Literature DB >> 21761249

Comparative evaluation of TonoPen AVIA, Goldmann applanation tonometry and non-contact tonometry.

Shibal Bhartiya1, Shveta Jindal Bali, Reetika Sharma, Neha Chaturvedi, Tanuj Dada.   

Abstract

To compare the tonometric recordings of the Tono-Pen AVIA (TPA) with intraocular pressure (IOP) recordings made with Goldmann applanation tonometry (GAT) and non-contact tonometry (NCT). This prospective, observational, comparative case series consisted of 180 eyes of 180 subjects (50 patients with glaucoma and 130 healthy controls). NCT was performed first, followed by GAT and TPA measurement after a 5-min break. The mean age of the patients enrolled in the study was 43.99±16.67 years. The limits of agreement (confidence interval 95%) as calculated from the Bland-Altman plots for TPA-GAT and TPA-NCT were +8.7 to -7.7 and +8.6 to -9.6 mmHg in glaucoma patients. In healthy subjects these values were +4.8 to -5.1 and +6.2 to -5.2 mmHg, respectively. TPA tends to overestimate IOP compared to GAT at central corneal thickness (CCT) greater than 520 μm and underestimate IOP at CCT less than 510 μm. TPA overestimates IOP in comparison to NCT in subjects with CCT greater than 456 μm. Due to wide limits of agreement, TPA cannot be used interchangeably with GAT and NCT in the serial monitoring of glaucoma patients. Central corneal thickness has a significant influence on the IOP readings measured by Tono-Pen AVIA.

Entities:  

Mesh:

Year:  2011        PMID: 21761249     DOI: 10.1007/s10792-011-9458-4

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.031


  26 in total

1.  Effect of corneal thickness on intraocular pressure measurements with the pneumotonometer, Goldmann applanation tonometer, and Tono-Pen.

Authors:  Archana Bhan; Andrew C Browning; Sunil Shah; Robin Hamilton; Dinesh Dave; Harminder S Dua
Journal:  Invest Ophthalmol Vis Sci       Date:  2002-05       Impact factor: 4.799

2.  [Comparison of precision of the TonoPenXL with the Goldmann and Draeger applanation tonometer in a sitting and recumbent position of the patients -- a clinical study on 251 eyes].

Authors:  Arne Viestenz; Berthold Lausen; Anselm M Jünemann; Christian Y Mardin
Journal:  Klin Monbl Augenheilkd       Date:  2002-11       Impact factor: 0.700

3.  [Further contribution to applanation tonometry].

Authors:  H GOLDMANN; T SCHMIDT
Journal:  Ophthalmologica       Date:  1961-06       Impact factor: 3.250

4.  [Applanation tonometry].

Authors:  H GOLDMANN; T SCHMIDT
Journal:  Ophthalmologica       Date:  1957-10       Impact factor: 3.250

5.  A comparison of four methods of tonometry: method agreement and interobserver variability.

Authors:  P-A Tonnu; T Ho; K Sharma; E White; C Bunce; D Garway-Heath
Journal:  Br J Ophthalmol       Date:  2005-07       Impact factor: 4.638

6.  Comparisons between Pascal dynamic contour tonometry, the TonoPen, and Goldmann applanation tonometry in patients with glaucoma.

Authors:  Maria L Salvetat; Marco Zeppieri; Claudia Tosoni; Paolo Brusini
Journal:  Acta Ophthalmol Scand       Date:  2007-05

7.  Evaluation of the Tono-Pen 2 and the X-Pert noncontact tonometers in cataract surgery.

Authors:  P Denis; J P Nordmann; V Bertin; J M Gayraud; L Laroche; H Saraux
Journal:  Ophthalmologica       Date:  1993       Impact factor: 3.250

8.  Accuracy of Goldmann tonometry in clinical practice.

Authors:  S Sudesh; M J Moseley; J R Thompson
Journal:  Acta Ophthalmol (Copenh)       Date:  1993-04

9.  Tono-Pen, a new tonometer.

Authors:  V Hessemer; R Rössler; K W Jacobi
Journal:  Int Ophthalmol       Date:  1989-01       Impact factor: 2.031

10.  Influence of corneal structure, corneal responsiveness, and other ocular parameters on tonometric measurement of intraocular pressure.

Authors:  Aimee Teo Broman; Nathan G Congdon; Karen Bandeen-Roche; Harry A Quigley
Journal:  J Glaucoma       Date:  2007 Oct-Nov       Impact factor: 2.503

View more
  8 in total

1.  Agreement between diurnal variations of intraocular pressure by Tono-Pen and Goldmann applanation tonometer in patients on topical anti-glaucoma medication.

Authors:  Shikha Gupta; Gautam Sinha; Reetika Sharma; Bhagabat Nayak; Bharat Patil; Bibhuti Kashyap; Abdul Shameer; Tanuj Dada
Journal:  Int Ophthalmol       Date:  2015-03-28       Impact factor: 2.031

2.  Utility of the Tono-Pen in Measuring Intraocular Pressure in Trinidad: A Cross-sectional Study.

Authors:  A Billy; P E David; A K Mahabir; C P Seerattan; J M Street; V D Walcott; R J Yarna; D C Murray; R G Maharaj
Journal:  West Indian Med J       Date:  2015-05-12       Impact factor: 0.171

3.  Effect of dorzolamide-timolol fixed combination prophylaxis on intraocular pressure spikes after intravitreal bevacizumab injection.

Authors:  Sehnaz Ozcaliskan; Faruk Ozturk; Pelin Yilmazbas; Ozlem Beyazyildiz
Journal:  Int J Ophthalmol       Date:  2015-06-18       Impact factor: 1.779

4.  [Differences in the measurement results of Goldmann applanation tonometry with and without fluorescein].

Authors:  N Arend; C Hirneiss; M Kernt
Journal:  Ophthalmologe       Date:  2014-03       Impact factor: 1.059

5.  Repeatability of intraocular pressure measurements with Icare PRO rebound, Tono-Pen AVIA, and Goldmann tonometers in sitting and reclining positions.

Authors:  Caterina Schweier; James V M Hanson; Jens Funk; Marc Töteberg-Harms
Journal:  BMC Ophthalmol       Date:  2013-09-05       Impact factor: 2.209

6.  Instability of 24-hour intraocular pressure fluctuation in healthy young subjects: a prospective, cross-sectional study.

Authors:  Yoo Kyung Song; Chang-Kyu Lee; Jiwon Kim; Samin Hong; Chan Yun Kim; Gong Je Seong
Journal:  BMC Ophthalmol       Date:  2014-11-04       Impact factor: 2.209

Review 7.  How should we measure intraocular pressure in the era of coronavirus disease 2019? Balancing infectious risk, cleaning requirements, and accuracy.

Authors:  Christine A Petersen; Andrew Chen; Philip P Chen
Journal:  Curr Opin Ophthalmol       Date:  2022-03-01       Impact factor: 3.761

8.  Early intraocular pressure changes following different keratoplasty techniques and association with cornea parameters and anterior chamber depth.

Authors:  Gulsah Gumus; Cigdem Altan; Yusuf Yildirim; Nilay Kandemir Beşek; Selim Genç; Ahmet Kirgiz; Gonul Karatas Durusoy; Alper Ağca
Journal:  Ther Adv Ophthalmol       Date:  2022-03-19
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.