Quantification of cerebral blood flow and oxygen metabolism with 3-dimensional PET and 15O: validation by comparison with 2-dimensional PET.

Masanobu Ibaraki1, Shuichi Miura, Eku Shimosegawa, Shigeki Sugawara, Tetsuro Mizuta, Akihiro Ishikawa, Masaharu Amano.   

Abstract

UNLABELLED: Quantitative PET with (15)O provides absolute values for cerebral blood flow (CBF), cerebral blood volume (CBV), cerebral metabolic rate of oxygen (CMRO(2)), and oxygen extraction fraction (OEF), which are used for assessment of brain pathophysiology. Absolute quantification relies on physically accurate measurement, which, thus far, has been achieved by 2-dimensional PET (2D PET), the current gold standard for measurement of CBF and oxygen metabolism. We investigated whether quantitative (15)O study with 3-dimensional PET (3D PET) shows the same degree of accuracy as 2D PET.
METHODS: 2D PET and 3D PET measurements were obtained on the same day on 8 healthy men (age, 21-24 y). 2D PET was performed using a PET scanner with bismuth germanate (BGO) detectors and a 150-mm axial field of view (FOV). For 3D PET, a 3D-only tomograph with gadolinium oxyorthosilicate (GSO) detectors and a 156-mm axial FOV was used. A hybrid scatter-correction method based on acquisition in the dual-energy window (hybrid dual-energy window [HDE] method) was applied in the 3D PET study. Each PET study included 3 sequential PET scans for C(15)O, (15)O(2), and H(2)(15)O (3-step method). The inhaled (or injected) dose for 3D PET was approximately one fourth of that for 2D PET.
RESULTS: In the 2D PET study, average gray matter values (mean +/- SD) of CBF, CBV, CMRO(2), and OEF were 53 +/- 12 (mL/100 mL/min), 3.6 +/- 0.3 (mL/100 mL), 3.5 +/- 0.5 (mL/100 mL/min), and 0.35 +/- 0.06, respectively. In the 3D PET study, scatter correction strongly affected the results. Without scatter correction, average values were 44 +/- 6 (mL/100 mL/min), 5.2 +/- 0.6 (mL/100 mL), 3.3 +/- 0.4 (mL/100 mL/min), and 0.39 +/- 0.05, respectively. With the exception of OEF, values differed between 2D PET and 3D PET. However, average gray matter values of scatter-corrected 3D PET were comparable to those of 2D PET: 55 +/- 11 (mL/100 mL/min), 3.7 +/- 0.5 (mL/100 mL), 3.8 +/- 0.7 (mL/100 mL/min), and 0.36 +/- 0.06, respectively. Even though the 2 PET scanners with different crystal materials, data acquisition systems, spatial resolution, and attenuation-correction methods were used, the agreement of the results between 2D PET and scatter-corrected 3D PET was excellent.
CONCLUSION: Scatter coincidence is a problem in 3D PET for quantitative (15)O study. The combination of both the present PET/CT device and the HDE scatter correction permits quantitative 3D PET with the same degree of accuracy as 2D PET and with a lower radiation dose. The present scanner is also applicable to conventional steady-state (15)O gas inhalation if inhaled doses are adjusted appropriately.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18077532     DOI: 10.2967/jnumed.107.044008

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  48 in total

1.  MRI estimation of global brain oxygen consumption rate.

Authors:  Varsha Jain; Michael C Langham; Felix W Wehrli
Journal:  J Cereb Blood Flow Metab       Date:  2010-04-21       Impact factor: 6.200

2.  Temporal dynamics and spatial specificity of arterial and venous blood volume changes during visual stimulation: implication for BOLD quantification.

Authors:  Tae Kim; Seong-Gi Kim
Journal:  J Cereb Blood Flow Metab       Date:  2010-12-22       Impact factor: 6.200

3.  Model of the transient neurovascular response based on prompt arterial dilation.

Authors:  Jung Hwan Kim; Reswanul Khan; Jeffrey K Thompson; David Ress
Journal:  J Cereb Blood Flow Metab       Date:  2013-06-12       Impact factor: 6.200

Review 4.  Susceptibility-based time-resolved whole-organ and regional tissue oximetry.

Authors:  Felix W Wehrli; Audrey P Fan; Zachary B Rodgers; Erin K Englund; Michael C Langham
Journal:  NMR Biomed       Date:  2016-02-26       Impact factor: 4.044

5.  QUantitative Imaging of eXtraction of oxygen and TIssue consumption (QUIXOTIC) using venular-targeted velocity-selective spin labeling.

Authors:  D S Bolar; B R Rosen; A G Sorensen; E Adalsteinsson
Journal:  Magn Reson Med       Date:  2011-06-14       Impact factor: 4.668

6.  Direct (17)O MRI with partial volume correction: first experiences in a glioblastoma patient.

Authors:  Stefan H Hoffmann; Alexander Radbruch; Michael Bock; Wolfhard Semmler; Armin M Nagel
Journal:  MAGMA       Date:  2014-04-01       Impact factor: 2.310

Review 7.  Time-resolved MRI oximetry for quantifying CMRO(2) and vascular reactivity.

Authors:  Felix W Wehrli; Zachary B Rodgers; Varsha Jain; Michael C Langham; Cheng Li; Daniel J Licht; Jeremy Magland
Journal:  Acad Radiol       Date:  2014-02       Impact factor: 3.173

8.  Paradoxical reduction of cerebral blood flow after acetazolamide loading: a hemodynamic and metabolic study with (15)O PET.

Authors:  Tadashi Watabe; Eku Shimosegawa; Hiroki Kato; Kayako Isohashi; Mana Ishibashi; Mitsuaki Tatsumi; Kazuo Kitagawa; Toshiyuki Fujinaka; Toshiki Yoshimine; Jun Hatazawa
Journal:  Neurosci Bull       Date:  2014-08-06       Impact factor: 5.203

9.  New insights into central roles of cerebral oxygen metabolism in the resting and stimulus-evoked brain.

Authors:  Xiao-Hong Zhu; Nanyin Zhang; Yi Zhang; Kâmil Uğurbil; Wei Chen
Journal:  J Cereb Blood Flow Metab       Date:  2008-09-10       Impact factor: 6.200

10.  Noninvasive quantification of whole-brain cerebral metabolic rate of oxygen (CMRO2) by MRI.

Authors:  Feng Xu; Yulin Ge; Hanzhang Lu
Journal:  Magn Reson Med       Date:  2009-07       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.