Does kV-MV dual-energy computed tomography have an advantage in determining proton stopping power ratios in patients?

M Yang1, G Virshup, J Clayton, X R Zhu, R Mohan, L Dong.   

Abstract

Conventional kilovoltage (kV) x-ray-based dual-energy CT (DECT) imaging using two different x-ray energy spectra is sensitive to image noise and beam hardening effects. The purpose of this study was to evaluate the theoretical advantage of the DECT method for determining proton stopping power ratios (SPRs) using a combination of kV and megavoltage (MV) x-ray energies. We investigated three representative x-ray energy pairs: 100 and 140 kVp comprised the kV-kV pair, 100 kVp and 1 MV comprised the kV-MV pair, and two 1 MV x-ray beams-one with and one without external filtration-comprised the MV-MV pair. The SPRs of 34 human tissues were determined using the DECT method with these three x-ray energy pairs. Small perturbations were introduced into the CT numbers and x-ray spectra used for the DECT calculation to simulate the effects of random noise and beam hardening. An error propagation analysis was performed on the DECT calculation algorithm to investigate the propagation of CT number uncertainty to final SPR estimation and to suggest the best x-ray energy combination. We found that the DECT method using each of the three beam pairs achieved similar accuracy in determining the SPRs of human tissues in ideal conditions. However, when CT number uncertainties and artifacts such as imaging noise and beam hardening effects were considered, the kV-MV DECT improved the accuracy of SPR estimation substantially over the kV-kV or MV-MV DECT methods. Furthermore, our error propagation analysis showed that the combination of 100 kVp and 1 MV beams was close to the optimal selection when using the DECT method to determine SPRs. Overall, the kV-MV combination makes the DECT method more robust in resolving the effective atomic numbers for biological tissues than the traditional kV-kV DECT method.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21719949      PMCID: PMC3144258          DOI: 10.1088/0031-9155/56/14/017

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  12 in total

1.  Methodologies and tools for proton beam design for lung tumors.

Authors:  M F Moyers; D W Miller; D A Bush; J D Slater
Journal:  Int J Radiat Oncol Biol Phys       Date:  2001-04-01       Impact factor: 7.038

2.  Segmented crystalline scintillators: an initial investigation of high quantum efficiency detectors for megavoltage x-ray imaging.

Authors:  Amit Sawant; Larry E Antonuk; Youcef El-Mohri; Qihua Zhao; Yixin Li; Zhong Su; Yi Wang; Jin Yamamoto; Hong Du; Ian Cunningham; Misha Klugerman; Kanai Shah
Journal:  Med Phys       Date:  2005-10       Impact factor: 4.071

3.  On two-parameter models of photon cross sections: application to dual-energy CT imaging.

Authors:  Jeffrey F Williamson; Sicong Li; Slobodan Devic; Bruce R Whiting; Fritz A Lerma
Journal:  Med Phys       Date:  2006-11       Impact factor: 4.071

4.  Monte Carlo investigations of megavoltage cone-beam CT using thick, segmented scintillating detectors for soft tissue visualization.

Authors:  Yi Wang; Larry E Antonuk; Youcef El-Mohri; Qihua Zhao; Amit Sawant; Hong Du
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

5.  High-DQE EPIDs based on thick, segmented BGO and CsI:Tl scintillators: performance evaluation at extremely low dose.

Authors:  Yi Wang; Larry E Antonuk; Qihua Zhao; Youcef El-Mohri; Louis Perna
Journal:  Med Phys       Date:  2009-12       Impact factor: 4.071

6.  The calibration of CT Hounsfield units for radiotherapy treatment planning.

Authors:  U Schneider; E Pedroni; A Lomax
Journal:  Phys Med Biol       Date:  1996-01       Impact factor: 3.609

7.  Theoretical variance analysis of single- and dual-energy computed tomography methods for calculating proton stopping power ratios of biological tissues.

