Literature DB >> 20142778

Validation of the ActiGraph two-regression model for predicting energy expenditure.

Megan P Rothney1, Robert J Brychta, Natalie N Meade, Kong Y Chen, Maciej S Buchowski.   

Abstract

PURPOSE: The purpose of this study was to validate a two-regression model for predicting energy expenditure (EE) from ActiGraph GT1M accelerometer-generated activity counts using a whole-room indirect calorimeter and the doubly labeled water (DLW) technique. We also investigated if a low-pass filter (LPF) approach would improve the model's accuracy in the minute-to-minute EE prediction.
METHODS: Thirty-four healthy volunteers (age = 20-67 yr, body mass index = 19.3-52.1 kg.m) spent approximately 24 h in a room calorimeter while wearing a GT1M monitor and performed structured and self-selected activities followed by overnight sleep. The EE predicted by the models and expressed in metabolic equivalents (MET-minutes) during waking times was compared with the room calorimeter-measured EE. A subset of volunteers (n = 22) completed a 14-d DLW protocol in free living while wearing an ActiGraph. The average daily EE predicted by the models (MET-minutes) was compared with the DLW.
RESULTS: Compared with the room calorimeter, the two-regression model overpredicted EE by 10.2% +/- 11.4% (1282 +/- 125 and 1174 +/- 152 MET.min, P < 0.001) and time spent in moderate physical activity (PA) by 36.9 +/- 46.0 min while underestimating the time spent in light PA by -48.3 +/- 55.0 min (P < 0.05). The LPF reduced the squared and mean absolute error in the EE prediction (P < 0.05) but not the prediction error in time spent in moderate or light PA (both P > 0.05). The EE measured by DLW (2108 +/- 358 MET.min.d) and predicted by both filtered and unfiltered models (2104 +/- 218 and 2192 +/- 228 MET.min.d, respectively) were similar (P > 0.05).
CONCLUSIONS: The two-regression model with LPF showed good agreement with total EE measured using room calorimeter and DLW. However, the individual variability in assessing time spent in sedentary, low, and moderate PA intensities and related EE remains significant.

Entities:  

Mesh:

Year:  2010        PMID: 20142778      PMCID: PMC2919650          DOI: 10.1249/MSS.0b013e3181d5a984

Source DB:  PubMed          Journal:  Med Sci Sports Exerc        ISSN: 0195-9131            Impact factor:   5.411


  26 in total

1.  Assessment of physical activity with the Computer Science and Applications, Inc., accelerometer: laboratory versus field validation.

Authors:  J F Nichols; C G Morgan; L E Chabot; J F Sallis; K J Calfas
Journal:  Res Q Exerc Sport       Date:  2000-03       Impact factor: 2.500

2.  Estimation of energy expenditure using CSA accelerometers at hip and wrist sites.

Authors:  A M Swartz; S J Strath; D R Bassett; W L O'Brien; G A King; B E Ainsworth
Journal:  Med Sci Sports Exerc       Date:  2000-09       Impact factor: 5.411

3.  Validity of accelerometry for the assessment of moderate intensity physical activity in the field.

Authors:  D Hendelman; K Miller; C Baggett; E Debold; P Freedson
Journal:  Med Sci Sports Exerc       Date:  2000-09       Impact factor: 5.411

4.  Comparison of MTI accelerometer cut-points for predicting time spent in physical activity.

Authors:  S J Strath; D R Bassett; A M Swartz
Journal:  Int J Sports Med       Date:  2003-05       Impact factor: 3.118

5.  Improving energy expenditure estimation for physical activity.

Authors:  Kuan Zhang; F Xavier Pi-Sunyer; Carol N Boozer
Journal:  Med Sci Sports Exerc       Date:  2004-05       Impact factor: 5.411

6.  Energy expenditure by doubly labeled water: validation in humans and proposed calculation.

Authors:  D A Schoeller; E Ravussin; Y Schutz; K J Acheson; P Baertschi; E Jéquier
Journal:  Am J Physiol       Date:  1986-05

7.  Stable isotopic methods for measuring energy expenditure. Applications of the doubly-labelled-water (2H2(18)O) method in free-living adults.

