Literature DB >> 10701515

Correlation between CT numbers and tissue parameters needed for Monte Carlo simulations of clinical dose distributions.

W Schneider1, T Bortfeld, W Schlegel.   

Abstract

We describe a new method to convert CT numbers into mass density and elemental weights of tissues required as input for dose calculations with Monte Carlo codes such as EGS4. As a first step, we calculate the CT numbers for 71 human tissues. To reduce the effort for the necessary fits of the CT numbers to mass density and elemental weights, we establish four sections on the CT number scale, each confined by selected tissues. Within each section, the mass density and elemental weights of the selected tissues are interpolated. For this purpose, functional relationships between the CT number and each of the tissue parameters, valid for media which are composed of only two components in varying proportions, are derived. Compared with conventional data fits, no loss of accuracy is accepted when using the interpolation functions. Assuming plausible values for the deviations of calculated and measured CT numbers, the mass density can be determined with an accuracy better than 0.04 g cm(-3). The weights of phosphorus and calcium can be determined with maximum uncertainties of 1 or 2.3 percentage points (pp) respectively. Similar values can be achieved for hydrogen (0.8 pp) and nitrogen (3 pp). For carbon and oxygen weights, errors up to 14 pp can occur. The influence of the elemental weights on the results of Monte Carlo dose calculations is investigated and discussed.

Entities:  

Mesh:

Year:  2000        PMID: 10701515     DOI: 10.1088/0031-9155/45/2/314

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  119 in total

1.  Design and development of a new micro-beam treatment planning system: effectiveness of algorithms of optimization and dose calculations and potential of micro-beam treatment.

Authors:  Hidenobu Tachibana; Hiroyuki Kojima; Noritaka Yusa; Satoshi Miyajima; Akihisa Tsuda; Takashi Yamashita
Journal:  Radiol Phys Technol       Date:  2012-04-29

2.  A parameter study of pencil beam proton dose distributions for the treatment of ocular melanoma utilizing spot scanning.

Authors:  Kenneth Sutherland; Satoshi Miyajima; Hiroyuki Date; Hiroki Shirato; Masayori Ishikawa; Masao Murakami; Mitsuru Yamagiwa; Paul Bolton; Toshiki Tajima
Journal:  Radiol Phys Technol       Date:  2009-09-19

3.  Bone acquisition in healthy young females is reciprocally related to marrow adiposity.

Authors:  Natascia Di Iorgi; Ashley O Mo; Kate Grimm; Tishya A L Wren; Frederick Dorey; Vicente Gilsanz
Journal:  J Clin Endocrinol Metab       Date:  2010-04-14       Impact factor: 5.958

4.  A new technique to characterize CT scanner bow-tie filter attenuation and applications in human cadaver dosimetry simulations.

Authors:  Xinhua Li; Jim Q Shi; Da Zhang; Sarabjeet Singh; Atul Padole; Alexi Otrakji; Mannudeep K Kalra; X George Xu; Bob Liu
Journal:  Med Phys       Date:  2015-11       Impact factor: 4.071

5.  Four-dimensional radiotherapeutic dose calculation using biomechanical respiratory motion description.

Authors:  Petru Manescu; Hamid Ladjal; Joseph Azencot; Michael Beuve; Etienne Testa; Behzad Shariat
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-09-01       Impact factor: 2.924

6.  Murine vs human tissue compositions: implications of using human tissue compositions for photon energy absorption in mice.

Authors:  Lotte Ejr Schyns; Daniëlle Bp Eekers; Brent van der Heyden; Isabel P Almeida; Ana Vaniqui; Frank Verhaegen
Journal:  Br J Radiol       Date:  2018-11-30       Impact factor: 3.039

7.  A full-scale clinical prototype for proton range verification using prompt gamma-ray spectroscopy.

Authors:  Fernando Hueso-González; Moritz Rabe; Thomas A Ruggieri; Thomas Bortfeld; Joost M Verburg
Journal:  Phys Med Biol       Date:  2018-09-17       Impact factor: 3.609

8.  Feasibility of proton-activated implantable markers for proton range verification using PET.

Authors:  Jongmin Cho; Geoffrey Ibbott; Michael Gillin; Carlos Gonzalez-Lepera; Uwe Titt; Harald Paganetti; Matthew Kerr; Osama Mawlawi
Journal:  Phys Med Biol       Date:  2013-10-08       Impact factor: 3.609

9.  Reciprocal relation between marrow adiposity and the amount of bone in the axial and appendicular skeleton of young adults.

Authors:  Natascia Di Iorgi; Michael Rosol; Steven D Mittelman; Vicente Gilsanz
Journal:  J Clin Endocrinol Metab       Date:  2008-04-01       Impact factor: 5.958

10.  Feasibility of Using Distal Endpoints for In-room PET Range Verification of Proton Therapy.

Authors:  Kira Grogg; Xuping Zhu; Chul Hee Min; Brian Winey; Thomas Bortfeld; Harald Paganetti; Helen A Shih; Georges El Fakhri
Journal:  IEEE Trans Nucl Sci       Date:  2013-10       Impact factor: 1.679

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.