Literature DB >> 24454520

How effective can optical-CT 3D dosimetry be without refractive fluid matching?

L Rankine1.   

Abstract

Achieving accurate optical CT 3D dosimetry without the use of viscous refractive index (RI) matching fluids would greatly increase convenience. Software has been developed to simulate optical CT 3D dosimetry for a range of scanning configurations including parallel-beam, point and converging light sources. For each configuration the efficacy of 3 refractive media were investigated: air, water, and a fluid closely matched to Presage (RI = 1.00, 1.33 and 1.49 respectively). The results revealed that the useable radius of the dosimeter (i.e. where data was within 2% of truth) reduced to 68% for water-matching, and 31% for dry-scanning in air. Point source incident ray geometry produced slightly more favourable results, although variation between the three geometries was relatively small. The required detector size however, increased by a factor six for dry-scanning, introducing cost penalties. For applications where dose information is not required in the periphery, some dry and low-viscous matching configurations may be feasible.

Entities:  

Year:  2013        PMID: 24454520      PMCID: PMC3894113          DOI: 10.1088/1742-6596/444/1/012065

Source DB:  PubMed          Journal:  J Phys Conf Ser        ISSN: 1742-6588


  7 in total

1.  A CCD-based optical CT scanner for high-resolution 3D imaging of radiation dose distributions: equipment specifications, optical simulations and preliminary results.

Authors:  S J Doran; K K Koerkamp; M A Bero; P Jenneson; E J Morton; W B Gilboy
Journal:  Phys Med Biol       Date:  2001-12       Impact factor: 3.609

2.  Eliminating the need for refractive index matching in optical CT scanners for radiotherapy dosimetry: I. Concept and simulations.

Authors:  Simon J Doran; Dylan N B Yatigammana
Journal:  Phys Med Biol       Date:  2012-01-12       Impact factor: 3.609

3.  A new optical-CT apparatus for 3-D radiotherapy dosimetry: is free space scanning feasible?

Authors:  Antonios E Papadakis; Giannis Zacharakis; Thomas G Maris; Jorge Ripoll; John Damilakis
Journal:  IEEE Trans Med Imaging       Date:  2010-03-18       Impact factor: 10.048

4.  Initial investigation of a novel light-scattering gel phantom for evaluation of optical CT scanners for radiotherapy gel dosimetry.

Authors:  Stephen Bosi; Pourandokht Naseri; Alicia Puran; Justin Davies; Clive Baldock
Journal:  Phys Med Biol       Date:  2007-05-01       Impact factor: 3.609

5.  Radiation dose distributions in three dimensions from tomographic optical density scanning of polymer gels: I. Development of an optical scanner.

Authors:  J C Gore; M Ranade; M J Maryañski; R J Schulz
Journal:  Phys Med Biol       Date:  1996-12       Impact factor: 3.609

6.  ScanSim: A tool for simulating optical-CT imaging.

Authors:  Mark Oldham
Journal:  J Phys Conf Ser       Date:  2010

Review 7.  Polymer gel dosimetry.

Authors:  C Baldock; Y De Deene; S Doran; G Ibbott; A Jirasek; M Lepage; K B McAuley; M Oldham; L J Schreiner
Journal:  Phys Med Biol       Date:  2010-02-11       Impact factor: 3.609

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.