Literature DB >> 30806599

Evaluation of a Flexible 12-Channel Screen-printed Pediatric MRI Coil.

Simone Angela Winkler1, Joseph Corea1, Balthazar Lechêne1, Kendall O'Brien1, John Ross Bonanni1, Akshay Chaudhari1, Marcus Alley1, Valentina Taviani1, Thomas Grafendorfer1, Fraser Robb1, Greig Scott1, John Pauly1, Michael Lustig1, Ana Claudia Arias1, Shreyas Vasanawala1.   

Abstract

Background Screen-printed MRI coil technology may reduce the need for bulky and heavy housing of coil electronics and may provide a better fit to patient anatomy to improve coil performance. Purpose To assess the performance and caregiver and clinician acceptance of a pediatric-sized screen-printed flexible MRI coil array as compared with conventional coil technology. Materials and Methods A pediatric-sized 12-channel coil array was designed by using a screen-printing process. Element coupling and phantom signal-to-noise ratio (SNR) were assessed. Subjects were scanned by using the pediatric printed array between September and November 2017; results were compared with three age- and sex-matched historical control subjects by using a commercial 32-channel cardiac array at 3 T. Caregiver acceptance was assessed by asking nurses, technologists, anesthesiologists, and subjects or parents to rate their coil preference. Diagnostic quality of the images was evaluated by using a Likert scale (5 = high image quality, 1 = nondiagnostic). Image SNR was evaluated and compared. Results Twenty study participants were evaluated with the screen-printed coil (age range, 2 days to 12 years; 11 male and nine female subjects). Loaded pediatric phantom testing yielded similar noise covariance matrices and only slightly degraded SNR for the printed coil as compared with the commercial coil. The caregiver acceptance survey yielded a mean score of 4.1 ± 0.6 (scale: 1, preferred the commercial coil; 5, preferred the printed coil). Diagnostic quality score was 4.5 ± 0.6. Mean image SNR was 54 ± 49 (paraspinal muscle), 78 ± 51 (abdominal wall muscle), and 59 ± 35 (psoas) for the printed coil, as compared with 64 ± 55, 65 ± 48, and 57 ± 43, respectively, for the commercial coil; these SNR differences were not statistically significant (P = .26). Conclusion A flexible screen-printed pediatric MRI receive coil yields adequate signal-to-noise ratio in phantoms and pediatric study participants, with similar image quality but higher preference by subjects and their caregivers when compared with a conventional MRI coil. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Lamb in this issue.

Entities:  

Mesh:

Year:  2019        PMID: 30806599      PMCID: PMC6444619          DOI: 10.1148/radiol.2019181883

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  14 in total

1.  The NMR phased array.

Authors:  P B Roemer; W A Edelstein; C E Hayes; S P Souza; O M Mueller
Journal:  Magn Reson Med       Date:  1990-11       Impact factor: 4.668

2.  Clinical performance of contrast enhanced abdominal pediatric MRI with fast combined parallel imaging compressed sensing reconstruction.

Authors:  Tao Zhang; Shilpy Chowdhury; Michael Lustig; Richard A Barth; Marcus T Alley; Thomas Grafendorfer; Paul D Calderon; Fraser J L Robb; John M Pauly; Shreyas S Vasanawala
Journal:  J Magn Reson Imaging       Date:  2013-10-11       Impact factor: 4.813

3.  An MRI receiver coil produced by inkjet printing directly on to a flexible substrate.

Authors:  Dario Mager; Andreas Peter; Laura Del Tin; Elmar Fischer; Patrick J Smith; Jürgen Hennig; Jan G Korvink
Journal:  IEEE Trans Med Imaging       Date:  2010-02       Impact factor: 10.048

Review 4.  Paediatric MRI under sedation: is it necessary? What is the evidence for the alternatives?

Authors:  Andrea D Edwards; Owen J Arthurs
Journal:  Pediatr Radiol       Date:  2011-06-16

5.  Size-adaptable 13-channel receive array for brain MRI in human neonates at 3 T.

Authors:  Nibardo Lopez Rios; Alexandru Foias; Gregory Lodygensky; Mathieu Dehaes; Julien Cohen-Adad
Journal:  NMR Biomed       Date:  2018-06-21       Impact factor: 4.044

Review 6.  Advances in pediatric body MRI.

