Literature DB >> 25860401

Construction of mouse phantoms from segmented CT scan data for radiation dosimetry studies.

D Welch1, A D Harken, G Randers-Pehrson, D J Brenner.   

Abstract

We present the complete construction methodology for an anatomically accurate mouse phantom made using materials which mimic the characteristics of tissue, lung, and bone for radiation dosimetry studies. Phantoms were constructed using 2 mm thick slices of tissue equivalent material which was precision machined to clear regions for insertion of lung and bone equivalent material where appropriate. Images obtained using a 3D computed tomography (CT) scan clearly indicate regions of tissue, lung, and bone that match their position within the original mouse CT scan. Additionally, radiographic films are used with the phantom to demonstrate dose mapping capabilities. The construction methodology presented here can be quickly and easily adapted to create a phantom of any specific small animal given a segmented CT scan of the animal. These physical phantoms are a useful tool to examine individual organ dose and dosimetry within mouse systems that are complicated by density inhomogeneity due to bone and lung regions.

Entities:  

Mesh:

Year:  2015        PMID: 25860401      PMCID: PMC4412154          DOI: 10.1088/0031-9155/60/9/3589

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  26 in total

1.  Comparison of measured and calculated radiotherapy doses in the chest region of an inhomogeneous humanoid phantom.

Authors:  L McDermott; A Perkins
Journal:  Australas Phys Eng Sci Med       Date:  2004-03       Impact factor: 1.430

2.  Influence of voxel size on specific absorbed fractions and S-values in a mouse voxel phantom.

Authors:  A Mohammadi; S Kinase
Journal:  Radiat Prot Dosimetry       Date:  2010-11-30       Impact factor: 0.972

3.  Dosimetric variation due to the photon beam energy in the small-animal irradiation: a Monte Carlo study.

Authors:  James C L Chow; Michael K K Leung; Patricia E Lindsay; David A Jaffray
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

4.  Radiation dose from single-heartbeat coronary CT angiography performed with a 320-detector row volume scanner.

Authors:  Andrew J Einstein; Carl D Elliston; Andrew E Arai; Marcus Y Chen; Richard Mather; Gregory D N Pearson; Robert L Delapaz; Edward Nickoloff; Ajoy Dutta; David J Brenner
Journal:  Radiology       Date:  2010-03       Impact factor: 11.105

5.  Empirical dual energy calibration (EDEC) for cone-beam computed tomography.

Authors:  Philip Stenner; Timo Berkus; Marc Kachelriess
Journal:  Med Phys       Date:  2007-09       Impact factor: 4.071

6.  Dosimetry intercomparisons for evaluation of late effects of ionizing radiation.

Authors:  J J Broerse; J Zoetelief; K J Puite
Journal:  Acta Radiol Oncol Radiat Phys Biol       Date:  1978

7.  Performance evaluation of the microPET R4 PET scanner for rodents.

Authors:  Christof Knoess; Stefan Siegel; Anne Smith; Danny Newport; Norbert Richerzhagen; Alexandra Winkeler; Andreas Jacobs; Rhonda N Goble; Rudolf Graf; Klaus Wienhard; Wolf-Dieter Heiss
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-01-21       Impact factor: 9.236

8.  Tissue-equivalent materials for construction of tomographic dosimetry phantoms in pediatric radiology.

Authors:  A K Jones; D E Hintenlang; W E Bolch
Journal:  Med Phys       Date:  2003-08       Impact factor: 4.071

9.  Monte Carlo simulations of absorbed dose in a mouse phantom from 18-fluorine compounds.

Authors:  Richard Taschereau; Arion F Chatziioannou
Journal:  Med Phys       Date:  2007-03       Impact factor: 4.071

10.  Construction of anthropomorphic phantoms for use in dosimetry studies.

Authors:  James F Winslow; Daniel E Hyer; Ryan F Fisher; Christopher J Tien; David E Hintenlang
Journal:  J Appl Clin Med Phys       Date:  2009-08-06       Impact factor: 2.102

View more
  8 in total

1.  Scattered Dose Calculations and Measurements in a Life-Like Mouse Phantom.

Authors:  David Welch; Leah Turner; Michael Speiser; Gerhard Randers-Pehrson; David J Brenner
Journal:  Radiat Res       Date:  2017-01-31       Impact factor: 2.841

2.  Novel technique for high-precision stereotactic irradiation of mouse brains.

Authors:  J Hartmann; J Wölfelschneider; C Stache; R Buslei; A Derer; M Schwarz; T Bäuerle; R Fietkau; U S Gaipl; C Bert; A Hölsken; B Frey
Journal:  Strahlenther Onkol       Date:  2016-07-11       Impact factor: 3.621

3.  Quality Assessment of Stereotactic Radiosurgery of a Melanoma Brain Metastases Model Using a Mouselike Phantom and the Small Animal Radiation Research Platform.

Authors:  Cheng-Chia Wu; Kunal R Chaudhary; Yong Hum Na; David Welch; Paul J Black; Adam M Sonabend; Peter Canoll; Yvonne M Saenger; Tony J C Wang; Cheng-Shie Wuu; Tom K Hei; Simon K Cheng
Journal:  Int J Radiat Oncol Biol Phys       Date:  2017-05-19       Impact factor: 7.038

4.  Study logistics that can impact medical countermeasure efficacy testing in mouse models of radiation injury.

Authors:  Andrea L DiCarlo; Zulmarie Perez Horta; Carmen I Rios; Merriline M Satyamitra; Lanyn P Taliaferro; David R Cassatt
Journal:  Int J Radiat Biol       Date:  2020-09-24       Impact factor: 2.694

5.  Development of a minipig physical phantom from CT data.

Authors:  Sooyeun Park; Pilsoo Lee; Wi-Ho Ha; Han Sung Kim; Byeong Ryong Park; Jae Seok Kim; Sehwan Shim; Sunhoo Park; Young-Su Kim; Chan Hyeong Kim; Young-Woo Jin
Journal:  J Radiat Res       Date:  2017-09-01       Impact factor: 2.724

Review 6.  Dosimetry in Micro-computed Tomography: a Review of the Measurement Methods, Impacts, and Characterization of the Quantum GX Imaging System.

Authors:  Jeffrey A Meganck; Bob Liu
Journal:  Mol Imaging Biol       Date:  2017-08       Impact factor: 3.488

Review 7.  Recent advances on the development of phantoms using 3D printing for imaging with CT, MRI, PET, SPECT, and ultrasound.

Authors:  Valeria Filippou; Charalampos Tsoumpas
Journal:  Med Phys       Date:  2018-06-22       Impact factor: 4.071

8.  Deep learning-enabled multi-organ segmentation in whole-body mouse scans.

Authors:  Oliver Schoppe; Chenchen Pan; Javier Coronel; Hongcheng Mai; Zhouyi Rong; Mihail Ivilinov Todorov; Annemarie Müskes; Fernando Navarro; Hongwei Li; Ali Ertürk; Bjoern H Menze
Journal:  Nat Commun       Date:  2020-11-06       Impact factor: 14.919

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.