Systematic analysis of the impact of imaging noise on dual-energy CT-based proton stopping power ratio estimation.

Hugh H C Lee1, Bin Li2, Xinhui Duan3, Linghong Zhou4, Xun Jia1, Ming Yang1.   

Abstract

PURPOSE: Dual-energy CT (DECT) has been shown to have a great potential in reducing the uncertainty in proton stopping power ratio (SPR) estimation, when compared to current standard method - the stoichiometric method based on single-energy CT (SECT). However, a few recent studies indicated that imaging noise may have a substantial impact on the performance of the DECT-based approach, especially at a high noise level. The goal of this study is to quantify the uncertainty in SPR and range estimation caused by noise in the DECT-based approach under various conditions.
METHODS: Two widely referred parametric DECT methods were studied: the Hünemohr-Saito (HS) method and the Bourque method. Both methods were calibrated using Gammex tissue substitute inserts scanned on the Siemens Force DECT scanner. An energy pair of 80 and 150 kVp with a tin filter was chosen to maximize the spectral separation. After calibrating the model with the Gammex phantom, CT numbers were synthesized using the density and elemental composition from ICRU 44 human tissues to be used as a reference, in order to evaluate the impact of noise alone while putting aside other sources of uncertainty. Gaussian noise was introduced to the reference CT numbers and its impact was measured with the difference between estimated SPR and its noiseless reference SPR. The uncertainty caused by noise was divided into two independent categories: shift of the mean SPR and variation of SPR. Their overall impact on range uncertainty was evaluated on homogeneous and heterogeneous tissue samples of various water equivalent path lengths (WEPL).
RESULTS: Due to the algorithms being nonlinear and/or having hard thresholds in the CT number to SPR mapping, noise in the CT numbers induced a shift in the mean SPR from its noiseless reference SPR. The degree of the mean shift was dependent on the algorithm and tissue type, but its impact on the SPR uncertainty was mostly small compared to the variation. All mean shifts observed in this study were within 0.5% at a noise level of 2%. The ratio of the influence of variation to mean shift was mostly greater than 1, indicating that variation more likely determined the uncertainty caused by noise. Overall, the range uncertainty (95th percentile) caused by noise was within 1.2% and 1.0% for soft and bone tissues, respectively, at 2% noise with 50 voxels. This value can be considered an upper limit as more voxels and lower noise level rapidly decreased the uncertainty.
CONCLUSIONS: We have systematically evaluated the impact of noise to the DECT-based SPR estimation and identified under various conditions that the variation caused by noise is the dominant uncertainty-contributing component. We conclude that, based on the noise level and tumor depth, it is important to estimate and include the uncertainty due to noise in estimating the overall range uncertainty before implementing a small margin in the range of 1%.
© 2019 American Association of Physicists in Medicine.

Entities:  

Keywords:  dual-energy CT (DECT); effective atomic number (EAN); electron density ratio (EDR); random noise; stopping power ratio (SPR) estimation

Mesh:

Substances:

Year:  2019        PMID: 30883827      PMCID: PMC6510613          DOI: 10.1002/mp.13493

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  27 in total

1.  Potential of dual-energy subtraction for converting CT numbers to electron density based on a single linear relationship.

Authors:  Masatoshi Saito
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

2.  A linear, separable two-parameter model for dual energy CT imaging of proton stopping power computation.

Authors:  Dong Han; Jeffrey V Siebers; Jeffrey F Williamson
Journal:  Med Phys       Date:  2016-01       Impact factor: 4.071

3.  Experimental verification of ion stopping power prediction from dual energy CT data in tissue surrogates.

Authors:  Nora Hünemohr; Bernhard Krauss; Christoph Tremmel; Benjamin Ackermann; Oliver Jäkel; Steffen Greilich
Journal:  Phys Med Biol       Date:  2013-12-12       Impact factor: 3.609

4.  The influence of CT image noise on proton range calculation in radiotherapy planning.

Authors:  Alexei V Chvetsov; Sandra L Paige
Journal:  Phys Med Biol       Date:  2010-02-24       Impact factor: 3.609

5.  Does kV-MV dual-energy computed tomography have an advantage in determining proton stopping power ratios in patients?

Authors:  M Yang; G Virshup; J Clayton; X R Zhu; R Mohan; L Dong
Journal:  Phys Med Biol       Date:  2011-06-30       Impact factor: 3.609

Review 6.  Dual energy CT in radiotherapy: Current applications and future outlook.

Authors:  Wouter van Elmpt; Guillaume Landry; Marco Das; Frank Verhaegen
Journal:  Radiother Oncol       Date:  2016-03-11       Impact factor: 6.280

7.  Theoretical variance analysis of single- and dual-energy computed tomography methods for calculating proton stopping power ratios of biological tissues.

Authors:  M Yang; G Virshup; J Clayton; X R Zhu; R Mohan; L Dong
Journal:  Phys Med Biol       Date:  2010-02-10       Impact factor: 3.609

8.  Comprehensive analysis of proton range uncertainties related to patient stopping-power-ratio estimation using the stoichiometric calibration.

Authors:  Ming Yang; X Ronald Zhu; Peter C Park; Uwe Titt; Radhe Mohan; Gary Virshup; James E Clayton; Lei Dong
Journal:  Phys Med Biol       Date:  2012-06-07       Impact factor: 3.609

9.  Comparison of proton therapy treatment planning for head tumors with a pencil beam algorithm on dual and single energy CT images.

Authors:  Nace Hudobivnik; Florian Schwarz; Thorsten Johnson; Linda Agolli; George Dedes; Thomas Tessonnier; Frank Verhaegen; Christian Thieke; Claus Belka; Wieland H Sommer; Katia Parodi; Guillaume Landry
Journal:  Med Phys       Date:  2016-01       Impact factor: 4.071

10.  A stoichiometric calibration method for dual energy computed tomography.

Authors:  Alexandra E Bourque; Jean-François Carrier; Hugo Bouchard
Journal:  Phys Med Biol       Date:  2014-04-02       Impact factor: 3.609

View more
  5 in total

Review 1.  Status and innovations in pre-treatment CT imaging for proton therapy.

Authors:  Patrick Wohlfahrt; Christian Richter
Journal:  Br J Radiol       Date:  2019-11-11       Impact factor: 3.039

Review 2.  Adaptive proton therapy.

Authors:  Harald Paganetti; Pablo Botas; Gregory C Sharp; Brian Winey
Journal:  Phys Med Biol       Date:  2021-11-15       Impact factor: 3.609

3.  Improved accuracy of relative electron density and proton stopping power ratio through CycleGAN machine learning.

Authors:  Jessica Scholey; Luciano Vinas; Vasant Kearney; Sue Yom; Peder Eric Zufall Larson; Martina Descovich; Atchar Sudhyadhom
Journal:  Phys Med Biol       Date:  2022-05-02       Impact factor: 4.174

4.  On the molecular relationship between Hounsfield Unit (HU), mass density, and electron density in computed tomography (CT).

Authors:  Atchar Sudhyadhom
Journal:  PLoS One       Date:  2020-12-31       Impact factor: 3.240

5.  Technical Note: A methodology for improved accuracy in stopping power estimation using MRI and CT.

Authors:  Jessica E Scholey; Dharshan Chandramohan; Tarun Naren; William Liu; Peder Eric Zufall Larson; Atchar Sudhyadhom
Journal:  Med Phys       Date:  2020-11-20       Impact factor: 4.071

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.