Literature DB >> 25827204

Potential of combining iterative reconstruction with noise efficient detector design: aggressive dose reduction in head CT.

H Brodoefel1, B Bender, C Schabel, M Fenchel, U Ernemann, A Korn.   

Abstract

OBJECTIVE: With further increase of CT numbers and their dominant contribution to medical exposure, there is a recent quest for more effective dose control. While reintroduction of iterative reconstruction (IR) has proved its potential in many applications, a novel focus is placed on more noise efficient detectors. Our purpose was to assess the potential of IR in combination with an integrated circuit detector (ICD) for aggressive dose reduction in head CT.
METHODS: Non-contrast low-dose head CT [190 mAs; weighted volume CT dose index (CTDIvol), 33.2 mGy] was performed in 50 consecutive patients, using a new noise efficient detector and IR. Images were assessed in terms of quantitative and qualitative image quality and compared with standard dose acquisitions (320 mAs; CTDIvol, 59.7 mGy) using a conventional detector and filtered back projection.
RESULTS: By combining ICD and IR in low-dose examinations, the signal to noise was improved by about 13% above the baseline level in the standard-dose control group. Both, contrast-to-noise ratio (2.02 ± 0.6 vs 1.88 ± 0.4; p = 0.18) and objective measurements of image sharpness (695 ± 84 vs 705 ± 151 change in Hounsfield units per pixel; p = 0.79) were fully preserved in the low-dose group. Likewise, there was no significant difference in the grading of several subjective image quality parameters when both noise-reducing strategies were used in low-dose examinations.
CONCLUSION: Combination of noise efficient detector with IR allows for meaningful dose reduction in head CT without compromise of standard image quality. ADVANCES IN KNOWLEDGE: Our study demonstrates the feasibility of almost 50% dose reduction in head CT dose (1.1 mSv per scan) through combination of novel dose-reducing strategies.

Entities:  

Mesh:

Year:  2015        PMID: 25827204      PMCID: PMC4628441          DOI: 10.1259/bjr.20140404

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  27 in total

1.  Managing patient dose in computed tomography. A report of the International Commission on Radiological Protection.

Authors: 
Journal:  Ann ICRP       Date:  2000

2.  Reducing image noise in computed tomography (CT) colonography: effect of an integrated circuit CT detector.

Authors:  Yu Liu; Shuai Leng; Gregory J Michalak; Thomas J Vrieze; Xinhui Duan; Mingliang Qu; Maria M Shiung; Cynthia H McCollough; Joel G Fletcher
Journal:  J Comput Assist Tomogr       Date:  2014 May-Jun       Impact factor: 1.826

3.  How far can the radiation dose be lowered in head CT with iterative reconstruction? Analysis of imaging quality and diagnostic accuracy.

Authors:  Tung-Hsin Wu; Sheng-Che Hung; Jing-Yi Sun; Chung-Jung Lin; Chung-Hsien Lin; Chen Fen Chiu; Min-Jsuan Liu; Michael Mu Huo Teng; Wan-Yuo Guo; Cheng-Yen Chang
Journal:  Eur Radiol       Date:  2013-05-04       Impact factor: 5.315

4.  Added value of integrated circuit detector in head CT: objective and subjective image quality in comparison to conventional detector design.

Authors:  Andreas Korn; Benjamin Bender; Daniel Spira; Christoph Schabel; Rafeeque Bhadelia; Claus Claussen; Ulrike Ernemann; Harald Brodoefel
Journal:  Acad Radiol       Date:  2014-09-08       Impact factor: 3.173

5.  Integrated circuit detector technology in abdominal CT: added value in obese patients.

Authors:  Fabian Morsbach; Sebastian Bickelhaupt; Susan Rätzer; Bernhard Schmidt; Hatem Alkadhi
Journal:  AJR Am J Roentgenol       Date:  2014-02       Impact factor: 3.959

6.  Electronic noise in CT detectors: Impact on image noise and artifacts.

Authors:  Xinhui Duan; Jia Wang; Shuai Leng; Bernhard Schmidt; Thomas Allmendinger; Katharine Grant; Thomas Flohr; Cynthia H McCollough
Journal:  AJR Am J Roentgenol       Date:  2013-10       Impact factor: 3.959

7.  Adaptive statistical iterative reconstruction reduces patient radiation dose in neuroradiology CT studies.

Authors:  Peter Komlosi; Yanrong Zhang; Carlos Leiva-Salinas; David Ornan; James T Patrie; Wenjun Xin; Deborah Grady; Max Wintermark
Journal:  Neuroradiology       Date:  2014-01-03       Impact factor: 2.804

8.  Iterative reconstruction to preserve image quality and diagnostic accuracy at reduced radiation dose in coronary CT angiography: an intraindividual comparison.

Authors:  Wei-Hua Yin; Bin Lu; Nan Li; Lei Han; Zhi-Hui Hou; Run-Ze Wu; Yong-Jian Wu; Hong-Xia Niu; Shi-Liang Jiang; Aleksander W Krazinski; Ullrich Ebersberger; Felix G Meinel; U Joseph Schoepf
Journal:  JACC Cardiovasc Imaging       Date:  2013-10-23

9.  Effect of low doses of ionising radiation in infancy on cognitive function in adulthood: Swedish population based cohort study.

Authors:  Per Hall; Hans-Olov Adami; Dimitrios Trichopoulos; Nancy L Pedersen; Pagona Lagiou; Anders Ekbom; Martin Ingvar; Marie Lundell; Fredrik Granath
Journal:  BMJ       Date:  2004-01-03

10.  Stenosis quantification in coronary CT angiography: impact of an integrated circuit detector with iterative reconstruction.

Authors:  Fabian Morsbach; Lotus Desbiolles; André Plass; Sebastian Leschka; Bernhard Schmidt; Volkmar Falk; Hatem Alkadhi; Paul Stolzmann
Journal:  Invest Radiol       Date:  2013-01       Impact factor: 6.016

View more
  3 in total

Review 1.  Unintended Consequences of Sensor, Signal, and Imaging Informatics: New Problems and New Solutions.

Authors:  C Hughes; S Voros; A Moreau-Gaudry
Journal:  Yearb Med Inform       Date:  2016-11-10

2.  Dose Reduction While Preserving Diagnostic Quality in Head CT: Advancing the Application of Iterative Reconstruction Using a Live Animal Model.

Authors:  F D Raslau; E J Escott; J Smiley; C Adams; D Feigal; H Ganesh; C Wang; J Zhang
Journal:  AJNR Am J Neuroradiol       Date:  2019-10-10       Impact factor: 3.825

3.  Helical CT with variable target noise levels for dose reduction in chest, abdomen and pelvis CT.

Authors:  Patrik Rogalla; Madhusudan Paravasthu; Christin Farrell; Sonja Kandel
Journal:  Eur Radiol       Date:  2018-03-21       Impact factor: 5.315

  3 in total