Literature DB >> 25200313

Structural stability of posterior retainer design for resin-bonded prostheses: a 3D finite element study.

Jie Lin1,2, Zhiqiang Zheng3, Akikazu Shinya4, Jukka Pekka Matinlinna5, Michael George Botelho6, Akiyoshi Shinya7.   

Abstract

The purpose of this in vitro study was to compare the stress distribution and natural frequency of different shape and thickness retainer designs for maxillary posterior resin-bonded prostheses using finite element (FE) method. A 3D FE model of a three unit posterior resin-bonded prosthesis analysis model was generated. Three different shaped retainer designs, viz. C-shaped (three axial surface wraparounds), D-shaped (three axial surface wraparounds with central groove) and O-shaped (360° wraparounds), and three different thicknesses, viz., 0.4, 0.8, and 1.2 mm, resin-bonded prostheses were used in this study. The resin-bonded prosthesis analysis model was imported into an FE analysis software (ANSYS 10.0, ANSYS, USA) and attribution of material properties. The nodes at the bottom surface of the roots were assigned fixed zero displacement in the three spatial dimensions. A simulated angle of 45° loading of a 100 N force was applied to the node of the pontic lingual cusp surface. The stress distributions and corresponding natural frequencies were analyzed and resolved. The C-shaped retainer for 0.4 mm thickness recorded the greatest von Mises stresses of 71.4 MPa for all three groups. C-shaped, D-shaped and O-shaped retainer presented natural frequencies 3,988, 7,754, and 10,494 Hz, respectively. D-shaped retainer and O-shaped retainer increased natural frequencies and structural rigidity over the traditional C-shaped retainer. The maximum von Mises stresses values of the remaining tooth and prosthesis decreased with greater retainer thickness. D-shaped retainer and O-shaped retainer increased natural frequencies and structural rigidity over the traditional C-shaped retainer.

Entities:  

Keywords:  Finite element analysis; Natural frequency; Resin-bonded prosthesis; Retainer design

Mesh:

Substances:

Year:  2014        PMID: 25200313     DOI: 10.1007/s10266-014-0173-2

Source DB:  PubMed          Journal:  Odontology        ISSN: 1618-1247            Impact factor:   2.634


  24 in total

1.  Vibration analysis of maxillary removable partial denture frameworks.

Authors:  T Inoue; M Oki; P Phankosol; T Ohyama; H Taniguchi
Journal:  J Oral Rehabil       Date:  2002-04       Impact factor: 3.837

2.  Factors influencing the resonance frequency of dental implants.

Authors:  Haw-Ming Huang; Ching-Lai Chiu; Ching-Ying Yeh; Sheng-Yang Lee
Journal:  J Oral Maxillofac Surg       Date:  2003-10       Impact factor: 1.895

3.  Accuracy of three-dimensional finite element modeling using two different dental cone beam computed tomography systems.

Authors:  Aki Hasegawa; Akikazu Shinya; Lippo V J Lassila; Daiichiro Yokoyama; Yuji Nakasone; Pekka K Vallittu; Akiyoshi Shinya
Journal:  Odontology       Date:  2012-06-23       Impact factor: 2.634

4.  Five-year survival of 3-unit fiber-reinforced composite fixed partial dentures in the posterior area.

Authors:  Céleste C M van Heumen; Johanna Tanner; Jan W V van Dijken; Ronald Pikaar; Lippo V J Lassila; Nico H J Creugers; Pekka K Vallittu; Cees M Kreulen
Journal:  Dent Mater       Date:  2010-07-17       Impact factor: 5.304

5.  Multi-factorial retainer design analysis of posterior resin-bonded fixed partial dentures: a finite element study.

Authors:  Chun-Li Lin; Kuang-Wei Hsu; Chun-Hsien Wu
Journal:  J Dent       Date:  2005-03-04       Impact factor: 4.379

6.  Three-dimensional finite element analysis of metal and FRC adhesive fixed dental prostheses.

Authors:  Akikazu Shinya; Daiichiro Yokoyama; Lippo V J Lassila; Akiyoshi Shinya; Pekka K Vallittu
Journal:  J Adhes Dent       Date:  2008-10       Impact factor: 2.359

7.  Effect of tooth preparation design on bond strengths of resin-bonded prostheses: a pilot study.

Authors:  M A el Salam Shakal; P Pfeiffer; R D Hilgers
Journal:  J Prosthet Dent       Date:  1997-03       Impact factor: 3.426

8.  Finite element analysis to compare stress distribution of gold alloy, lithium-disilicate reinforced glass ceramic and zirconia based fixed partial denture.

Authors:  Zhiqiang Zheng; Jie Lin; Akikazu Shinya; Jukka P Matinlinna; Michael G Botelho; Akiyoshi Shinya
Journal:  J Investig Clin Dent       Date:  2012-09-13

9.  A retrospective clinical evaluation of two-unit cantilevered resin-bonded fixed partial dentures.

Authors:  Michael G Botelho; Katherine C M Leung; Hyden Ng; Kingsley Chan
Journal:  J Am Dent Assoc       Date:  2006-06       Impact factor: 3.634

10.  Evaluation of the effects of different groove length and thickness of the retainers on the retention of maxillary anterior base metal resin bonded retainers-an in vitro study.

Authors:  Anoop Nair; K M Regish; N P Patil; D R Prithviraj
Journal:  J Clin Exp Dent       Date:  2012-04-01
View more
  2 in total

1.  Effect of different surface treatments and retainer designs on the retention of posterior Pd-Ag porcelain-fused-to-metal resin-bonded fixed partial dentures.

Authors:  Xiwen Chen; Yixin Zhang; Jinru Zhou; Chenfeng Chen; Zhimin Zhu; Lei Li
Journal:  Exp Ther Med       Date:  2017-12-14       Impact factor: 2.447

2.  Effect of different restorative crown design and materials on stress distribution in endodontically treated molars: a finite element analysis study.

Authors:  Jie Lin; Zhenxiang Lin; Zhiqiang Zheng
Journal:  BMC Oral Health       Date:  2020-08-18       Impact factor: 2.757

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.