Literature DB >> 15224057

Do miniscrews remain stationary under orthodontic forces?

Eric J W Liou1, Betty C J Pai, James C Y Lin.   

Abstract

Miniscrews have been used in recent years for anchorage in orthodontic treatment. However, it is not clear whether the miniscrews are absolutely stationary or move when force is applied. Sixteen adult patients with miniscrews (diameter = 2 mm, length = 17 mm) as the maxillary anchorage were included in this study. Miniscrews were inserted on the maxillary zygomatic buttress as a direct anchorage for en masse anterior retraction. Nickel-titanium closed-coil springs were placed for the retraction 2 weeks after insertion of the miniscrews. Cephalometric radiographs were taken immediately before force application (T1) and 9 months later (T2). The cephalometric tracings at T1 and T2 were superimposed for the overall best fit on the structures of the maxilla, cranial base, and cranial vault to determine any movement of the miniscrews. The miniscrews were also evaluated clinically for their mobility (0: no movement, 1: < or =0.5 mm, 2: 0.5-1.0 mm, 3: >1.0 mm). The mobility of all miniscrews was 0 at T1 and T2. On average, the miniscrews tipped forward significantly, by 0.4 mm at the screw head. The miniscrews were extruded and tipped forward (-1.0 to 1.5 mm) in 7 of the 16 patients. Miniscrews are a stable anchorage but do not remain absolutely stationary throughout orthodontic loading. They might move according to the orthodontic loading in some patients. To prevent miniscrews hitting any vital organs because of displacement, it is recommended that they be placed in a non-tooth-bearing area that has no foramen, major nerves, or blood vessel pathways, or in a tooth-bearing area allowing 2 mm of safety clearance between the miniscrew and dental root.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15224057     DOI: 10.1016/j.ajodo.2003.06.018

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  67 in total

1.  Morphological and structural characteristics of orthodontic mini-implants.

Authors:  Saeed AlSamak; Elias Bitsanis; Margarita Makou; George Eliades
Journal:  J Orofac Orthop       Date:  2012-01-12       Impact factor: 1.938

2.  Case studies on local orthodontic traction by minis-implants before implant rehabilitation.

Authors:  Pei Shen; Wei-Feng Xu; Zhi-Gui Ma; Shan-Yong Zhang; Ying Zhang
Journal:  Int J Clin Exp Med       Date:  2015-05-15

3.  Craniofacial growth patterns in patients with congenitally missing permanent teeth.

Authors:  Natascha Bauer; Katinka Heckmann; Andrea Sand; Jörg A Lisson
Journal:  J Orofac Orthop       Date:  2009-03-26       Impact factor: 1.938

4.  Primary migration of a mini-implant under a functional orthodontic loading.

Authors:  Joseph W Pittman; Anand Navalgund; Steve H Byun; Hechang Huang; Albert H Kim; Do-Gyoon Kim
Journal:  Clin Oral Investig       Date:  2013-07-17       Impact factor: 3.573

5.  Microanchor mediated upper molar intrusion in deep posterior bite after long-term edentulousness for prosthetic reconstruction with dental implants.

Authors:  Constantin A Landes; Bettina Glasl; Stefan Kopp; Robert Sader; Björn Ludwig
Journal:  Oral Maxillofac Surg       Date:  2008-09

6.  Mass retraction movement of the anterior upper teeth using orthodontic mini-implants as anchorage.

Authors:  Leonardo Henrique de Lima Araújo; Elton Gonçalves Zenóbio; Wellington Pacheco; Maurício Greco Cosso; Flávio Ricardo Manzi; Jamil Awad Shibli
Journal:  Oral Maxillofac Surg       Date:  2011-01-28

7.  En-masse Retraction of the Maxillary Anterior Teeth by Applying Force from Four Different Levels - A Finite Element Study.

Authors:  Chetan S; Kanhoba M Keluskar; Vikram N Vasisht; Siddharth Revankar
Journal:  J Clin Diagn Res       Date:  2014-09-20

8.  Effect of piezocision on mandibular second molar protraction.

Authors:  Marwan M Al-Areqi; Elham S Abu Alhaija; Emad F Al-Maaitah
Journal:  Angle Orthod       Date:  2020-05-01       Impact factor: 2.079

9.  Failure rates for stainless steel versus titanium alloy infrazygomatic crest bone screws: A single-center, randomized double-blind clinical trial.

Authors:  Chris H Chang; Joshua S Lin; W Eugene Roberts
Journal:  Angle Orthod       Date:  2018-10-29       Impact factor: 2.079

10.  Effects of micro-osteoperforations on intraoral miniscrew anchored maxillary molar distalization : A randomized clinical trial.

Authors:  Kemal Gulduren; Hayriye Tumer; Ulas Oz
Journal:  J Orofac Orthop       Date:  2020-01-13       Impact factor: 1.938

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.