Literature DB >> 24439510

Stable, reproducible, and automated capillary zone electrophoresis-tandem mass spectrometry system with an electrokinetically pumped sheath-flow nanospray interface.

Guijie Zhu1, Liangliang Sun1, Xiaojing Yan1, Norman J Dovichi2.   

Abstract

A PrinCE autosampler was coupled to a Q-Exactive mass spectrometer by an electrokinetically pumped sheath-flow nanospray interface to perform automated capillary zone electrophoresis-electrospray ionization-tandem mass spectrometry (CZE-ESI-MS/MS). 20ng aliquots of an Escherichia coli digest were injected to evaluate the system. Eight sequential injections over an 8-h period identified 1115±70 (relative standard deviation, RSD=6%) peptides and 270±8 (RSD=3%) proteins per run. The average RSDs of migration time, peak intensity, and peak area were 3%, 24% and 19%, respectively, for 340 peptides with high intensity. This is the first report of an automated CZE-ESI-MS/MS system using the electrokinetically pumped sheath-flow nanospray interface. The results demonstrate that this system is capable of reproducibly identifying over 1000 peptides from an E. coli tryptic digest in a 1-h analysis time.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Capillary zone electrophoresis; Proteomics

Mesh:

Substances:

Year:  2013        PMID: 24439510      PMCID: PMC3918410          DOI: 10.1016/j.aca.2013.11.057

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  24 in total

Review 1.  Capillary electrophoresis for the analysis of biopolymers.

Authors:  S N Krylov; N J Dovichi
Journal:  Anal Chem       Date:  2000-06-15       Impact factor: 6.986

2.  Empirical statistical model to estimate the accuracy of peptide identifications made by MS/MS and database search.

Authors:  Andrew Keller; Alexey I Nesvizhskii; Eugene Kolker; Ruedi Aebersold
Journal:  Anal Chem       Date:  2002-10-15       Impact factor: 6.986

3.  Capillary electrophoresis.

Authors:  Matthew Geiger; Amy L Hogerton; Michael T Bowser
Journal:  Anal Chem       Date:  2011-12-28       Impact factor: 6.986

4.  Simplifying CE-MS operation. 2. Interfacing low-flow separation techniques to mass spectrometry using a porous tip.

Authors:  Mehdi Moini
Journal:  Anal Chem       Date:  2007-04-21       Impact factor: 6.986

5.  Mass transport in a micro flow-through vial of a junction-at-the-tip capillary electrophoresis-mass spectrometry interface.

Authors:  Xuefei Zhong; E Jane Maxwell; David D Y Chen
Journal:  Anal Chem       Date:  2011-05-17       Impact factor: 6.986

6.  Optimization and evaluation of a sheathless capillary electrophoresis-electrospray ionization mass spectrometry platform for peptide analysis: comparison to liquid chromatography-electrospray ionization mass spectrometry.

Authors:  Klaus Faserl; Bettina Sarg; Leopold Kremser; Herbert Lindner
Journal:  Anal Chem       Date:  2011-09-01       Impact factor: 6.986

7.  CZE-ESI-MS/MS system for analysis of subnanogram amounts of tryptic digests of a cellular homogenate.

Authors:  Liangliang Sun; Guijie Zhu; Yihan Li; Roza Wojcik; Ping Yang; Norman J Dovichi
Journal:  Proteomics       Date:  2012-08-29       Impact factor: 3.984

8.  Capillary zone electrophoresis-multiple reaction monitoring from 100 pg of RAW 264.7 cell lysate digest.

Authors:  Liangliang Sun; Yihan Li; Matthew M Champion; Guijie Zhu; Roza Wojcik; Norman J Dovichi
Journal:  Analyst       Date:  2013-06-07       Impact factor: 4.616

9.  Single-shot proteomics using capillary zone electrophoresis-electrospray ionization-tandem mass spectrometry with production of more than 1250 Escherichia coli peptide identifications in a 50 min separation.

Authors:  Guijie Zhu; Liangliang Sun; Xiaojing Yan; Norman J Dovichi
Journal:  Anal Chem       Date:  2013-02-13       Impact factor: 6.986

Review 10.  High sensitivity capillary zone electrophoresis-electrospray ionization-tandem mass spectrometry for the rapid analysis of complex proteomes.

Authors:  Liangliang Sun; Guijie Zhu; Xiaojing Yan; Norman J Dovichi
Journal:  Curr Opin Chem Biol       Date:  2013-08-01       Impact factor: 8.822

View more
  8 in total

1.  Third-generation electrokinetically pumped sheath-flow nanospray interface with improved stability and sensitivity for automated capillary zone electrophoresis-mass spectrometry analysis of complex proteome digests.

Authors:  Liangliang Sun; Guijie Zhu; Zhenbin Zhang; Si Mou; Norman J Dovichi
Journal:  J Proteome Res       Date:  2015-03-27       Impact factor: 4.466

2.  Over 4100 protein identifications from a Xenopus laevis fertilized egg digest using reversed-phase chromatographic prefractionation followed by capillary zone electrophoresis-electrospray ionization-tandem mass spectrometry analysis.

Authors:  Xiaojing Yan; Liangliang Sun; Guijie Zhu; Olivia F Cox; Norman J Dovichi
Journal:  Proteomics       Date:  2016-12       Impact factor: 3.984

3.  Capillary Electrophoresis-Mass Spectrometry (CE-MS) by Sheath-Flow Nanospray Interface and Its Use in Biopharmaceutical Applications.

Authors:  Mei Han; Richard Smith; Dan A Rock
Journal:  Methods Mol Biol       Date:  2022

4.  High speed capillary zone electrophoresis-mass spectrometry via an electrokinetically pumped sheath flow interface for rapid analysis of amino acids and a protein digest.

Authors:  Nicole M Schiavone; Scott A Sarver; Liangliang Sun; Roza Wojcik; Norman J Dovichi
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2015-04-09       Impact factor: 3.205

Review 5.  Dynamic pH junction preconcentration in capillary electrophoresis- electrospray ionization-mass spectrometry for proteomics analysis.

Authors:  Guijie Zhu; Liangliang Sun; Norman J Dovichi
Journal:  Analyst       Date:  2016-07-27       Impact factor: 4.616

6.  Capillary zone electrophoresis-electrospray ionization-tandem mass spectrometry for quantitative parallel reaction monitoring of peptide abundance and single-shot proteomic analysis of a human cell line.

Authors:  Liangliang Sun; Guijie Zhu; Si Mou; Yimeng Zhao; Matthew M Champion; Norman J Dovichi
Journal:  J Chromatogr A       Date:  2014-07-17       Impact factor: 4.759

Review 7.  Proteomic challenges: sample preparation techniques for microgram-quantity protein analysis from biological samples.

Authors:  Peter Feist; Amanda B Hummon
Journal:  Int J Mol Sci       Date:  2015-02-05       Impact factor: 5.923

8.  Bottom-up proteomics of Escherichia coli using dynamic pH junction preconcentration and capillary zone electrophoresis-electrospray ionization-tandem mass spectrometry.

Authors:  Guijie Zhu; Liangliang Sun; Xiaojing Yan; Norman J Dovichi
Journal:  Anal Chem       Date:  2014-06-09       Impact factor: 6.986

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.