Literature DB >> 18302470

Comparison of stability between cylindrical and conical type mini-implants. Mechanical and histological properties.

Jong-Wan Kim1, Seung-Hak Baek, Tae-Woo Kim, Young-Il Chang.   

Abstract

OBJECTIVE: To investigate the mechanical and histologic properties of conical compared with cylindrical shaped mini-implants in terms of the success rate.
MATERIALS AND METHODS: The samples consisted of cylindrical and conical groups, and commonly had 1.6 mm diameter and 6.0 mm length (Jeil Medical Corporation, Seoul, Korea) placed in beagle dogs. The mechanical study for analyzing maximum insertion torque (MIT), maximum removal torque (MRT), and torque ratio (TR; MRT/MIT) in Sawbones (Pacific Research Laboratories Inc, Vashon, Wash), and the animal study for resonance frequency analysis (RFA) and histomorphometric analysis (bone-to-implant contact and bone area) in two beagle dogs were done. All measurements were statistically evaluated using independent t-tests to determine any difference in MIT, MRT, TR, RFA, bone-to-implant contact (BIC), and bone area (BA) between the cylindrical group and conical group. A P value less than 0.05 was considered significant.
RESULTS: The conical group showed significantly higher MIT and MRT than the cylindrical group in the mechanical study. However, there was no significant difference in RFA, BIC, and BA between the two groups in the animal and histomorphometric studies.
CONCLUSIONS: Although the conical shaped mini-implant could induce tight contact to the adjacent bone tissue and might produce good primary stability, the conical shape may need modification of the thread structure and insertion technique to reduce the excessive insertion torque while maintaining the high resistance to removal.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18302470     DOI: 10.2319/0003-3219(2008)078[0692:COSBCA]2.0.CO;2

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  27 in total

1.  Histomorphometric evaluation of the effects of various diode lasers and force levels on orthodontic mini screw stability.

Authors:  Merve Goymen; Eren Isman; Lale Taner; Mehmet Kurkcu
Journal:  Photomed Laser Surg       Date:  2015-01       Impact factor: 2.796

2.  A novel technique for measurement of orthodontic mini-implant stability using the Osstell ISQ device.

Authors:  Yara K Hosein; S Jeffrey Dixon; Amin S Rizkalla; Ali Tassi
Journal:  Angle Orthod       Date:  2018-11-01       Impact factor: 2.079

3.  Why are mini-implants lost: the value of the implantation technique!

Authors:  Fabio Lourenço Romano; Alberto Consolaro
Journal:  Dental Press J Orthod       Date:  2015 Jan-Feb

4.  Stability comparison between commercially available mini-implants and a novel design: part 1.

Authors:  Christine Hong; Haofu Lee; Richard Webster; Jinny Kwak; Benjamin M Wu; Won Moon
Journal:  Angle Orthod       Date:  2011-02-09       Impact factor: 2.079

5.  Effects of washer on the stress distribution of mini-implant.

Authors:  Hyoung-Jun Jang; Soon-Yong Kwon; Seong-Hun Kim; Young-Guk Park; Su-Jung Kim
Journal:  Angle Orthod       Date:  2011-08-03       Impact factor: 2.079

6.  Stress distributions of a bracket type orthodontic miniscrew and the surrounding bone under moment loadings: Three-dimensional finite element analysis.

Authors:  Shabnam Ajami; Ahmad Mina; Seyed Amin Nabavizadeh
Journal:  J Orthod Sci       Date:  2016 Apr-Jun

7.  Effect of rotation bump on removal torque of orthodontic mini-implants.

Authors:  Odontuya Gansukh; Jong-Wha Jeong; Jong-Wan Kim; Young-Kyun Kim; Jong-Ho Lee; Tae-Woo Kim
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2013-12-23

8.  Effects of predrilling depth and implant shape on the mechanical properties of orthodontic mini-implants during the insertion procedure.

Authors:  Keun-Chul Cho; Seung-Hak Baek
Journal:  Angle Orthod       Date:  2011-11-03       Impact factor: 2.079

9.  Angled-predrilling depth and mini-implant shape effects on the mechanical properties of self-drilling orthodontic mini-implants during the angled insertion procedure.

Authors:  Yoon-Young Heo; Keun-Chul Cho; Seung-Hak Baek
Journal:  Angle Orthod       Date:  2012-03-03       Impact factor: 2.079

10.  An in vitro study of factors affecting the primary stability of orthodontic mini-implants.

Authors:  Lindsy Holm; Susan J Cunningham; Aviva Petrie; Richard R J Cousley
Journal:  Angle Orthod       Date:  2012-05-07       Impact factor: 2.079

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.