Literature DB >> 12741496

An improved analytical detector response function model for multilayer small-diameter PET scanners.

D Strul1, R B Slates, M Dahlbom, S R Cherry, P K Marsden.   

Abstract

The optimization of spatial resolution is a critical consideration in the design of small-diameter positron emission tomography (PET) scanners for animal imaging, and is often addressed with Monte Carlo simulations. As a faster and simpler solution, we have developed a new analytical model of the PET detector response function, and implemented the model for a small single-slice, multilayer PET scanner. The accuracy of the model has been assessed by comparison with both Monte Carlo simulations and experimental measurements published in the literature. Results from the analytical model agreed well with the Monte Carlo method, being noise free and two to three orders of magnitude faster. The only major discrepancy was a slight underestimation of the width of the point spread function by the analytical method as inter-crystal scatter is neglected. We observed good agreement between the predictions of the model and experimental measurements. For two large-diameter scanners additional discrepancies were seen due to photon acollinearity, which is not considered in the model. We have shown that the simple and fast analytical detector response function model can provide accurate estimates of spatial resolution for small-diameter PET scanners, and could be a useful tool for several applications, complementing or cross-validating other simulation methods.

Mesh:

Year:  2003        PMID: 12741496     DOI: 10.1088/0031-9155/48/8/302

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  14 in total

1.  Evaluation of the spatial dependence of the point spread function in 2D PET image reconstruction using LOR-OSEM.

Authors:  D Wiant; J A Gersh; M Bennett; J D Bourland
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

2.  Evaluation of Noise Properties in PSF-Based PET Image Reconstruction.

Authors:  Shan Tong; Adam M Alessio; Paul E Kinahan
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2009-10-24

3.  Iterative reconstruction of Fourier-rebinned PET data using sinogram blurring function estimated from point source scans.

Authors:  Michel S Tohme; Jinyi Qi
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

4.  Noise propagation in resolution modeled PET imaging and its impact on detectability.

Authors:  Arman Rahmim; Jing Tang
Journal:  Phys Med Biol       Date:  2013-09-13       Impact factor: 3.609

Review 5.  Resolution modeling in PET imaging: theory, practice, benefits, and pitfalls.

Authors:  Arman Rahmim; Jinyi Qi; Vesna Sossi
Journal:  Med Phys       Date:  2013-06       Impact factor: 4.071

6.  Sinogram Blurring Matrix Estimation From Point Sources Measurements With Rank-One Approximation for Fully 3-D PET.

Authors:  Kuang Gong; Jian Zhou; Michel Tohme; Martin Judenhofer; Yongfeng Yang; Jinyi Qi
Journal:  IEEE Trans Med Imaging       Date:  2017-06-02       Impact factor: 10.048

7.  Assessment of a three-dimensional line-of-response probability density function system matrix for PET.

Authors:  Rutao Yao; Ranjith M Ramachandra; Neeraj Mahajan; Vinay Rathod; Noel Gunasekar; Ashish Panse; Tianyu Ma; Yiqiang Jian; Jianhua Yan; Richard E Carson
Journal:  Phys Med Biol       Date:  2012-10-03       Impact factor: 3.609

8.  Online detector response calculations for high-resolution PET image reconstruction.

Authors:  Guillem Pratx; Craig Levin
Journal:  Phys Med Biol       Date:  2011-06-15       Impact factor: 3.609

9.  Application and evaluation of a measured spatially variant system model for PET image reconstruction.

Authors:  Adam M Alessio; Charles W Stearns; Shan Tong; Steven G Ross; Steve Kohlmyer; Alex Ganin; Paul E Kinahan
Journal:  IEEE Trans Med Imaging       Date:  2010-03       Impact factor: 10.048

10.  Noise and signal properties in PSF-based fully 3D PET image reconstruction: an experimental evaluation.

Authors:  S Tong; A M Alessio; P E Kinahan
Journal:  Phys Med Biol       Date:  2010-02-11       Impact factor: 3.609