Literature DB >> 26624589

Utility of the Tono-Pen in Measuring Intraocular Pressure in Trinidad: A Cross-sectional Study.

A Billy1, P E David1, A K Mahabir1, C P Seerattan1, J M Street1, V D Walcott1, R J Yarna1, D C Murray2, R G Maharaj3.   

Abstract

AIM: To determine the sensitivity and specificity of the Reichert™ Tono-Pen AVIA® when used by novice medical students in an ethnically diverse population in Trinidad. SUBJECTS AND
METHOD: Participants were residents of Trinidad between the ages of 20 and 90 years attending the Ophthalmology Clinic at the Eric Williams Medical Sciences Complex (EWMSC). Intraocular pressure (IOP) was measured using the Goldmann applanation tonometer (the gold standard) for ophthalmology clinic patients as part of their routine care. Intraocular pressure measurements were then taken using the Tono-Pen.
RESULTS: One hundred persons participated, consisting of Indo-Trinidadians (55%), Afro-Trinidadians (36%), Mixed (8%) and 1% of Caucasian descent. Fourteen per cent reported a diagnosis of glaucoma, with 70.6% of these being of African descent. One hundred and ninety-eight readings of IOP were taken. At a cut-off point of 21 mmHg, there were nine true positives, four false positives, seven false negatives and 178 true negatives. The sensitivity and specificity were found to be 56.3% (95% CI 33.2, 76.9) and 97.8% (95% CI 94.5, 99.1), respectively. The positive predictive value was calculated as 69.2% (95% CI 42.4, 87.3) while the negative predictive value was 96.2% (95% CI 92.4, 98.2). The prevalence of elevated IOP in this population was 8.1% (95% CI 4.8, 13.0). The likelihood ratio of a positive result was calculated to be 25.6 (95% CI 8.6, 73.9).
CONCLUSION: The high specificity and negative predictive value suggests that the Tono-Pen can be used with minimal training, and can prove beneficial at the primary care level in the exclusion of increased IOP in an ethnically diverse high-risk Caribbean population.

Entities:  

Year:  2015        PMID: 26624589      PMCID: PMC4909069          DOI: 10.7727/wimj.2014.125

Source DB:  PubMed          Journal:  West Indian Med J        ISSN: 0043-3144            Impact factor:   0.171


  22 in total

1.  Causes of visual loss and their risk factors: an incidence summary from the Barbados Eye Studies.

Authors:  M Cristina Leske; Suh-Yuh Wu; Barbara Nemesure; Anselm Hennis
Journal:  Rev Panam Salud Publica       Date:  2010-04

2.  Screening for glaucoma in general practice.

Authors:  M Lewis
Journal:  Br J Gen Pract       Date:  1991-02       Impact factor: 5.386

Review 3.  Open-angle glaucoma: Tips for earlier detection and treatment selection.

Authors:  Ahmad A Aref; Brian P Schmitt
Journal:  J Fam Pract       Date:  2005-02       Impact factor: 0.493

4.  Global data on visual impairment in the year 2002.

Authors:  Serge Resnikoff; Donatella Pascolini; Daniel Etya'ale; Ivo Kocur; Ramachandra Pararajasegaram; Gopal P Pokharel; Silvio P Mariotti
Journal:  Bull World Health Organ       Date:  2004-12-14       Impact factor: 9.408

5.  In vivo validation of the new Tonopen AVIA tonometer using manometers placed in the anterior chamber and the vitreous cavity under various vitreous conditions.

Authors:  Hyun Seung Yang; June-Gone Kim; Hong Seok Ko; Kyoung Sub Lee; Hoon Jae Won
Journal:  Curr Eye Res       Date:  2013-11-11       Impact factor: 2.424

Review 6.  Collaborative normal tension glaucoma study.

Authors:  Douglas R Anderson
Journal:  Curr Opin Ophthalmol       Date:  2003-04       Impact factor: 3.761

7.  Reduction of intraocular pressure and glaucoma progression: results from the Early Manifest Glaucoma Trial.

Authors:  Anders Heijl; M Cristina Leske; Bo Bengtsson; Leslie Hyman; Boel Bengtsson; Mohamed Hussein
Journal:  Arch Ophthalmol       Date:  2002-10

8.  Incident open-angle glaucoma and intraocular pressure.

Authors:  B Nemesure; R Honkanen; A Hennis; S Y Wu; M Cristina Leske
Journal:  Ophthalmology       Date:  2007-06-20       Impact factor: 12.079

9.  Early detection of chronic simple glaucoma in general practice.

Authors:  M A Phillips
Journal:  J R Coll Gen Pract       Date:  1977-10

10.  Accuracy of Goldmann, ocular response analyser, Pascal and TonoPen XL tonometry in keratoconic and normal eyes.

Authors:  S P Mollan; J S Wolffsohn; M Nessim; M Laiquzzaman; S Sivakumar; S Hartley; S Shah
Journal:  Br J Ophthalmol       Date:  2008-08-29       Impact factor: 4.638

View more
  1 in total

Review 1.  Portable hardware & software technologies for addressing ophthalmic health disparities: A systematic review.

Authors:  Margarita Labkovich; Megan Paul; Eliott Kim; Randal A Serafini; Shreyas Lakhtakia; Aly A Valliani; Andrew J Warburton; Aashay Patel; Davis Zhou; Bonnie Sklar; James Chelnis; Ebrahim Elahi
Journal:  Digit Health       Date:  2022-05-06
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.