Literature DB >> 21612317

Stability changes of miniscrew implants over time.

Derid S Ure1, Donald R Oliver, Ki Beom Kim, Ana Cláudia Melo, Peter H Buschang.   

Abstract

PURPOSE: To quantify in vivo changes in miniscrew implant (MSI) stability over time using resonance frequency analysis, and to determine if pilot holes and placement sites affect changes in MSI stability.
MATERIALS AND METHODS: Twenty-two self-tapping MSIs (1.6 mm wide and 9 mm long) were placed in the maxillae of 2 adult beagle dogs (20 months old). The Osstell Mentor was used to measure the implant stability quotient (ISQ) weekly for 8 weeks. A split-mouth design was used to evaluate the effects of 1.1-mm wide, 3-mm deep pilot holes.
RESULTS: The MSIs that failed showed significantly (P < .05) greater decreases in ISQ values during the first 3 weeks than the MSIs that remained stable. All of the MSIs that failed (41%) had been placed in nonkeratinized tissue. MSIs that remained stable throughout the study also showed significant decreases in ISQ values during the first 3 weeks, followed by increases during the fourth and fifth weeks. Changes in ISQ values of MSIs inserted into bone with and without pilot holes were comparable (P > .05).
CONCLUSION: Stability of unloaded MSIs decreased during the first 3 weeks and increased thereafter. Although the effects of pilot holes on stability could not be confirmed, placement of MSIs into nonkeratinized tissue negatively affected their stability and increased the likelihood of failures.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21612317      PMCID: PMC8903854          DOI: 10.2319/120810-711.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  39 in total

Review 1.  Ailing and failing endosseous dental implants: a literature review.

Authors:  Eric T Ashley; Lemuel L Covington; Barry G Bishop; Lawrence G Breault
Journal:  J Contemp Dent Pract       Date:  2003-05-15

2.  Resonance frequency analysis of implants subjected to immediate or early functional occlusal loading. Successful vs. failing implants.

Authors:  Roland Glauser; Lars Sennerby; Neil Meredith; Andreas Rée; AnnaKarin Lundgren; Jan Gottlow; Christoph H F Hämmerle
Journal:  Clin Oral Implants Res       Date:  2004-08       Impact factor: 5.977

3.  Biomechanical and histological comparison of self-drilling and self-tapping orthodontic microimplants in dogs.

Authors:  Yan Chen; Hong-In Shin; Hee-Moon Kyung
Journal:  Am J Orthod Dentofacial Orthop       Date:  2008-01       Impact factor: 2.650

Review 4.  Mini-implants in orthodontics: a systematic review of the literature.

Authors:  Reint Reynders; Laura Ronchi; Shandra Bipat
Journal:  Am J Orthod Dentofacial Orthop       Date:  2009-05       Impact factor: 2.650

5.  2008 survey of AAO members on miniscrew usage.

Authors:  Peter H Buschang; Roberto Carrillo; Brian Ozenbaugh; P Emile Rossouw
Journal:  J Clin Orthod       Date:  2008-09

6.  Survival analyses of surgical miniscrews as orthodontic anchorage.

Authors:  Nita Viwattanatipa; Sukalya Thanakitcharu; Akasith Uttraravichien; Waranuch Pitiphat
Journal:  Am J Orthod Dentofacial Orthop       Date:  2009-07       Impact factor: 2.650

Review 7.  Implant stability measurements using resonance frequency analysis: biological and biomechanical aspects and clinical implications.

Authors:  Lars Sennerby; Neil Meredith
Journal:  Periodontol 2000       Date:  2008       Impact factor: 7.589

Review 8.  Bone tissue interface.

Authors:  W E Roberts
Journal:  J Dent Educ       Date:  1988-12       Impact factor: 2.264

9.  Increased bone formation around coated implants.

Authors:  Bernd Stadlinger; Susanne Bierbaum; Silke Grimmer; Matthias C Schulz; Eberhard Kuhlisch; Dieter Scharnweber; Uwe Eckelt; Ronald Mai
Journal:  J Clin Periodontol       Date:  2009-06-15       Impact factor: 8.728

10.  Factors associated with initial stability of miniscrews for orthodontic treatment.

Authors:  Hoi-Jeong Lim; Chun-Sun Eun; Jin-Hyoung Cho; Ki-Heon Lee; Hyeon-Shik Hwang
Journal:  Am J Orthod Dentofacial Orthop       Date:  2009-08       Impact factor: 2.650

View more
  8 in total

1.  Laser-treated stainless steel mini-screw implants: 3D surface roughness, bone-implant contact, and fracture resistance analysis.

Authors:  He-Kyong Kang; Tien-Min Chu; Paul Dechow; Kelton Stewart; Hee-Moon Kyung; Sean Shih-Yao Liu
Journal:  Eur J Orthod       Date:  2015-04-23       Impact factor: 3.075

2.  Evaluation of miniscrew stability using an automatic embedding auxiliary skeletal anchorage device.

Authors:  Yasuhiko Oga; Hiroshi Tomonari; Sangho Kwon; Takaharu Kuninori; Takakazu Yagi; Shouichi Miyawaki
Journal:  Angle Orthod       Date:  2018-09-01       Impact factor: 2.079

3.  Photobiomodulation stimulates surrounding bone formation and increases stability of titanium alloy miniscrews in ovariectomized rats.

Authors:  Bruna Guimarães Martins; Vanessa Santos de Moura; Denise Nami Fujii; Aguinaldo Silva Garcez; Selly Sayuri Suzuki
Journal:  Lasers Med Sci       Date:  2022-04-14       Impact factor: 2.555

4.  Mini-implant stability at the initial healing period: a clinical pilot study.

Authors:  Manuel Nienkemper; Benedict Wilmes; Alexander Pauls; Dieter Drescher
Journal:  Angle Orthod       Date:  2013-07-24       Impact factor: 2.079

5.  Influence of late removal after treatment on the removal torque of microimplants.

Authors:  Ho-Jin Kim; Hyo-Sang Park
Journal:  Korean J Orthod       Date:  2022-05-25       Impact factor: 1.361

6.  Reader's Forum.

Authors:  Yongwen Guo
Journal:  Korean J Orthod       Date:  2014-05       Impact factor: 1.372

7.  Stability of immediately loaded 3 mm long miniscrew implants: a feasibility study.

Authors:  Danielle Geshay; Phillip Campbell; Larry Tadlock; Emet Schneiderman; Hee-Moon Kyung; Peter Buschang
Journal:  Dental Press J Orthod       Date:  2021-03-22

8.  Histomorphometric evaluation of the bone surrounding orthodontic miniscrews according to their adjacent root proximity.

Authors:  Hyun-Ju Oh; Jung-Yul Cha; Hyung-Seog Yu; Chung-Ju Hwang
Journal:  Korean J Orthod       Date:  2018-08-08       Impact factor: 1.372

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.