Literature DB >> 23473508

Evaluation of a microchip electrophoresis-mass spectrometry platform deploying a pressure-driven make-up flow.

Xiangtang Li1, Shulin Zhao, Yi-Ming Liu.   

Abstract

Integration of a pressure-driven make-up flow (MUF) into a microchip electrophoresis (MCE) platform in order to facilitate its coupling with electrospray ionization-mass spectrometric detection (ESI-MS) is described. In the glass/PDMS hybrid microchip, a MUF channel was made to intersect with the MCE separation channel at an angle of 45°. The MUF was generated by a syringe pump. Microscopic image results from simulation studies showed that the pressure-driven MUF and the potential-driven electroosmotic flow in the MCE separation channel could be run separately without interfering with each other and mixed well at the joint point by adjusting either the MUF flow rate or the potential applied for MCE separation. The MUF had several desirable functions, including making the start of electrospray easy and cleaning the nanoESI emitter continuously when not spraying. High separation efficiency was achieved with the proposed MCE-nanopan class="Disease">ESI-MS system in separating an amino acid mixture containing glutamine, serine, threonine, phenylalanine, and glutamic acid. All of them were baseline separated from each other within 3 min. Plate numbers of >10,000 (on a 2.5 cm MCE separation channel) were obtained. The analytical platform also showed a linear response for quantification of DOPA with a detection limit (S/N=3) of 0.10 μM. In addition, on-line derivatization of MCE elutes in order to enhance MS detection sensitivity was easily carried out by adding the tagging reagent into the MUF. These results indicated that the present system might have a good potential in MCE-MS applications.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23473508      PMCID: PMC3602291          DOI: 10.1016/j.chroma.2013.02.031

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  26 in total

1.  Electrospray device for coupling microscale separations and other miniaturized devices with electrospray mass spectrometry.

Authors:  T Wachs; J Henion
Journal:  Anal Chem       Date:  2001-02-01       Impact factor: 6.986

2.  Robust and simple interface for microchip electrophoresis-mass spectrometry.

Authors:  Yuji Tachibana; Koji Otsuka; Shigeru Terabe; Akihiro Arai; Koichi Suzuki; Shin Nakamura
Journal:  J Chromatogr A       Date:  2003-09-05       Impact factor: 4.759

Review 3.  Chip-based separation devices coupled to mass spectrometry.

Authors:  Stefan Ohla; Detlev Belder
Journal:  Curr Opin Chem Biol       Date:  2012-06-05       Impact factor: 8.822

4.  A sheath-flow nanoelectrospray interface of microchip electrophoresis MS for glycoprotein and glycopeptide analysis.

Authors:  Xiuli Mao; Ivan K Chu; Bingcheng Lin
Journal:  Electrophoresis       Date:  2006-12       Impact factor: 3.535

5.  Chip-based quantitative capillary electrophoresis/mass spectrometry determination of drugs in human plasma.

Authors:  Y Deng; H Zhang; J Henion
Journal:  Anal Chem       Date:  2001-04-01       Impact factor: 6.986

6.  Fully microfabricated and integrated SU-8-based capillary electrophoresis-electrospray ionization microchips for mass spectrometry.

Authors:  Tiina Sikanen; Santeri Tuomikoski; Raimo A Ketola; Risto Kostiainen; Sami Franssila; Tapio Kotiaho
Journal:  Anal Chem       Date:  2007-10-31       Impact factor: 6.986

7.  Micro total analysis systems: latest achievements.

Authors:  Jonathan West; Marco Becker; Sven Tombrink; Andreas Manz
Journal:  Anal Chem       Date:  2008-05-23       Impact factor: 6.986

8.  Coupling a microchip with electrospray ionization quadrupole time-of-flight mass spectrometer for peptide separation and identification.

Authors:  Hai-Fang Li; Jiangjiang Liu; Zongwei Cai; Jin-Ming Lin
Journal:  Electrophoresis       Date:  2008-05       Impact factor: 3.535

9.  Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane).

Authors:  D C Duffy; J C McDonald; O J Schueller; G M Whitesides
Journal:  Anal Chem       Date:  1998-12-01       Impact factor: 6.986

10.  Chiral capillary electrophoresis-mass spectrometry of tetrahydroisoquinoline-derived neurotoxins: observation of complex stereoisomerism.

Authors:  Hao Wu; Baiqing Yuan; Yi-Ming Liu
Journal:  J Chromatogr A       Date:  2011-03-21       Impact factor: 4.759

View more
  3 in total

1.  D-serine uptake and release in PC-12 cells measured by chiral microchip electrophoresis-mass spectrometry.

Authors:  Xiangtang Li; Cassandra McCullum; Shulin Zhao; Hankun Hu; Yi-Ming Liu
Journal:  ACS Chem Neurosci       Date:  2015-02-03       Impact factor: 4.418

2.  A microchip electrophoresis-mass spectrometric platform with double cell lysis nano-electrodes for automated single cell analysis.

Authors:  Xiangtang Li; Shulin Zhao; Hankun Hu; Yi-Ming Liu
Journal:  J Chromatogr A       Date:  2016-05-06       Impact factor: 4.759

3.  Microfluidic Platform with In-Chip Electrophoresis Coupled to Mass Spectrometry for Monitoring Neurochemical Release from Nerve Cells.

Authors:  Xiangtang Li; Hankun Hu; Shulin Zhao; Yi-Ming Liu
Journal:  Anal Chem       Date:  2016-05-04       Impact factor: 6.986

  3 in total