Literature DB >> 20538667

A comparison of radiation doses between state-of-the-art multislice CT coronary angiography with iterative reconstruction, multislice CT coronary angiography with standard filtered back-projection and invasive diagnostic coronary angiography.

O Gosling1, R Loader, P Venables, C Roobottom, N Rowles, N Bellenger, G Morgan-Hughes.   

Abstract

OBJECTIVE: To accurately compare the radiation dose between prospectively gated cardiac multidetector CT (with and without iterative reconstruction) and diagnostic invasive coronary angiography using the latest International Commission on Radiological Protection 103 (ICRP) tissue weightings. DESIGN, SETTING AND PATIENTS: A retrospective analysis of consecutive patients presenting to a university teaching hospital for investigation of coronary artery disease. Radiation doses for each technique were calculated using computational Monte Carlo modelling of a standard Cristy phantom rather than the application of previously published conversion factors. While these have frequently been used in other studies, they are based on out-dated ICRP tissue weightings (ICRP 60) and are for the whole chest rather than for structures irradiated in cardiac imaging. In order to allow a comparison, doses were calculated and expressed in terms of effective dose in millisieverts (mSv).
RESULTS: From a population presenting for angiography within a clinical service, the median radiation dose from cardiac CT with standard filtered back-projection (84 patients, 5.4 mSv) was comparable with the dose from invasive diagnostic coronary angiography (94 patients, 6.3 mSv). The dose for cardiac CT using iterative reconstruction was significantly lower (39 patients, 2.5 mSv).
CONCLUSION: The median effective dose from cardiac CT with standard filtered back-projection was comparable with the effective dose from invasive coronary angiography, even with application of the most contemporary ICRP tissue weightings and use of cardiac specific volumes. Cardiac CT scanning incorporating iterative reconstruction resulted in a significant reduction in the effective dose.

Entities:  

Mesh:

Year:  2010        PMID: 20538667     DOI: 10.1136/hrt.2010.195909

Source DB:  PubMed          Journal:  Heart        ISSN: 1355-6037            Impact factor:   5.994


  38 in total

1.  Non-invasive assessment of functionally relevant coronary artery stenoses with quantitative CT perfusion: preliminary clinical experiences.

Authors:  Aaron So; Gerald Wisenberg; Ali Islam; Justin Amann; Walter Romano; James Brown; Dennis Humen; George Jablonsky; Jian-Ying Li; Jiang Hsieh; Ting-Yim Lee
Journal:  Eur Radiol       Date:  2011-09-21       Impact factor: 5.315

2.  Iterative reconstruction in head CT: image quality of routine and low-dose protocols in comparison with standard filtered back-projection.

Authors:  A Korn; M Fenchel; B Bender; S Danz; T K Hauser; D Ketelsen; T Flohr; C D Claussen; M Heuschmid; U Ernemann; H Brodoefel
Journal:  AJNR Am J Neuroradiol       Date:  2011-10-27       Impact factor: 3.825

3.  The effect of adaptive iterative dose reduction on image quality in 320-detector row CT coronary angiography.

Authors:  F Tatsugami; M Matsuki; G Nakai; Y Inada; S Kanazawa; Y Takeda; H Morita; H Takada; S Yoshikawa; K Fukumura; Y Narumi
Journal:  Br J Radiol       Date:  2012-01-17       Impact factor: 3.039

4.  The use of adaptive statistical iterative reconstruction in pediatric head CT: a feasibility study.

Authors:  G A Vorona; G Zuccoli; T Sutcavage; B L Clayton; R C Ceschin; A Panigrahy
Journal:  AJNR Am J Neuroradiol       Date:  2012-05-24       Impact factor: 3.825

5.  CT evaluation of coronary artery stents with iterative image reconstruction: improvements in image quality and potential for radiation dose reduction.

Authors:  Ullrich Ebersberger; Francesco Tricarico; U Joseph Schoepf; Philipp Blanke; J Reid Spears; Garrett W Rowe; William T Halligan; Thomas Henzler; Fabian Bamberg; Alexander W Leber; Ellen Hoffmann; Paul Apfaltrer
Journal:  Eur Radiol       Date:  2012-07-10       Impact factor: 5.315

6.  Effect of bismuth breast shielding on radiation dose and image quality in coronary CT angiography.

Authors:  Andrew J Einstein; Carl D Elliston; Daniel W Groves; Bin Cheng; Steven D Wolff; Gregory D N Pearson; M Robert Peters; Lynne L Johnson; Sabahat Bokhari; Gary W Johnson; Ketan Bhatia; Theodore Pozniakoff; David J Brenner
Journal:  J Nucl Cardiol       Date:  2011-11-09       Impact factor: 5.952

Review 7.  Current state of hybrid imaging: attenuation correction and fusion.

Authors:  Jonathon A Nye; Tracy L Faber
Journal:  J Nucl Cardiol       Date:  2011-05-07       Impact factor: 5.952

8.  Lowering the dose in head CT using adaptive statistical iterative reconstruction.

Authors:  K Kilic; G Erbas; M Guryildirim; M Arac; E Ilgit; B Coskun
Journal:  AJNR Am J Neuroradiol       Date:  2011-08-11       Impact factor: 3.825

9.  Repeated head CT in the neurosurgical intensive care unit: feasibility of sinogram-affirmed iterative reconstruction-based ultra-low-dose CT for surveillance.

Authors:  I Corcuera-Solano; A H Doshi; A Noor; L N Tanenbaum
Journal:  AJNR Am J Neuroradiol       Date:  2014-02-20       Impact factor: 3.825

10.  Beyond Coronary Stenosis: Coronary Computed Tomographic Angiography for the Assessment of Atherosclerotic Plaque Burden.

Authors:  Alan C Kwan; George Cater; Jose Vargas; David A Bluemke
Journal:  Curr Cardiovasc Imaging Rep       Date:  2013-01-22
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.