Authors:  A M Prentice
Journal:  Proc Nutr Soc       Date:  1988-09       Impact factor: 6.297

8.  Regression analysis.

Authors:  J M Bland; D J Altman
Journal:  Lancet       Date:  1986-04-19       Impact factor: 79.321

9.  Modification of a whole room indirect calorimeter for measurement of rapid changes in energy expenditure.

Authors:  M Sun; G W Reed; J O Hill
Journal:  J Appl Physiol (1985)       Date:  1994-06

10.  Improving energy expenditure estimation by using a triaxial accelerometer.

Authors:  K Y Chen; M Sun
Journal:  J Appl Physiol (1985)       Date:  1997-12
View more
  26 in total

1.  Use of a two-regression model for estimating energy expenditure in children.

Authors:  Scott E Crouter; Magdalene Horton; David R Bassett
Journal:  Med Sci Sports Exerc       Date:  2012-06       Impact factor: 5.411

2.  Fatigability as a function of physical activity energy expenditure in older adults.

Authors:  Maciej S Buchowski; Sandra F Simmons; Lauren E Whitaker; James Powers; Linda Beuscher; Leena Choi; T Alp Ikizler; Kong Chen; John F Shnelle
Journal:  Age (Dordr)       Date:  2011-11-24

3.  Effect of BMI on prediction of accelerometry-based energy expenditure in youth.

Authors:  Joshua Warolin; Amanda R Carrico; Lauren E Whitaker; Li Wang; Kong Y Chen; Sari Acra; Maciej S Buchowski
Journal:  Med Sci Sports Exerc       Date:  2012-12       Impact factor: 5.411

Review 4.  Physical activity after total knee arthroplasty: A critical review.

Authors:  Roger J Paxton; Edward L Melanson; Jennifer E Stevens-Lapsley; Cory L Christiansen
Journal:  World J Orthop       Date:  2015-09-18

5.  Objective measurement of free-living physical activity (performance) in lumbar spinal stenosis: are physical activity guidelines being met?

Authors:  Justin Norden; Matthew Smuck; Aman Sinha; Richard Hu; Christy Tomkins-Lane
Journal:  Spine J       Date:  2016-10-25       Impact factor: 4.166

6.  Validity of ActiGraph 2-regression model, Matthews cut-points, and NHANES cut-points for assessing free-living physical activity.

Authors:  Scott E Crouter; Diane M DellaValle; Jere D Haas; Edward A Frongillo; David R Bassett
Journal:  J Phys Act Health       Date:  2012-09-11

7.  Validity of physical activity measures in individuals after total knee arthroplasty.

Authors:  Gustavo J Almeida; David M Wert; Kelly S Brower; Sara R Piva
Journal:  Arch Phys Med Rehabil       Date:  2014-10-31       Impact factor: 3.966

8.  Validation of accelerometer wear and nonwear time classification algorithm.

Authors:  Leena Choi; Zhouwen Liu; Charles E Matthews; Maciej S Buchowski
Journal:  Med Sci Sports Exerc       Date:  2011-02       Impact factor: 5.411

9.  Comparisons of prediction equations for estimating energy expenditure in youth.

Authors:  Youngwon Kim; Scott E Crouter; Jung-Min Lee; Phillip M Dixon; Glenn A Gaesser; Gregory J Welk
Journal:  J Sci Med Sport       Date:  2014-10-18       Impact factor: 4.319

Review 10.  Accelerometer Data Collection and Processing Criteria to Assess Physical Activity and Other Outcomes: A Systematic Review and Practical Considerations.

Authors:  Jairo H Migueles; Cristina Cadenas-Sanchez; Ulf Ekelund; Christine Delisle Nyström; Jose Mora-Gonzalez; Marie Löf; Idoia Labayen; Jonatan R Ruiz; Francisco B Ortega
Journal:  Sports Med       Date:  2017-09       Impact factor: 11.136

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.