Literature DB >> 26009490

Signal-to-noise ratio and parallel imaging performance of commercially available phased array coils in 3.0 T brain magnetic resonance imaging.

Tsukasa Yoshida1, Kensei Shirata, Atsushi Urikura, Michitoshi Ito, Yoshihiro Nakaya.   

Abstract

The signal-to-noise ratio (SNR) and parallel imaging (PI) performance of two commercial phased-array coils (PACs) were examined in magnetic resonance imaging (MRI) of the brain. All measurements were performed on a 3.0 T MRI instrument. The SNR and PI performance were evaluated with 32-channel and 15-channel PACs. A gradient echo sequence was used for obtaining images of a phantom. SNR and geometry factor (g-factor) maps were calculated from two images with identical parameters. Horizontal and vertical profiles were taken through the SNR maps in the axial plane. The average g-factor was measured in a circular region of interest in the g-factor maps for the axial plane. The SNR map of the 32-channel coil showed a higher SNR than that of the 15-channel coil at the phantom's posterior and lateral surfaces. The SNR profiles for the 32-channel coil also showed a 1.3-fold increase at the phantom's center. The average g-factor of the 32-channel coil was lower than that of the 15-channel coil at the same acceleration factor. These results indicate that the 32-channel coil can provide a higher spatial resolution and/or a faster imaging speed. Horizontal and vertical profiles are useful for evaluation of the performance of commercially available PACs.

Mesh:

Year:  2015        PMID: 26009490     DOI: 10.1007/s12194-015-0321-6

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  25 in total

1.  A four-element phased array coil for high resolution and parallel MR imaging of the knee.

Authors:  Wingchi E Kwok; Jianhui Zhong; Zhigang You; Gwysuk Seo; Saara M S Totterman
Journal:  Magn Reson Imaging       Date:  2003-11       Impact factor: 2.546

2.  Measurement of signal-to-noise ratios in MR images: influence of multichannel coils, parallel imaging, and reconstruction filters.

Authors:  Olaf Dietrich; José G Raya; Scott B Reeder; Maximilian F Reiser; Stefan O Schoenberg
Journal:  J Magn Reson Imaging       Date:  2007-08       Impact factor: 4.813

3.  [Signal-to-noise ratio measurement in parallel MRI with subtraction mapping and consecutive methods].

Authors:  Hiroshi Imai; Tosiaki Miyati; Akio Ogura; Tsukasa Doi; Toshio Tsuchihashi; Yoshio Machida; Masato Kobayashi; Kouzou Shimizu; Yoshihiro Kitou
Journal:  Nihon Hoshasen Gijutsu Gakkai Zasshi       Date:  2008-08-20

4.  Noise in MRI.

Authors:  A Macovski
Journal:  Magn Reson Med       Date:  1996-09       Impact factor: 4.668

5.  High resolution MR imaging of the bilateral hips with dual phased-array coil.

Authors:  M Niitsu; H Mishima; S Miyakawa; Y Itai
Journal:  J Magn Reson Imaging       Date:  1996 Nov-Dec       Impact factor: 4.813

6.  Measuring signal-to-noise ratios in MR imaging.

Authors:  L Kaufman; D M Kramer; L E Crooks; D A Ortendahl
Journal:  Radiology       Date:  1989-10       Impact factor: 11.105

7.  Quality assurance methods and phantoms for magnetic resonance imaging: report of AAPM nuclear magnetic resonance Task Group No. 1.

Authors:  R R Price; L Axel; T Morgan; R Newman; W Perman; N Schneiders; M Selikson; M Wood; S R Thomas
Journal:  Med Phys       Date:  1990 Mar-Apr       Impact factor: 4.071

8.  Phased array RF coils for high-resolution MRI of the inner ear and brain stem.

Authors:  P Schmalbrock; J Pruski; L Sun; A Rao; J W Monroe
Journal:  J Comput Assist Tomogr       Date:  1995 Jan-Feb       Impact factor: 1.826

9.  Pelvic imaging with phased-array coils: quantitative assessment of signal-to-noise ratio improvement.

Authors:  C E Hayes; M J Dietz; B F King; R L Ehman
Journal:  J Magn Reson Imaging       Date:  1992 May-Jun       Impact factor: 4.813

10.  MR imaging of the abdomen with a phased-array multicoil: prospective clinical evaluation.

Authors:  N G Campeau; C D Johnson; J P Felmlee; J N Rydberg; R K Butts; R L Ehman; S J Riederer
Journal:  Radiology       Date:  1995-06       Impact factor: 11.105

View more
  1 in total

1.  Image quality assessment of single-shot turbo spin echo diffusion-weighted imaging with parallel imaging technique: a phantom study.

Authors:  Tsukasa Yoshida; Atsushi Urikura; Kensei Shirata; Yoshihiro Nakaya; Shingo Terashima; Yoichiro Hosokawa
Journal:  Br J Radiol       Date:  2016-07-25       Impact factor: 3.039

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.