Literature DB >> 21835946

Lowering the dose in head CT using adaptive statistical iterative reconstruction.

K Kilic1, G Erbas, M Guryildirim, M Arac, E Ilgit, B Coskun.   

Abstract

BACKGROUND AND
PURPOSE: While CT has found wide use in medical practice, it is also a substantial source of radiation exposure and is associated with an increased lifetime risk of cancer. There is an urgent need for new approaches to reduce the radiation dose in CT. In this regard, ASIR is an alternative method to FBP. We assessed the effect of ASIR on dose reduction in adult head CT.
MATERIALS AND METHODS: We retrospectively evaluated a sample of 149 adult head CT examinations that were divided into 2 groups, STD and LD. We lowered the tube current and used ASIR in the LD group. SNR and CNR were analyzed. Dose parameters were recorded while subjective image noise, sharpness, diagnostic acceptability, and artifacts were graded. The Student t test, the Mann-Whitney U test, and κ statistics were used for statistical analyses.
RESULTS: We achieved a dose reduction of 31% in the LD group (STD, 2.3 ± 0.1 mSv; LD, 1.6 ± 0.1 mSv; P < .001). There was no significant difference in the noise measured in the air between the 2 comparison groups (P = .273). Noise in the CSF was higher in the STD group (P < .001), while the noise in the WM was higher in the LD group (P < .001). Differences in the CNR between groups were insignificant, but the STD group displayed better SNR values. There was no significant difference in the modal scores of diagnostic acceptability (P = .062) and the artifacts (P = .148) between the 2 groups. Better scores for subjective image noise (P < .001) and sharpness (P = .04) were observed in the STD group.
CONCLUSIONS: ASIR appears to be useful in reducing the dose in adult head CT examinations. While the effect of ASIR on noise reduction observed in the present study of head CT is less than that reported previously in abdomen and chest CT, these findings encourage further prospective studies in larger patient samples.

Entities:  

Mesh:

Year:  2011        PMID: 21835946      PMCID: PMC7965395          DOI: 10.3174/ajnr.A2585

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  24 in total

1.  A comparison of radiation doses between state-of-the-art multislice CT coronary angiography with iterative reconstruction, multislice CT coronary angiography with standard filtered back-projection and invasive diagnostic coronary angiography.

Authors:  O Gosling; R Loader; P Venables; C Roobottom; N Rowles; N Bellenger; G Morgan-Hughes
Journal:  Heart       Date:  2010-06       Impact factor: 5.994

2.  Comparison of image quality between conventional and low-dose nonenhanced head CT.

Authors:  Mark E Mullins; Michael H Lev; Peter Bove; Cara E O'Reilly; Sanjay Saini; James T Rhea; James H Thrall; George J Hunter; Leena M Hamberg; R Gilberto Gonzalez
Journal:  AJNR Am J Neuroradiol       Date:  2004-04       Impact factor: 3.825

3.  Impact of new technologies on dose reduction in CT.

Authors:  Ting-Yim Lee; Rethy K Chhem
Journal:  Eur J Radiol       Date:  2010-10       Impact factor: 3.528

4.  Diffuse lung disease: CT of the chest with adaptive statistical iterative reconstruction technique.

Authors:  Priyanka Prakash; Mannudeep K Kalra; Jeanne B Ackman; Subba R Digumarthy; Jiang Hsieh; Synho Do; Jo-Anne O Shepard; Matthew D Gilman
Journal:  Radiology       Date:  2010-07       Impact factor: 11.105

Review 5.  Innovations in CT dose reduction strategy: application of the adaptive statistical iterative reconstruction algorithm.

Authors:  Alvin C Silva; Holly J Lawder; Amy Hara; Jennifer Kujak; William Pavlicek
Journal:  AJR Am J Roentgenol       Date:  2010-01       Impact factor: 3.959

6.  Iterative reconstruction in image space (IRIS) in cardiac computed tomography: initial experience.

Authors:  Márcio Sommer Bittencourt; Bernhard Schmidt; Martin Seltmann; Gerd Muschiol; Dieter Ropers; Werner Günther Daniel; Stephan Achenbach
Journal:  Int J Cardiovasc Imaging       Date:  2010-12-01       Impact factor: 2.357

7.  Radiation dose reduction with chest computed tomography using adaptive statistical iterative reconstruction technique: initial experience.

