Literature DB >> 22888077

CZE-ESI-MS/MS system for analysis of subnanogram amounts of tryptic digests of a cellular homogenate.

Liangliang Sun1, Guijie Zhu, Yihan Li, Roza Wojcik, Ping Yang, Norman J Dovichi.   

Abstract

We report the performance of capillary zone electrophoresis coupled with an electrokinetically pumped electrospray interface and an Orbitrap-Velos mass spectrometer for high sensitivity protein analysis. We first investigated the system for quantitation of the tryptic digest of BSA. The system produced outstanding linearity with respect to peak height, number of peptide IDs, and spectral counts across the range of 12 nM to 750 nM (60 amol to 3.5 fmol) of BSA injected. One peptide produced a detection limit of 0.3 nM (1.5 amol) injected. We also analyzed 700 pg of a tryptic digest prepared from a RAW264.7 cell lysate; ten proteins were identified in triplicate analyses after filtering the data with peptide confidence value as high. This sample size corresponds to the protein content of approximately ten eukaryotic cells.
© 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22888077      PMCID: PMC3670668          DOI: 10.1002/pmic.201200100

Source DB:  PubMed          Journal:  Proteomics        ISSN: 1615-9853            Impact factor:   3.984


  27 in total

1.  Correlating cell cycle with metabolism in single cells: combination of image and metabolic cytometry.

Authors:  S N Krylov; Z Zhang; N W Chan; E Arriaga; M M Palcic; N J Dovichi
Journal:  Cytometry       Date:  1999-09-01

Review 2.  Capillary electrophoresis for the analysis of biopolymers.

Authors:  S N Krylov; N J Dovichi
Journal:  Anal Chem       Date:  2000-06-15       Impact factor: 6.986

3.  On-line protein digestion and peptide mapping by capillary electrophoresis with post-column labeling for laser-induced fluorescence detection.

Authors:  Mingliang Ye; Shen Hu; Regine M Schoenherr; Norman J Dovichi
Journal:  Electrophoresis       Date:  2004-05       Impact factor: 3.535

4.  Capillary electrophoresis.

Authors:  Matthew Geiger; Amy L Hogerton; Michael T Bowser
Journal:  Anal Chem       Date:  2011-12-28       Impact factor: 6.986

5.  Performance of a sheathless porous tip sprayer for capillary electrophoresis-electrospray ionization-mass spectrometry of intact proteins.

Authors:  Rob Haselberg; Chitra K Ratnayake; Gerhardus J de Jong; Govert W Somsen
Journal:  J Chromatogr A       Date:  2010-11-26       Impact factor: 4.759

6.  A low-makeup beveled tip capillary electrophoresis /electrospray ionization mass spectrometry interface for micellar electrokinetic chromatography and nonvolatile buffer capillary electrophoresis.

Authors:  Mei-Chun Tseng; Yet-Ran Chen; Guor-Rong Her
Journal:  Anal Chem       Date:  2004-11-01       Impact factor: 6.986

7.  A sheath-flow nanospray interface for capillary electrophoresis/mass spectrometry.

Authors:  Charles C Liu; Jianzhong Zhang; Norman J Dovichi
Journal:  Rapid Commun Mass Spectrom       Date:  2005       Impact factor: 2.419

8.  CE-microreactor-CE-MS/MS for protein analysis.

Authors:  Regine M Schoenherr; Mingliang Ye; Michael Vannatta; Norman J Dovichi
Journal:  Anal Chem       Date:  2007-02-13       Impact factor: 6.986

9.  Simplifying CE-MS operation. 2. Interfacing low-flow separation techniques to mass spectrometry using a porous tip.

Authors:  Mehdi Moini
Journal:  Anal Chem       Date:  2007-04-21       Impact factor: 6.986

10.  Decoupling CE and ESI for a more robust interface with MS.

Authors:  E Jane Maxwell; Xuefei Zhong; Hong Zhang; Nikita van Zeijl; David D Y Chen
Journal:  Electrophoresis       Date:  2010-04       Impact factor: 3.595

View more
  20 in total

Review 1.  Recent advances in coupling capillary electrophoresis-based separation techniques to ESI and MALDI-MS.