Authors:  M Yang; G Virshup; J Clayton; X R Zhu; R Mohan; L Dong
Journal:  Phys Med Biol       Date:  2010-02-10       Impact factor: 3.609

8.  Improving accuracy of electron density measurement in the presence of metallic implants using orthovoltage computed tomography.

Authors:  Ming Yang; Gary Virshup; Radhe Mohan; Chris C Shaw; X Ronald Zhu; Lei Dong
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

9.  Ion stopping powers and CT numbers.

Authors:  Michael F Moyers; Milind Sardesai; Sean Sun; Daniel W Miller
Journal:  Med Dosim       Date:  2009-06-21       Impact factor: 1.482

10.  Average soft-tissue and bone models for use in radiation dosimetry.

Authors:  D R White; H Q Woodard; S M Hammond
Journal:  Br J Radiol       Date:  1987-09       Impact factor: 3.039

View more
  13 in total

1.  Material elemental decomposition in dual and multi-energy CT via a sparsity-dictionary approach for proton stopping power ratio calculation.

Authors:  Chenyang Shen; Bin Li; Liyuan Chen; Ming Yang; Yifei Lou; Xun Jia
Journal:  Med Phys       Date:  2018-02-23       Impact factor: 4.071

2.  Intensity modulated proton therapy.

Authors:  H M Kooy; C Grassberger
Journal:  Br J Radiol       Date:  2015-05-27       Impact factor: 3.039

Review 3.  Image guidance in proton therapy for lung cancer.

Authors:  Miao Zhang; Wei Zou; Boon-Keng Kevin Teo
Journal:  Transl Lung Cancer Res       Date:  2018-04

4.  Systematic analysis of the impact of imaging noise on dual-energy CT-based proton stopping power ratio estimation.

Authors:  Hugh H C Lee; Bin Li; Xinhui Duan; Linghong Zhou; Xun Jia; Ming Yang
Journal:  Med Phys       Date:  2019-04-01       Impact factor: 4.071

Review 5.  Empowering Intensity Modulated Proton Therapy Through Physics and Technology: An Overview.

Authors:  Radhe Mohan; Indra J Das; Clifton C Ling
Journal:  Int J Radiat Oncol Biol Phys       Date:  2017-10-01       Impact factor: 7.038

6.  Comprehensive analysis of proton range uncertainties related to patient stopping-power-ratio estimation using the stoichiometric calibration.

Authors:  Ming Yang; X Ronald Zhu; Peter C Park; Uwe Titt; Radhe Mohan; Gary Virshup; James E Clayton; Lei Dong
Journal:  Phys Med Biol       Date:  2012-06-07       Impact factor: 3.609

7.  Physical density estimations of single- and dual-energy CT using material-based forward projection algorithm: a simulation study.

Authors:  Kai-Wen Li; Daiyu Fujiwara; Akihiro Haga; Huisheng Liu; Li-Sheng Geng
Journal:  Br J Radiol       Date:  2021-09-29       Impact factor: 3.039

8.  Site-specific range uncertainties caused by dose calculation algorithms for proton therapy.

Authors:  J Schuemann; S Dowdell; C Grassberger; C H Min; H Paganetti
Journal:  Phys Med Biol       Date:  2014-07-03       Impact factor: 3.609

9.  Spectral imaging using clinical megavoltage beams and a novel multi-layer imager.

Authors:  Marios Myronakis; Rony Fueglistaller; Joerg Rottmann; Yue-Houng Hu; Adam Wang; Paul Baturin; Pascal Huber; Daniel Morf; Josh Star-Lack; Ross Berbeco
Journal:  Phys Med Biol       Date:  2017-11-14       Impact factor: 3.609

10.  Comprehensive analysis of proton range uncertainties related to stopping-power-ratio estimation using dual-energy CT imaging.

Authors:  B Li; H C Lee; X Duan; C Shen; L Zhou; X Jia; M Yang
Journal:  Phys Med Biol       Date:  2017-08-09       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.