Literature DB >> 21812574

Effects of washer on the stress distribution of mini-implant.

Hyoung-Jun Jang1, Soon-Yong Kwon, Seong-Hun Kim, Young-Guk Park, Su-Jung Kim.   

Abstract

OBJECTIVE: To investigate the biomechanical effects of 'washer' designed for improving mini-implant stability.
MATERIALS AND METHODS: Four three-dimensional finite element models of the mini-implant and surrounding bone were constructed with washers in different spike lengths (1.5 mm, 2.0 mm, and 2.5 mm). The force was applied in two directions (45° and 90°). The stress distribution on surrounding bone and the displacement of the mini-implant were analyzed. Plots of tensile stress, compression stress, and displacement were calculated, and maximum values in each category were analyzed.
RESULTS: The stress distribution was different between the models with washer and without washer. However, no remarkable differences in stress distribution were observed among the models with washer, regardless of spike length. A significantly greater displacement value was observed in the model without washer compared to the models with washer, but no notable difference in displacement value was found among the models with washer. The plots of the displacement distribution of the models with washer presented notable pattern differences as compared with that of the model without washer.
CONCLUSION: With the use of the washer, a more homogeneous distribution of bone stress and less displacement of the mini-implant can be achieved.

Entities:  

Mesh:

Year:  2011        PMID: 21812574      PMCID: PMC8881023          DOI: 10.2319/021411-107.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  15 in total

1.  Do miniscrews remain stationary under orthodontic forces?

Authors:  Eric J W Liou; Betty C J Pai; James C Y Lin
Journal:  Am J Orthod Dentofacial Orthop       Date:  2004-07       Impact factor: 2.650

2.  Biomechanical effect of abutment on stability of orthodontic mini-implant. A finite element analysis.

Authors:  Mitsuru Motoyoshi; Shinya Yano; Takashi Tsuruoka; Noriyoshi Shimizu
Journal:  Clin Oral Implants Res       Date:  2005-08       Impact factor: 5.977

3.  Numerical analysis of bone adaptation around an oral implant due to overload stress.

Authors:  V Crupi; E Guglielmino; G La Rosa; J Vander Sloten; H Van Oosterwyck
Journal:  Proc Inst Mech Eng H       Date:  2004       Impact factor: 1.617

4.  Pitch and longitudinal fluting effects on the primary stability of miniscrew implants.

Authors:  Christine L Brinley; Rolf Behrents; Ki Beom Kim; Sridhar Condoor; Hee-Moon Kyung; Peter H Buschang
Journal:  Angle Orthod       Date:  2009-11       Impact factor: 2.079

5.  Evaluating parameters of osseointegrated dental implants using finite element analysis--a two-dimensional comparative study examining the effects of implant diameter, implant shape, and load direction.

Authors:  E P Holmgren; R J Seckinger; L M Kilgren; F Mante
Journal:  J Oral Implantol       Date:  1998       Impact factor: 1.779

6.  Trabecular bone mineral density of mandible and alveolar height in postmenopausal women.

Authors:  E Klemetti; P Vainio; V Lassila; E Alhava
Journal:  Scand J Dent Res       Date:  1993-06

7.  Local stresses and bone adaption around orthopedic implants.

Authors:  R Huiskes; D Nunamaker
Journal:  Calcif Tissue Int       Date:  1984       Impact factor: 4.333

8.  Basic study of the measurement of bone mineral content of cortical and cancellous bone of the mandible by computed tomography.

Authors:  Y Iwashita
Journal:  Dentomaxillofac Radiol       Date:  2000-07       Impact factor: 2.419

9.  Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage.

Authors:  Shouichi Miyawaki; Isao Koyama; Masahide Inoue; Katsuaki Mishima; Toshio Sugahara; Teruko Takano-Yamamoto
Journal:  Am J Orthod Dentofacial Orthop       Date:  2003-10       Impact factor: 2.650

10.  Comparison of stability between cylindrical and conical type mini-implants. Mechanical and histological properties.

Authors:  Jong-Wan Kim; Seung-Hak Baek; Tae-Woo Kim; Young-Il Chang
Journal:  Angle Orthod       Date:  2008-07       Impact factor: 2.079

View more
  3 in total

1.  Evaluation of miniscrew stability using an automatic embedding auxiliary skeletal anchorage device.

Authors:  Yasuhiko Oga; Hiroshi Tomonari; Sangho Kwon; Takaharu Kuninori; Takakazu Yagi; Shouichi Miyawaki
Journal:  Angle Orthod       Date:  2018-09-01       Impact factor: 2.079

Review 2.  Systematic review of mini-implant displacement under orthodontic loading.

Authors:  Manuel Nienkemper; Jörg Handschel; Dieter Drescher
Journal:  Int J Oral Sci       Date:  2013-12-20       Impact factor: 6.344

3.  Evaluation of stress generation on the cortical bone and the palatal micro-implant complex during the implant-supported en masse retraction in lingual orthodontic technique using the FEM: Original research.

Authors:  Tarulatha Revanappa Shyagali; Dhaval Aghera
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2019-10-07
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.