Authors:  Priyanka Prakash; Mannudeep K Kalra; Subba R Digumarthy; Jiang Hsieh; Homer Pien; Sarabjeet Singh; Matthew D Gilman; Jo-Anne O Shepard
Journal:  J Comput Assist Tomogr       Date:  2010-01       Impact factor: 1.826

8.  Reducing the radiation dose for CT colonography using adaptive statistical iterative reconstruction: A pilot study.

Authors:  Kristina T Flicek; Amy K Hara; Alvin C Silva; Qing Wu; Mary B Peter; C Daniel Johnson
Journal:  AJR Am J Roentgenol       Date:  2010-07       Impact factor: 3.959

9.  Effect of tube voltage on image quality in 64-section multidetector 3D CT angiography: Evaluation with a vascular phantom with superimposed bone skull structures.

Authors:  Y Murakami; S Kakeda; K Kamada; N Ohnari; J Nishimura; M Ogawa; K Otsubo; Y Morishita; Y Korogi
Journal:  AJNR Am J Neuroradiol       Date:  2009-11-26       Impact factor: 3.825

10.  Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm--initial clinical experience.

Authors:  Daniele Marin; Rendon C Nelson; Sebastian T Schindera; Samuel Richard; Richard S Youngblood; Terry T Yoshizumi; Ehsan Samei
Journal:  Radiology       Date:  2010-01       Impact factor: 11.105

View more
  40 in total

1.  The use of adaptive statistical iterative reconstruction in pediatric head CT: a feasibility study.

Authors:  G A Vorona; G Zuccoli; T Sutcavage; B L Clayton; R C Ceschin; A Panigrahy
Journal:  AJNR Am J Neuroradiol       Date:  2012-05-24       Impact factor: 3.825

2.  Six iterative reconstruction algorithms in brain CT: a phantom study on image quality at different radiation dose levels.

Authors:  A Löve; M-L Olsson; R Siemund; F Stålhammar; I M Björkman-Burtscher; M Söderberg
Journal:  Br J Radiol       Date:  2013-09-18       Impact factor: 3.039

3.  Survey of volume CT dose index in Japan in 2014.

Authors:  Y Matsunaga; A Kawaguchi; K Kobayashi; Y Kinomura; M Kobayashi; Y Asada; K Minami; S Suzuki; K Chida
Journal:  Br J Radiol       Date:  2015-06-04       Impact factor: 3.039

4.  Full Dose-Reduction Potential of Statistical Iterative Reconstruction for Head CT Protocols in a Predominantly Pediatric Population.

Authors:  A E Mirro; S L Brady; R A Kaufman
Journal:  AJNR Am J Neuroradiol       Date:  2016-04-07       Impact factor: 3.825

5.  Radiation dose reduction in cerebral CT perfusion imaging using iterative reconstruction.

Authors:  Joris M Niesten; Irene C van der Schaaf; Alan J Riordan; Hugo W A M de Jong; Alexander D Horsch; Daniel Eijspaart; Ewoud J Smit; Willem P T M Mali; Birgitta K Velthuis
Journal:  Eur Radiol       Date:  2013-10-15       Impact factor: 5.315

6.  Diagnostic usefulness  of low-dose lumbar multi-detector CT with iterative reconstruction in trauma patients: acomparison with standard-dose CT.

Authors:  Sun Hwa Lee; Seong Jong Yun; Dong Hyeon Kim; Hyeon Hwan Jo; Jae Gwang Song; Yong Sung Park
Journal:  Br J Radiol       Date:  2017-07-14       Impact factor: 3.039

7.  Potential of combining iterative reconstruction with noise efficient detector design: aggressive dose reduction in head CT.

Authors:  H Brodoefel; B Bender; C Schabel; M Fenchel; U Ernemann; A Korn
Journal:  Br J Radiol       Date:  2015-04-01       Impact factor: 3.039

8.  Iterative reconstruction techniques for computed tomography part 2: initial results in dose reduction and image quality.

Authors:  Martin J Willemink; Tim Leiner; Pim A de Jong; Linda M de Heer; Rutger A J Nievelstein; Arnold M R Schilham; Ricardo P J Budde
Journal:  Eur Radiol       Date:  2013-01-16       Impact factor: 5.315

9.  Iterative reconstruction techniques for computed tomography Part 1: technical principles.

Authors:  Martin J Willemink; Pim A de Jong; Tim Leiner; Linda M de Heer; Rutger A J Nievelstein; Ricardo P J Budde; Arnold M R Schilham
Journal:  Eur Radiol       Date:  2013-01-12       Impact factor: 5.315

10.  Repeated head CT in the neurosurgical intensive care unit: feasibility of sinogram-affirmed iterative reconstruction-based ultra-low-dose CT for surveillance.

Authors:  I Corcuera-Solano; A H Doshi; A Noor; L N Tanenbaum
Journal:  AJNR Am J Neuroradiol       Date:  2014-02-20       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.