Literature DB >> 20413828

Cone beam optical computed tomography for gel dosimetry I: scanner characterization.

Tim Olding1, Oliver Holmes, L John Schreiner.   

Abstract

The ongoing development of easily accessible, fast optical readout tools promises to remove one of the barriers to acceptance of gel dosimetry as a viable tool in cancer clinics. This paper describes the characterization of a number of basic properties of the Vista cone beam CCD-based optical scanner, which can obtain high resolution reconstructed data in less than 20 min total imaging and reconstruction time. The suitability of a filtered back projection cone beam reconstruction algorithm is established for optically absorbing dosimeters using this scanner configuration. The system was then shown to be capable of imaging an optically absorbing media-filled 1 L polyethylene terephthalate (PETE) jar dosimeter to a reconstructed voxel resolution of 0.5 x 0.5 x 0.5 mm(3). At this resolution, more than 60% of the imaged volume in the dosimeter exhibits minimal spatial distortion, a measurement accuracy of 3-4% and the mean to standard deviation signal-to-noise ratio greater than 100 over an optical absorption range of 0.06-0.18 cm(-1). An inter-day scan precision of 1% was demonstrated near the upper end of this range. Absorption measurements show evidence of stray light perturbation causing artifacts in the data, which if better managed would improve the accuracy of optical readout. Cone beam optical attenuation measurements of scattering dosimeters, on the other hand, are nonlinearly affected by angled scatter stray light. Scatter perturbation leads to significant cupping artifacts and other inaccuracies that greatly limit the readout of scattering polymer gel dosimeters with cone beam optical CT.

Entities:  

Mesh:

Year:  2010        PMID: 20413828     DOI: 10.1088/0031-9155/55/10/003

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  16 in total

1.  Commissioning and benchmarking a 3D dosimetry system for clinical use.

Authors:  Andrew Thomas; Joseph Newton; John Adamovics; Mark Oldham
Journal:  Med Phys       Date:  2011-08       Impact factor: 4.071

2.  Optical cone beam tomography of Cherenkov-mediated signals for fast 3D dosimetry of x-ray photon beams in water.

Authors:  Adam K Glaser; Jacqueline M Andreozzi; Rongxiao Zhang; Brian W Pogue; David J Gladstone
Journal:  Med Phys       Date:  2015-07       Impact factor: 4.071

Review 3.  Optical and x-ray technology synergies enabling diagnostic and therapeutic applications in medicine.

Authors:  Brian W Pogue; Brian C Wilson
Journal:  J Biomed Opt       Date:  2018-10       Impact factor: 3.170

4.  On the feasibility of optical-CT imaging in media of different refractive index.

Authors:  Leith Rankine; Mark Oldham
Journal:  Med Phys       Date:  2013-05       Impact factor: 4.071

5.  Video-rate optical dosimetry and dynamic visualization of IMRT and VMAT treatment plans in water using Cherenkov radiation.

Authors:  Adam K Glaser; Jacqueline M Andreozzi; Scott C Davis; Rongxiao Zhang; Brian W Pogue; Colleen J Fox; David J Gladstone
Journal:  Med Phys       Date:  2014-06       Impact factor: 4.071

6.  Optical scanner for 3D radiotherapy polymer gel dosimetry.

Authors:  Piotr Sobotka; Marek Kozicki; Piotr Maras; Ł Boniecki; K Kacperski; A W Domański
Journal:  Acta Phys Pol A       Date:  2012-11       Impact factor: 0.577

7.  A method to correct for spectral artifacts in optical-CT dosimetry.

Authors:  Andrew Thomas; Michael Pierquet; Kevin Jordan; Mark Oldham
Journal:  Phys Med Biol       Date:  2011-05-13       Impact factor: 3.609

8.  ScanSim: A tool for simulating optical-CT imaging.

Authors:  Mark Oldham
Journal:  J Phys Conf Ser       Date:  2010

9.  Optical and NMR dose response of N-isopropylacrylamide normoxic polymer gel for radiation therapy dosimetry.

Authors:  Asghar Mesbahi; Vahid Jafarzadeh; Nahideh Gharehaghaji
Journal:  Rep Pract Oncol Radiother       Date:  2012-04-17

10.  Empirical quenching correction in radiochromic silicone-based three-dimensional dosimetry of spot-scanning proton therapy.

Authors:  Lia Barbosa Valdetaro; Ellen Marie Høye; Peter Sandegaard Skyt; Jørgen Breede Baltzer Petersen; Peter Balling; Ludvig Paul Muren
Journal:  Phys Imaging Radiat Oncol       Date:  2021-04-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.