X-ray imaging performance of structured cesium iodide scintillators.

Wei Zhao1, Goran Ristic, J A Rowlands.   

Abstract

Columnar structured cesium iodide (CsI) scintillators doped with Thallium (Tl) have been used extensively for indirect x-ray imaging detectors. The purpose of this paper is to develop a methodology for systematic investigation of the inherent imaging performance of CsI as a function of thickness and design type. The results will facilitate the optimization of CsI layer design for different x-ray imaging applications, and allow validation of physical models developed for the light channeling process in columnar CsI layers. CsI samples of different types and thicknesses were obtained from the same manufacturer. They were optimized either for light output (HL) or image resolution (HR), and the thickness ranged between 150 and 600 microns. During experimental measurements, the CsI samples were placed in direct contact with a high resolution CMOS optical sensor with a pixel pitch of 48 microns. The modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) of the detector with different CsI configurations were measured experimentally. The aperture function of the CMOS sensor was determined separately in order to estimate the MTF of CsI alone. We also measured the pulse height distribution of the light output from both the HL and HR CsI at different x-ray energies, from which the x-ray quantum efficiency, Swank factor and x-ray conversion gain were determined. Our results showed that the MTF at 5 cycles/mm for the HR type was 50% higher than for the HL. However, the HR layer produces approximately 36% less light output. The Swank factor below K-edge was 0.91 and 0.93 for the HR and HL types, respectively, thus their DQE(0) were essentially identical. The presampling MTF decreased as a function of thickness L. The universal MTF, i.e., MTF plotted as a function of the product of spatial frequency f and CsI thickness L, increased as a function of L. This indicates that the light channeling process in CsI improved the MTF of thicker layers more significantly than for the thinner ones.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15487742     DOI: 10.1118/1.1782676

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  25 in total

1.  EMCCD-based high resolution dynamic x-ray detector for neurovascular interventions.

Authors:  P Sharma; S N Swetadri Vasan; A Jain; A Panse; A H Titus; A N Cartwright; D R Bednarek; S Rudin
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2011

2.  Singular value description of a digital radiographic detector: theory and measurements.

Authors:  Iacovos S Kyprianou; Aldo Badano; Brandon D Gallas; Kyle J Myers
Journal:  Med Phys       Date:  2008-10       Impact factor: 4.071

3.  Cascaded systems analysis of noise and detectability in dual-energy cone-beam CT.

Authors:  Grace J Gang; Wojciech Zbijewski; J Webster Stayman; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2012-08       Impact factor: 4.071

4.  Multi-layer imager design for mega-voltage spectral imaging.

Authors:  Marios Myronakis; Yue-Houng Hu; Rony Fueglistaller; Adam Wang; Paul Baturin; Pascal Huber; Daniel Morf; Josh Star-Lack; Ross Berbeco
Journal:  Phys Med Biol       Date:  2018-05-10       Impact factor: 3.609

5.  New light-amplifier-based detector designs for high spatial resolution and high sensitivity CBCT mammography and fluoroscopy.

Authors:  Stephen Rudin; Andrew T Kuhls; Girijesh K Yadava; Gaurav C Josan; Ye Wu; Ravishankar N Chityala; Hussain S Rangwala; N Ciprian Ionita; Kenneth R Hoffmann; Daniel R Bednarek
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2006-12-02

6.  Accurate MTF measurement in digital radiography using noise response.

Authors:  Andrew Kuhls-Gilcrist; Amit Jain; Daniel R Bednarek; Kenneth R Hoffmann; Stephen Rudin
Journal:  Med Phys       Date:  2010-02       Impact factor: 4.071

7.  A theoretical and experimental evaluation of the microangiographic fluoroscope: A high-resolution region-of-interest x-ray imager.

Authors:  Amit Jain; D R Bednarek; Ciprian Ionita; S Rudin
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

8.  Progress in electron-multiplying CCD (EMCCD) based, high-resolution, high-sensitivity x-ray detector for fluoroscopy and radiography.

Authors:  Andrew T Kuhls; Girijesh Yadava; Vikas Patel; Daniel R Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2007

9.  Experimental validation of Monte Carlo (MANTIS) simulated x-ray response of columnar CsI scintillator screens.

Authors:  Melanie Freed; Stuart Miller; Katherine Tang; Aldo Badano
Journal:  Med Phys       Date:  2009-11       Impact factor: 4.071

10.  Physics considerations in MV-CBCT multi-layer imager design.

Authors:  Yue-Houng Hu; Rony Fueglistaller; Marios Myronakis; Joerg Rottmann; Adam Wang; Daniel Shedlock; Daniel Morf; Paul Baturin; Pascal Huber; Josh Star-Lack; Ross Berbeco
Journal:  Phys Med Biol       Date:  2018-06-20       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.