Literature DB >> 21674615

QUantitative Imaging of eXtraction of oxygen and TIssue consumption (QUIXOTIC) using venular-targeted velocity-selective spin labeling.

D S Bolar1, B R Rosen, A G Sorensen, E Adalsteinsson.   

Abstract

While oxygen extraction fraction (OEF) and cerebral metabolic rate of oxygen (CMRO(2)) are fundamental parameters of brain health and function, a robust MRI-based mapping of OEF and CMRO(2) amenable to functional MRI (fMRI) has not been established. To address this issue, a novel method called QUantitative Imaging of eXtraction of Oxygen and TIssue Consumption, or QUIXOTIC, is introduced. The key innovation in QUIXOTIC is the use of velocity-selective spin labeling to isolate MR signal exclusively from postcapillary venular blood on a voxel-by-voxel basis. Measuring the T(2) of this venular-targeted blood allows calibration to venular oxygen saturation (Y(v)) via theoretical and experimental T(2) versus blood oxygen saturation relationships. Y(v) is converted to OEF, and baseline CMRO(2) is subsequently estimated from OEF and additional cerebral blood flow and hematocrit measurements. Theory behind the QUIXOTIC technique is presented, and implications of cutoff velocity (V(CUTOFF)) and outflow time parameters are discussed. Cortical gray matter values obtained with QUIXOTIC in 10 healthy volunteers are Y(v) = 0.73 ± 0.02, OEF = 0.26 ± 0.02, and CMRO(2) = 125 ± 15 μmol/100 g min. Results are compared to global measures obtained with the T(2) relaxation under spin tagging (TRUST) technique. The preliminary data presented suggest that QUIXOTIC will be useful for mapping Y(v), OEF, and CMRO(2), in both clinical and functional MRI settings.
Copyright © 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21674615      PMCID: PMC3217089          DOI: 10.1002/mrm.22946

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  39 in total

1.  Quantitative measurements of cerebral blood oxygen saturation using magnetic resonance imaging.

Authors:  H An; W Lin
Journal:  J Cereb Blood Flow Metab       Date:  2000-08       Impact factor: 6.200

2.  Evaluation of systematic quantification errors in velocity-selective arterial spin labeling of the brain.

Authors:  Guillaume Duhamel; Cédric de Bazelaire; David C Alsop
Journal:  Magn Reson Med       Date:  2003-07       Impact factor: 4.668

3.  In vivo measurement of blood oxygen saturation using magnetic resonance imaging: a direct validation of the blood oxygen level-dependent concept in functional brain imaging.

Authors:  E M Haacke; S Lai; J R Reichenbach; K Kuppusamy; F G Hoogenraad; H Takeichi; W Lin
Journal:  Hum Brain Mapp       Date:  1997       Impact factor: 5.038

4.  MR susceptometry for measuring global brain oxygen extraction.

Authors:  María A Fernández-Seara; Aranee Techawiboonwong; John A Detre; Felix W Wehrli
Journal:  Magn Reson Med       Date:  2006-05       Impact factor: 4.668

5.  1991 I.I. Rabi Award. Estimating oxygen saturation of blood in vivo with MR imaging at 1.5 T.

Authors:  G A Wright; B S Hu; A Macovski
Journal:  J Magn Reson Imaging       Date:  1991 May-Jun       Impact factor: 4.813

6.  Quantification of cerebral blood flow and oxygen metabolism with 3-dimensional PET and 15O: validation by comparison with 2-dimensional PET.

Authors:  Masanobu Ibaraki; Shuichi Miura; Eku Shimosegawa; Shigeki Sugawara; Tetsuro Mizuta; Akihiro Ishikawa; Masaharu Amano
Journal:  J Nucl Med       Date:  2007-12-12       Impact factor: 10.057

7.  Coronary angiography with magnetization-prepared T2 contrast.

Authors:  J H Brittain; B S Hu; G A Wright; C H Meyer; A Macovski; D G Nishimura
Journal:  Magn Reson Med       Date:  1995-05       Impact factor: 4.668

8.  QUantitative Imaging of eXtraction of oxygen and TIssue consumption (QUIXOTIC) using venular-targeted velocity-selective spin labeling.

