Literature DB >> 21617744

ScanSim: A tool for simulating optical-CT imaging.

Mark Oldham1.   

Abstract

A software tool has been developed that can simulate image formation in a variety of optical-CT scanning configurations. The formalism of the simulation is introduced, including two main modes: a diverging point source mode, and a converging broad beam mode. Preliminary results are presented for scanning Presage dosimeters in both modes and immersed in refractive media of widely varying refractive index (RI), including air, water, and a fully matched medium. Pronounced differences in the edge artifacts and accuracy of reconstructed coefficients is observed. The ScanSim software is shown to be a useful tool to investigate and quantify many aspects of optical-CT image formation, including reducing dependence on matching fluids.

Entities:  

Year:  2010        PMID: 21617744      PMCID: PMC3100580          DOI: 10.1088/1742-6596/250/1/012064

Source DB:  PubMed          Journal:  J Phys Conf Ser        ISSN: 1742-6588


  9 in total

1.  A CCD-based optical CT scanner for high-resolution 3D imaging of radiation dose distributions: equipment specifications, optical simulations and preliminary results.

Authors:  S J Doran; K K Koerkamp; M A Bero; P Jenneson; E J Morton; W B Gilboy
Journal:  Phys Med Biol       Date:  2001-12       Impact factor: 3.609

2.  Cone beam optical computed tomography for gel dosimetry I: scanner characterization.

Authors:  Tim Olding; Oliver Holmes; L John Schreiner
Journal:  Phys Med Biol       Date:  2010-04-22       Impact factor: 3.609

3.  Performance of a commercial optical CT scanner and polymer gel dosimeters for 3-D dose verification.

Authors:  Y Xu; Cheng-Shie Wuu; Marek J Maryanski
Journal:  Med Phys       Date:  2004-11       Impact factor: 4.071

4.  3D dosimetry by optical-CT scanning.

Authors:  Mark Oldham
Journal:  J Phys Conf Ser       Date:  2006

5.  A comprehensive evaluation of the PRESAGE/optical-CT 3D dosimetry system.

Authors:  H S Sakhalkar; J Adamovics; G Ibbott; M Oldham
Journal:  Med Phys       Date:  2009-01       Impact factor: 4.071

6.  Initial evaluation of commercial optical CT-based 3D gel dosimeter.

Authors:  K T S Islam; James F Dempsey; Manisha K Ranade; Marek J Maryanski; Daniel A Low
Journal:  Med Phys       Date:  2003-08       Impact factor: 4.071

7.  Radiation dose distributions in three dimensions from tomographic optical density scanning of polymer gels: I. Development of an optical scanner.

Authors:  J C Gore; M Ranade; M J Maryañski; R J Schulz
Journal:  Phys Med Biol       Date:  1996-12       Impact factor: 3.609

Review 8.  Polymer gel dosimetry.

Authors:  C Baldock; Y De Deene; S Doran; G Ibbott; A Jirasek; M Lepage; K B McAuley; M Oldham; L J Schreiner
Journal:  Phys Med Biol       Date:  2010-02-11       Impact factor: 3.609

9.  Toward acquiring comprehensive radiosurgery field commissioning data using the PRESAGE/optical-CT 3D dosimetry system.

Authors:  Corey Clift; Andrew Thomas; John Adamovics; Zheng Chang; Indra Das; Mark Oldham
Journal:  Phys Med Biol       Date:  2010-02-04       Impact factor: 3.609

  9 in total
  4 in total

1.  How effective can optical-CT 3D dosimetry be without refractive fluid matching?

Authors:  L Rankine
Journal:  J Phys Conf Ser       Date:  2013

2.  Investigations into the feasibility of optical-CT 3D dosimetry with minimal use of refractively matched fluids.

Authors:  Kelsey Chisholm; Devin Miles; Leith Rankine; Mark Oldham
Journal:  Med Phys       Date:  2015-05       Impact factor: 4.071

3.  On the feasibility of optical-CT imaging in media of different refractive index.

Authors:  Leith Rankine; Mark Oldham
Journal:  Med Phys       Date:  2013-05       Impact factor: 4.071

4.  Towards comprehensive characterization of Cs-137 Seeds using PRESAGE® dosimetry with optical tomography.

Authors:  J Adamson; Y Yang; L Rankine; J Newton; J Adamovics; O Craciunescu; M Oldham
Journal:  J Phys Conf Ser       Date:  2013
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.