Authors:  Xuefei Zhong; Zichuan Zhang; Shan Jiang; Lingjun Li
Journal:  Electrophoresis       Date:  2013-12-05       Impact factor: 3.535

2.  Ultrasensitive and fast bottom-up analysis of femtogram amounts of complex proteome digests.

Authors:  Liangliang Sun; Guijie Zhu; Yimeng Zhao; Xiaojing Yan; Si Mou; Norman J Dovichi
Journal:  Angew Chem Int Ed Engl       Date:  2013-10-31       Impact factor: 15.336

3.  Comparison of the LTQ-Orbitrap Velos and the Q-Exactive for proteomic analysis of 1-1000 ng RAW 264.7 cell lysate digests.

Authors:  Liangliang Sun; Guijie Zhu; Norman J Dovichi
Journal:  Rapid Commun Mass Spectrom       Date:  2013-01-15       Impact factor: 2.419

4.  Coupling capillary zone electrophoresis with electron transfer dissociation and activated ion electron transfer dissociation for top-down proteomics.

Authors:  Yimeng Zhao; Nicholas M Riley; Liangliang Sun; Alexander S Hebert; Xiaojing Yan; Michael S Westphall; Matthew J P Rush; Guijie Zhu; Matthew M Champion; Felix Mba Medie; Patricia A DiGiuseppe Champion; Joshua J Coon; Norman J Dovichi
Journal:  Anal Chem       Date:  2015-05-06       Impact factor: 6.986

5.  Bottom-up proteome analysis of E. coli using capillary zone electrophoresis-tandem mass spectrometry with an electrokinetic sheath-flow electrospray interface.

Authors:  Xiaojing Yan; David C Essaka; Liangliang Sun; Guijie Zhu; Norman J Dovichi
Journal:  Proteomics       Date:  2013-08-01       Impact factor: 3.984

6.  Improvement of Mitochondria Extract from Saccharomyces cerevisiae Characterization in Shotgun Proteomics Using Sheathless Capillary Electrophoresis Coupled to Tandem Mass Spectrometry.

Authors:  Marianne Ibrahim; Rabah Gahoual; Ludovic Enkler; Hubert Dominique Becker; Johana Chicher; Philippe Hammann; Yannis-Nicolas François; Lauriane Kuhn; Emmanuelle Leize-Wagner
Journal:  J Chromatogr Sci       Date:  2016-02-08       Impact factor: 1.618

7.  Capillary isoelectric focusing-tandem mass spectrometry and reversed-phase liquid chromatography-tandem mass spectrometry for quantitative proteomic analysis of differentiating PC12 cells by eight-plex isobaric tags for relative and absolute quantification.

Authors:  Guijie Zhu; Liangliang Sun; Richard B Keithley; Norman J Dovichi
Journal:  Anal Chem       Date:  2013-07-18       Impact factor: 6.986

8.  Stable, reproducible, and automated capillary zone electrophoresis-tandem mass spectrometry system with an electrokinetically pumped sheath-flow nanospray interface.

Authors:  Guijie Zhu; Liangliang Sun; Xiaojing Yan; Norman J Dovichi
Journal:  Anal Chim Acta       Date:  2013-12-07       Impact factor: 6.558

9.  Capillary zone electrophoresis-multiple reaction monitoring from 100 pg of RAW 264.7 cell lysate digest.

Authors:  Liangliang Sun; Yihan Li; Matthew M Champion; Guijie Zhu; Roza Wojcik; Norman J Dovichi
Journal:  Analyst       Date:  2013-06-07       Impact factor: 4.616

10.  Capillary zone electrophoresis-electrospray ionization-tandem mass spectrometry for quantitative parallel reaction monitoring of peptide abundance and single-shot proteomic analysis of a human cell line.

Authors:  Liangliang Sun; Guijie Zhu; Si Mou; Yimeng Zhao; Matthew M Champion; Norman J Dovichi
Journal:  J Chromatogr A       Date:  2014-07-17       Impact factor: 4.759

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.