Local stresses and bone adaption around orthopedic implants.

R Huiskes, D Nunamaker.   

Abstract

The severest long-term complications of orthopedic joint-prostheses are associated with loosening of the implant-bone interface, due to adverse reactions in bone and subsequent weakening of the connection between the two materials. Mechanical stresses, caused by joint loading, play a key role in the adaption of interface bone and in the loosening process. In the present study, it is shown how local interface stress patterns can be evaluated using advanced methods of computer-based, engineering stress analyses (the Finite Element Method, FEM). The stress patterns are compared with the local bone structure and bone resorption phenomena as found in animal experiments. The results indicate that loosening and bone resorption is associated with high peak stresses at the interface in the immediate post-operative stage. In addition, there appears to be similarity between the local stress patterns and the bone morphology at the interface if resorption does not occur. Finally, it is found that implants of high local stiffness generate lower peak stresses in bone, as compared with low stiffness implants.

Mesh:

Substances:

Year:  1984        PMID: 6430510     DOI: 10.1007/bf02406143

Source DB:  PubMed          Journal:  Calcif Tissue Int        ISSN: 0171-967X            Impact factor:   4.333


  13 in total

1.  Side-effects of acrylic cement implanted into bone. A histologicl, (micro)angiographic, fluorescence-microscopic and autoradiog-aphic study in the rabbit femur.

Authors:  R Feith
Journal:  Acta Orthop Scand Suppl       Date:  1975

2.  [The reaction of bone to bone-cement in the replacement of the hip joint].

Authors:  H G Willert; P Puls
Journal:  Arch Orthop Unfallchir       Date:  1972

3.  Total hip-joint replacement in the United States.

Authors: 
Journal:  JAMA       Date:  1982-10-15       Impact factor: 56.272

4.  A new approach to the fixation of a metacarpophalangeal joint prosthesis.

Authors:  P S Walker; D Nunamaker; R Huiskes; T Parchinski; D Greene
Journal:  Eng Med       Date:  1983-07

5.  Ten-year follow-up study of total hip replacement.

Authors:  R N Stauffer
Journal:  J Bone Joint Surg Am       Date:  1982-09       Impact factor: 5.284

6.  Observations upon the interface between bone and polymethylmethacrylate cement.

Authors:  M A Freeman; G W Bradley; P A Revell
Journal:  J Bone Joint Surg Br       Date:  1982

7.  Changes in the bone-cement interface after total hip replacement. An in vivo animal study.

Authors:  E L Radin; C T Rubin; E L Thrasher; L E Lanyon; A M Crugnola; A S Schiller; I L Paul; R M Rose
Journal:  J Bone Joint Surg Am       Date:  1982-10       Impact factor: 5.284

8.  Influence of a functional dynamic loading on bone ingrowth into surface pores of orthopedic implants.

Authors:  P Ducheyne; P De Meester; E Aernoudt
Journal:  J Biomed Mater Res       Date:  1977-11

9.  Biologic fixation and bone modeling with an unconstrained canine total knee prosthesis.

Authors:  J D Bobyn; H U Cameron; D Abdulla; R M Pilliar; G C Weatherly
Journal:  Clin Orthop Relat Res       Date:  1982-06       Impact factor: 4.176

10.  Experimental reaming of the proximal femur and acrylic cement implantation: vascular and histologic effects.

Authors:  F W Rhinelander; C L Nelson; R D Stewart; C L Stewart
Journal:  Clin Orthop Relat Res       Date:  1979-06       Impact factor: 4.176

View more
  11 in total

1.  Clinical results and radiologic findings after cementless implantation of PCA stems in total hip replacement.

Authors:  V Jansson; H J Refior
Journal:  Arch Orthop Trauma Surg       Date:  1992       Impact factor: 3.067

2.  High pressure may inhibit periprosthetic osteogenesis.

Authors:  Kongzu Hu; Chengtao Wang; Xianlong Zhang
Journal:  J Bone Miner Metab       Date:  2009-11-17       Impact factor: 2.626

3.  Accuracy of torque-limiting devices used for mini-implant placement--an in vitro study.

Authors:  Alexander Pauls; Manuel Nienkemper; Dieter Drescher
Journal:  J Orofac Orthop       Date:  2013-03-08       Impact factor: 1.938

4.  3D finite element non linear analysis on the stress state at bone-implant interface in dental osteointegrated implants.

Authors:  G Sannino; G Marra; L Feo; A Barlattani
Journal:  Oral Implantol (Rome)       Date:  2011-01-13

5.  The effect of application time of two types of bone cement on the cement-bone interface strength.

Authors:  Ziad Dahabreh; Hannah Kalpana Phillips; Todd Stewart; Martin Stone
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-09-06

6.  The Kroc Foundation Conference on Functional Adaptation in Bone Tissue.

Authors: 
Journal:  Calcif Tissue Int       Date:  1984       Impact factor: 4.333

7.  Effects of washer on the stress distribution of mini-implant.

Authors:  Hyoung-Jun Jang; Soon-Yong Kwon; Seong-Hun Kim; Young-Guk Park; Su-Jung Kim
Journal:  Angle Orthod       Date:  2011-08-03       Impact factor: 2.079

8.  The polymer Polyactive as a bone-filling substance: an experimental study in rabbits.

Authors:  R Kuijer; S J Bouwmeester; M M Drees; D A Surtel; E A Terwindt-Rouwenhorst; A J Van Der Linden; C A Van Blitterswijk; S K Bulstra
Journal:  J Mater Sci Mater Med       Date:  1998-08       Impact factor: 3.896

9.  Quantitative histological analysis of bony ingrowth within the biomaterial Polyactive implanted in different bone locations: an experimental study in rabbits.

Authors:  S J Bouwmeester; R Kuijer; M M Sollie-Drees; A J van der Linden; S K Bulstra
Journal:  J Mater Sci Mater Med       Date:  1998-04       Impact factor: 3.896

10.  Retrograde tibial nailing: a minimally invasive and biomechanically superior alternative to angle-stable plate osteosynthesis in distal tibia fractures.

Authors:  Sebastian Kuhn; Philipp Appelmann; Dorothea Mehler; Philip Pairon; Pol M Rommens
Journal:  J Orthop Surg Res       Date:  2014-05-13       Impact factor: 2.359

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.