Authors:  Shreyas S Vasanawala; Michael Lustig
Journal:  Pediatr Radiol       Date:  2011-08-17

7.  Materials and methods for higher performance screen-printed flexible MRI receive coils.

Authors:  Joseph R Corea; P Balthazar Lechene; Michael Lustig; Ana C Arias
Journal:  Magn Reson Med       Date:  2016-09-09       Impact factor: 4.668

8.  A semiflexible 64-channel receive-only phased array for pediatric body MRI at 3T.

Authors:  Tao Zhang; Thomas Grafendorfer; Joseph Y Cheng; Peigang Ning; Bob Rainey; Mark Giancola; Sarah Ortman; Fraser J Robb; Paul D Calderon; Brian A Hargreaves; Michael Lustig; Greig C Scott; John M Pauly; Shreyas S Vasanawala
Journal:  Magn Reson Med       Date:  2015-09-29       Impact factor: 4.668

9.  ESPIRiT--an eigenvalue approach to autocalibrating parallel MRI: where SENSE meets GRAPPA.

Authors:  Martin Uecker; Peng Lai; Mark J Murphy; Patrick Virtue; Michael Elad; John M Pauly; Shreyas S Vasanawala; Michael Lustig
Journal:  Magn Reson Med       Date:  2014-03       Impact factor: 4.668

10.  Screen-printed flexible MRI receive coils.

Authors:  Joseph R Corea; Anita M Flynn; Balthazar Lechêne; Greig Scott; Galen D Reed; Peter J Shin; Michael Lustig; Ana C Arias
Journal:  Nat Commun       Date:  2016-03-10       Impact factor: 14.919

View more
  9 in total

Review 1.  Fetal Echoplanar Imaging: Promises and Challenges.

Authors:  Onur Afacan; Judy A Estroff; Edward Yang; Carol E Barnewolt; Susan A Connolly; Richard B Parad; Robert V Mulkern; Simon K Warfield; Ali Gholipour
Journal:  Top Magn Reson Imaging       Date:  2019-10

Review 2.  Compact pediatric cardiac magnetic resonance imaging protocols.

Authors:  Evan J Zucker
Journal:  Pediatr Radiol       Date:  2022-07-12

Review 3.  Pediatric magnetic resonance imaging: faster is better.

Authors:  Sebastian Gallo-Bernal; M Alejandra Bedoya; Michael S Gee; Camilo Jaimes
Journal:  Pediatr Radiol       Date:  2022-10-20

4.  Characterization of a Low-Profile, Flexible, and Acoustically Transparent Receive-Only MRI Coil Array for High Sensitivity MR-Guided Focused Ultrasound.

Authors:  Isabelle Saniour; Fraser J L Robb; Victor Taracila; Vishwas Mishra; Jana Vincent; Henning U Voss; Michael G Kaplitt; J Levi Chazen; Simone Angela Winkler
Journal:  IEEE Access       Date:  2022-02-25       Impact factor: 3.476

5.  Iterative motion-compensation reconstruction ultra-short TE (iMoCo UTE) for high-resolution free-breathing pulmonary MRI.

Authors:  Xucheng Zhu; Marilynn Chan; Michael Lustig; Kevin M Johnson; Peder E Z Larson
Journal:  Magn Reson Med       Date:  2019-09-30       Impact factor: 4.668

Review 6.  Safety challenges related to the use of sedation and general anesthesia in pediatric patients undergoing magnetic resonance imaging examinations.

Authors:  Maddy Artunduaga; C Amber Liu; Cara E Morin; Suraj D Serai; Unni Udayasankar; Mary-Louise C Greer; Michael S Gee
Journal:  Pediatr Radiol       Date:  2021-04-16

Review 7.  Educational fMRI: From the Lab to the Classroom.

Authors:  Mohamed L Seghier; Mohamed A Fahim; Claudine Habak
Journal:  Front Psychol       Date:  2019-12-06

8.  Application of Highly Flexible Adaptive Image Receive Coil for Lung MR Imaging Using Zero TE Sequence: Comparison with Conventional Anterior Array Coil.

Authors:  Kyungsoo Bae; Kyung Nyeo Jeon; Moon Jung Hwang; Yunsub Jung; Joonsung Lee
Journal:  Diagnostics (Basel)       Date:  2022-01-08

Review 9.  Rapid Knee MRI Acquisition and Analysis Techniques for Imaging Osteoarthritis.

Authors:  Akshay S Chaudhari; Feliks Kogan; Valentina Pedoia; Sharmila Majumdar; Garry E Gold; Brian A Hargreaves
Journal:  J Magn Reson Imaging       Date:  2019-11-21       Impact factor: 4.813

  9 in total