Literature DB >> 16827491

Fully 3-D PET reconstruction with system matrix derived from point source measurements.

Vladimir Y Panin1, Frank Kehren, Christian Michel, Michael Casey.   

Abstract

The quality of images reconstructed by statistical iterative methods depends on an accurate model of the relationship between image space and projection space through the system matrix The elements of the system matrix for the clinical Hi-Rez scanner were derived by processing the data measured for a point source at different positions in a portion of the field of view. These measured data included axial compression and azimuthal interleaving of adjacent projections. Measured data were corrected for crystal and geometrical efficiency. Then, a whole system matrix was derived by processing the responses in projection space. Such responses included both geometrical and detection physics components of the system matrix. The response was parameterized to correct for point source location and to smooth for projection noise. The model also accounts for axial compression (span) used on the scanner. The forward projector for iterative reconstruction was constructed using the estimated response parameters. This paper extends our previous work to fully three-dimensional. Experimental data were used to compare images reconstructed by the standard iterative reconstruction software and the one modeling the response function. The results showed that the modeling of the response function improves both spatial resolution and noise properties.

Mesh:

Year:  2006        PMID: 16827491     DOI: 10.1109/tmi.2006.876171

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  131 in total

Review 1.  Improvement in PET myocardial perfusion image quality and quantification with flurpiridaz F 18.

Authors:  Daniel S Berman; Guido Germano; Piotr J Slomka
Journal:  J Nucl Cardiol       Date:  2012-02       Impact factor: 5.952

2.  Evaluation of the spatial dependence of the point spread function in 2D PET image reconstruction using LOR-OSEM.

Authors:  D Wiant; J A Gersh; M Bennett; J D Bourland
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

3.  Evaluation of Noise Properties in PSF-Based PET Image Reconstruction.

Authors:  Shan Tong; Adam M Alessio; Paul E Kinahan
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2009-10-24

4.  Iterative reconstruction of Fourier-rebinned PET data using sinogram blurring function estimated from point source scans.

Authors:  Michel S Tohme; Jinyi Qi
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

5.  Effects of point spread function-based image reconstruction on neuroreceptor binding in positron emission tomography study with [(11)C]FLB 457.

Authors:  Thonnapong Thongpraparn; Yoko Ikoma; Takahiro Shiraishi; Taiga Yamaya; Hiroshi Ito
Journal:  Radiol Phys Technol       Date:  2015-12-16

6.  Comparative analysis of iterative reconstruction algorithms with resolution recovery and time of flight modeling for 18F-FDG cardiac PET: A multi-center phantom study.

Authors:  Roberta Matheoud; Michela Lecchi; Domenico Lizio; Camilla Scabbio; Claudio Marcassa; Lucia Leva; Angelo Del Sole; Carlo Rodella; Luca Indovina; Christian Bracco; Marco Brambilla; Orazio Zoccarato
Journal:  J Nucl Cardiol       Date:  2016-01-12       Impact factor: 5.952

7.  Noise propagation in resolution modeled PET imaging and its impact on detectability.

Authors:  Arman Rahmim; Jing Tang
Journal:  Phys Med Biol       Date:  2013-09-13       Impact factor: 3.609

8.  Efficient fully 3D list-mode TOF PET image reconstruction using a factorized system matrix with an image domain resolution model.

Authors:  Jian Zhou; Jinyi Qi
Journal:  Phys Med Biol       Date:  2014-01-17       Impact factor: 3.609

9.  Applications of the line-of-response probability density function resolution model in PET list mode reconstruction.

Authors:  Y Jian; R Yao; T Mulnix; X Jin; R E Carson
Journal:  Phys Med Biol       Date:  2014-12-09       Impact factor: 3.609

10.  An assessment of the impact of incorporating time-of-flight information into clinical PET/CT imaging.

Authors:  Cristina Lois; Bjoern W Jakoby; Misty J Long; Karl F Hubner; David W Barker; Michael E Casey; Maurizio Conti; Vladimir Y Panin; Dan J Kadrmas; David W Townsend
Journal:  J Nucl Med       Date:  2010-01-15       Impact factor: 10.057

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.