OBJECTIVES: Advances in ceramic processing techniques enable clinicians and ceramists to fabricate all-ceramic fixed partial dentures (FPDs) for posterior regions using high-strength yttria-stabilized tetragonal zirconia polycrystals (Y-TZP). However, failures occur in ceramic FPDs due to their design. The objectives of this study were to determine the site of crack initiation and the causes of fracture in clinically failed zirconia-based ceramic FPDs.
METHODS: Five clinically failed four-unit Y-TZP-based FPDs (Cercon ceramics, DeguDent GmbH, Hanau, Germany) were retrieved and analyzed. The fragments containing the fracture origins in the veneers (Cercon Ceram S Veneering Ceramic, DeguDent GmbH, Hanau, Germany) of two samples were missing but the rest of veneer structures were present. The other three samples had their veneers intact. Fracture surfaces were examined using fractographic techniques, utilizing both optical and scanning electron microscopes (SEM). Quantitative fractography and fracture mechanics principles were used to estimate the stresses at failure.
RESULTS: Primary fractures initiated from the gingival surfaces of connectors at veneer surfaces in four out of the five samples. However, critical flaw sizes could be measured in three of the five cases since fracture origins were lost in the remaining two due to local fragmentation at the crack initiation site. Delaminations between glass veneer and zirconia core were observed in Y-TZP-based FPDs and a secondary fracture initiated from the zirconia core. Secondary fracture controlled the ultimate failure. Failure stresses of the fixed partial dentures that failed due to zirconia fracture ranged from 379 to 501 MPa. Fractures that had origins on the glass veneer surface had failure stresses between 31 and 38 MPa. SIGNIFICANCE: Primary fractures in clinically failed Y-TZP-based FPDs initiated from the veneer surfaces. Interfacial delamination in glass veneer/zirconia core bilayer dental ceramic structures controlled the secondary fracture initiation sites and failure stresses in Y-TZP-based fixed partial dentures.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18282595     DOI: 10.1016/j.dental.2007.12.006

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  19 in total

1.  Shear bond strength between an indirect composite layering material and feldspathic porcelain-coated zirconia ceramics.

Authors:  Ryosuke Fushiki; Futoshi Komine; Markus B Blatz; Mai Koizuka; Kohei Taguchi; Hideo Matsumura
Journal:  Clin Oral Investig       Date:  2011-12-06       Impact factor: 3.573

2.  Damage and reliability of Y-TZP after cementation surface treatment.

Authors:  P C Guess; Y Zhang; J-W Kim; E D Rekow; V P Thompson
Journal:  J Dent Res       Date:  2010-03-30       Impact factor: 6.116

3.  Finite element analysis to compare stress distribution of connector of lithia disilicate-reinforced glass-ceramic and zirconia-based fixed partial denture.

Authors:  Jie Lin; Akikazu Shinya; Harunori Gomi; Akiyoshi Shinya
Journal:  Odontology       Date:  2011-06-21       Impact factor: 2.634

Review 4.  Performance of dental ceramics: challenges for improvements.

Authors:  E D Rekow; N R F A Silva; P G Coelho; Y Zhang; P Guess; V P Thompson
Journal:  J Dent Res       Date:  2011-01-11       Impact factor: 6.116

5.  Flexural strength and failure modes of layered ceramic structures.

Authors:  Márcia Borba; Maico D de Araújo; Erick de Lima; Humberto N Yoshimura; Paulo F Cesar; Jason A Griggs; Alvaro Della Bona
Journal:  Dent Mater       Date:  2011-10-06       Impact factor: 5.304

6.  Fatigue of zirconia and dental bridge geometry: Design implications.

Authors:  G D Quinn; A R Studart; C Hebert; J R VerHoef; D Arola
Journal:  Dent Mater       Date:  2010-09-01       Impact factor: 5.304

7.  Step-stress analysis for predicting dental ceramic reliability.

Authors:  Márcia Borba; Paulo F Cesar; Jason A Griggs; Alvaro Della Bona
Journal:  Dent Mater       Date:  2013-07-02       Impact factor: 5.304

8.  Reliability and failure modes of implant-supported zirconium-oxide fixed dental prostheses related to veneering techniques.

Authors:  Marta Baldassarri; Yu Zhang; Van P Thompson; Elizabeth D Rekow; Christian F J Stappert
Journal:  J Dent       Date:  2011-04-28       Impact factor: 4.379

9.  Interfacial toughness of bilayer dental ceramics based on a short-bar, chevron-notch test.

Authors:  Chuchai Anunmana; Kenneth J Anusavice; John J Mecholsky
Journal:  Dent Mater       Date:  2009-10-08       Impact factor: 5.304

10.  Fatigue loading and R-curve behavior of a dental glass-ceramic with multiple flaw distributions.

Authors:  Gaurav V Joshi; Yuanyuan Duan; Alvaro Della Bona; Thomas J Hill; Kenneth St John; Jason A Griggs
Journal:  Dent Mater       Date:  2013-09-10       Impact factor: 5.304

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.