Authors:  D S Bolar; B R Rosen; A G Sorensen; E Adalsteinsson
Journal:  Magn Reson Med       Date:  2011-06-14       Impact factor: 4.668

9.  In vivo measurement of changes in venous blood-oxygenation with high resolution functional MRI at 0.95 tesla by measuring changes in susceptibility and velocity.

Authors:  F G Hoogenraad; J R Reichenbach; E M Haacke; S Lai; K Kuppusamy; M Sprenger
Journal:  Magn Reson Med       Date:  1998-01       Impact factor: 4.668

10.  Cerebral oxygen metabolism after aneurysmal subarachnoid hemorrhage.

Authors:  D A Carpenter; R L Grubb; L W Tempel; W J Powers
Journal:  J Cereb Blood Flow Metab       Date:  1991-09       Impact factor: 6.200

View more
  77 in total

1.  Venous oxygenation mapping using velocity-selective excitation and arterial nulling.

Authors:  Jia Guo; Eric C Wong
Journal:  Magn Reson Med       Date:  2012-01-31       Impact factor: 4.668

2.  Cerebral oxygen metabolism in neonates with congenital heart disease quantified by MRI and optics.

Authors:  Varsha Jain; Erin M Buckley; Daniel J Licht; Jennifer M Lynch; Peter J Schwab; Maryam Y Naim; Natasha A Lavin; Susan C Nicolson; Lisa M Montenegro; Arjun G Yodh; Felix W Wehrli
Journal:  J Cereb Blood Flow Metab       Date:  2013-12-11       Impact factor: 6.200

Review 3.  The physics of functional magnetic resonance imaging (fMRI).

Authors:  Richard B Buxton
Journal:  Rep Prog Phys       Date:  2013-09-04

4.  Mitigation of partial volume effects in susceptibility-based oxygenation measurements by joint utilization of magnitude and phase (JUMP).

Authors:  Patrick McDaniel; Berkin Bilgic; Audrey P Fan; Jeffrey N Stout; Elfar Adalsteinsson
Journal:  Magn Reson Med       Date:  2016-04-05       Impact factor: 4.668

Review 5.  Non-invasive assessment of neonatal brain oxygen metabolism: A review of newly available techniques.

Authors:  Peiying Liu; Lina F Chalak; Hanzhang Lu
Journal:  Early Hum Dev       Date:  2014-07-11       Impact factor: 2.079

6.  QUantitative Imaging of eXtraction of oxygen and TIssue consumption (QUIXOTIC) using venular-targeted velocity-selective spin labeling.

Authors:  D S Bolar; B R Rosen; A G Sorensen; E Adalsteinsson
Journal:  Magn Reson Med       Date:  2011-06-14       Impact factor: 4.668

7.  Correction and optimization of a T2-based approach to map blood oxygenation in small cerebral veins.

Authors:  Lisa C Krishnamurthy; Deng Mao; Kevin S King; Hanzhang Lu
Journal:  Magn Reson Med       Date:  2015-04-04       Impact factor: 4.668

8.  Multisite evaluations of a T2 -relaxation-under-spin-tagging (TRUST) MRI technique to measure brain oxygenation.

Authors:  Peiying Liu; Ivan Dimitrov; Trevor Andrews; David E Crane; Jacinda K Dariotis; John Desmond; Julie Dumas; Guillaume Gilbert; Anand Kumar; Bradley J Maclntosh; Alan Tucholka; Shaolin Yang; Guanghua Xiao; Hanzhang Lu
Journal:  Magn Reson Med       Date:  2015-04-04       Impact factor: 4.668

Review 9.  Imaging brain oxygenation with MRI using blood oxygenation approaches: methods, validation, and clinical applications.

Authors:  T Christen; D S Bolar; G Zaharchuk
Journal:  AJNR Am J Neuroradiol       Date:  2012-08-02       Impact factor: 3.825

10.  Quantification of whole-brain oxygenation extraction fraction and cerebral metabolic rate of oxygen consumption in adults with sickle cell anemia using individual T2 -based oxygenation calibrations.

Authors:  Wenbo Li; Xiang Xu; Peiying Liu; John J Strouse; James F Casella; Hanzhang Lu; Peter C M van Zijl; Qin Qin
Journal:  Magn Reson Med       Date:  2019-09-04       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.