Literature DB >> 21848273

Optimization and evaluation of a sheathless capillary electrophoresis-electrospray ionization mass spectrometry platform for peptide analysis: comparison to liquid chromatography-electrospray ionization mass spectrometry.

Klaus Faserl1, Bettina Sarg, Leopold Kremser, Herbert Lindner.   

Abstract

In this study we have evaluated the suitability of a sheathless capillary electrophoresis-electrospray ionization mass spectrometry (CE-ESI-MS) interface with a porous tip as the nanospray emitter for use in peptide analysis. A positively charged capillary coating and 0.1% formic acid as background electrolyte were used for separation upstream from mass spectrometry characterization. The influence of the distance between emitter tip and MS inlet, ESI voltage applied, and of the electroosmotic flow (EOF) on electrospray performance and efficiency of the system was investigated in detail. Under optimized conditions, less than 30 amol of a model peptide (angiotensin I) was required for a detection in the base peak electropherogram and positive identification via tandem MS. Three different cationic capillary coatings were investigated for stability, resolution, and EOF and were found to enable reproducible separations by CE-ESI-MS. After optimizing MS settings, the effectiveness of the CE-ESI-MS method developed was compared with a state-of-the-art nano-liquid chromatography (LC)-ESI-MS method by analyzing Arg-C-digested rat testis linker histones with both systems. With comparable amounts of sample applied, the number of identified peptides increased by more than 60% when using CE-ESI-MS. We found that low molecular mass peptides (below 1400 Da) were preferentially identified by CE-ESI-MS, since this group of peptides poorly interacted with the reversed-phase material in the nano-LC system. Finally, total analysis time in LC-ESI-MS for three runs including equilibration was nearly 4 times longer than that of CE-ESI-MS: 246 versus 66 min.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21848273     DOI: 10.1021/ac2010372

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  53 in total

1.  Comparing and combining capillary electrophoresis electrospray ionization mass spectrometry and nano-liquid chromatography electrospray ionization mass spectrometry for the characterization of post-translationally modified histones.

Authors:  Bettina Sarg; Klaus Faserl; Leopold Kremser; Bernhard Halfinger; Roberto Sebastiano; Herbert H Lindner
Journal:  Mol Cell Proteomics       Date:  2013-05-29       Impact factor: 5.911

2.  Capillary Zone Electrophoresis-Tandem Mass Spectrometry for Large-Scale Phosphoproteomics with the Production of over 11,000 Phosphopeptides from the Colon Carcinoma HCT116 Cell Line.

Authors:  Daoyang Chen; Katelyn R Ludwig; Oleg V Krokhin; Vic Spicer; Zhichang Yang; Xiaojing Shen; Amanda B Hummon; Liangliang Sun
Journal:  Anal Chem       Date:  2019-01-23       Impact factor: 6.986

Review 3.  Recent advances in coupling capillary electrophoresis-based separation techniques to ESI and MALDI-MS.

Authors:  Xuefei Zhong; Zichuan Zhang; Shan Jiang; Lingjun Li
Journal:  Electrophoresis       Date:  2013-12-05       Impact factor: 3.535

4.  Ultrasensitive and fast bottom-up analysis of femtogram amounts of complex proteome digests.

Authors:  Liangliang Sun; Guijie Zhu; Yimeng Zhao; Xiaojing Yan; Si Mou; Norman J Dovichi
Journal:  Angew Chem Int Ed Engl       Date:  2013-10-31       Impact factor: 15.336

Review 5.  Protein analysis by shotgun/bottom-up proteomics.

Authors:  Yaoyang Zhang; Bryan R Fonslow; Bing Shan; Moon-Chang Baek; John R Yates
Journal:  Chem Rev       Date:  2013-02-26       Impact factor: 60.622

6.  Capillary electrophoresis with Orbitrap-Velos mass spectrometry detection.

Authors:  Roza Wojcik; Yihan Li; Michael J Maccoss; Norman J Dovichi
Journal:  Talanta       Date:  2011-11-29       Impact factor: 6.057

7.  Stable, reproducible, and automated capillary zone electrophoresis-tandem mass spectrometry system with an electrokinetically pumped sheath-flow nanospray interface.

Authors:  Guijie Zhu; Liangliang Sun; Xiaojing Yan; Norman J Dovichi
Journal:  Anal Chim Acta       Date:  2013-12-07       Impact factor: 6.558

Review 8.  Capillary zone electrophoresis as a tool for bottom-up protein analysis.

Authors:  Roza Wojcik; Guijie Zhu; Zhenbin Zhang; Xiaojing Yan; Yimeng Zhao; Liangliang Sun; Matthew M Champion; Norman J Dovichi
Journal:  Bioanalysis       Date:  2015-12-10       Impact factor: 2.681

9.  CZE-ESI-MS/MS system for analysis of subnanogram amounts of tryptic digests of a cellular homogenate.

Authors:  Liangliang Sun; Guijie Zhu; Yihan Li; Roza Wojcik; Ping Yang; Norman J Dovichi
Journal:  Proteomics       Date:  2012-08-29       Impact factor: 3.984

10.  Evaluation of a microchip electrophoresis-mass spectrometry platform deploying a pressure-driven make-up flow.

Authors:  Xiangtang Li; Shulin Zhao; Yi-Ming Liu
Journal:  J Chromatogr A       Date:  2013-02-17       Impact factor: 4.759

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.