutr Phys Act ISSN: 1479-5868 Impact factor: 6.457
Description of the differences between the 2006 Crouter 2-Regression Model (2006 C2RM) and Refined Crouter 2-Regression Model (Refined C2RM)
| Model | Inactivity Threshold | Determination of Variability | Determination of CV** | If CV ≤10% | If CV > 10% |
|---|---|---|---|---|---|
| 2006 C2RM | 50 counts min-1 | six consecutive 10-s epochs | CV among 6 consecutive 10-s epochs | Walk/run equation | Intermittent lifestyle equation |
| Refined C2RM | 8 counts per 10 s | Examines all combinations of surrounding five 10-s epochs* | Lowest CV out of all possible combinations | Walk/run equation | Intermittent lifestyle equation |
*Examination includes 10-s epoch of interest and five before, 10-s epoch of interest and four epochs before and one after, etc.
**CV: coefficient of variation
Figure 1Mean EE for each minute during a self-selected walking pace. Mean measured (Cosmed K4b2) and predicted (2006 Crouter 2-Regression model (C2RM) and refined C2RM) energy expenditure for each minute of the: A) 0-s condition; B) 20-s condition; and C) 40-s condition during walking at a self-selected pace.
Energy expenditure for the Cosmed K4b2, 2006 Crouter 2-Regression Model (2006 C2RM), and Refined Crouter 2-Regression Model (Refined C2RM) for each walking condition
| Condition | Cosmed K4b2 | 2006 C2RM | Refined C2RM |
|---|---|---|---|
| All Conditions | 3.6 (0.7) | 4.0 (0.5)* | 3.5 (0.5) |
| 20-s | 3.3 (0.7) | 4.1 (0.9)* | 3.4 (0.5) |
| 40-s | 3.6 (1.0) | 4.0 (0.8)* | 3.5 (0.6) |
*Significantly different from measured kcal kg-1 hr-1 and refined C2RM (P < 0.02).
Energy expenditure expressed as kcal kg-1 hr-1 (Mean (SD)).
Figure 2Bland-Altman plots depicting error scores for the 2006 C2RM and the refined C2RM. Bland-Altman plots depicting error scores (actual minus prediction) for each minute of walking, including transitional minutes for the 2006 Crouter 2-Regression Model (C2RM): A) 0-s condition, B) 20-s condition, C) 40-s condition, and the refined C2RM: D) 0-s condition, E) 20-s condition, and F) 40-s condition. The solid line represents the mean bias and the dashed lines represent the 95% prediction interval. Data points below zero signify an overestimation, while data points above zero signify an underestimation.