Literature DB >> 23883287

Mini-implant stability at the initial healing period: a clinical pilot study.

Manuel Nienkemper1, Benedict Wilmes, Alexander Pauls, Dieter Drescher.   

Abstract

OBJECTIVE: To evaluate the changes of mini-implant stability over the initial healing period in humans.
MATERIAL AND METHODS: A sample of 19 consecutively treated patients (mean age 15.5 ± 7.3 years) was examined. In each patient, a mini-implant of a size of 2 × 9 mm was inserted into the anterior palate. Implant stability was assessed using resonance frequency analysis (RFA) immediately after insertion (T0), 2 weeks later (T1), 4 weeks later (T2), and 6 weeks later (T3). Insertion depth (ID) and the maximum insertion torque (IT) were measured. Data were tested for correlations between RFA, ID, and IT. All RFA values were tested for statistically significant differences between the different times.
RESULTS: The mean ID was 7.5 ± 0.6 mm, and the mean IT was 16.8 ± 0.6 Ncm. A correlation was found between RFA and ID (r = .726, P < .0001), whereas no correlations between RFA and IT or between IT and ID were observed. From T0 to T1, the stability (36.1 ± 6.1 implant stability quotient [ISQ]) decreased nonsignificantly by 4.9 ± 6.1 ISQ values (P > .05). Between T1 and T2, the stability decreased highly significantly (P < .001) by 7.9 ± 5.9 ISQ values. From T2 on, RFA remained nearly unchanged (-1.7 ± 3.5 ISQ; P > .05).
CONCLUSIONS: Mini-implant stability is subject to changes during the healing process. During weeks 3 and 4, a significant decrease of the stability was observed. After 4 weeks, the stability did not change significantly.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23883287      PMCID: PMC8683051          DOI: 10.2319/040813-271.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  31 in total

1.  Bone response to unloaded titanium implants in the fibula, iliac crest, and scapula: an animal study in the Yorkshire pig.

Authors:  D Rohner; C S Meng; D W Hutmacher; K T Tsai
Journal:  Int J Oral Maxillofac Surg       Date:  2003-08       Impact factor: 2.789

2.  Factors influencing resonance frequency analysis assessed by Osstell mentor during implant tissue integration: I. Instrument positioning, bone structure, implant length.

Authors:  Christina P C Sim; Niklaus P Lang
Journal:  Clin Oral Implants Res       Date:  2010-06       Impact factor: 5.977

3.  Histological and fluorescence microscopic examination of the bone/implant interface in orthodontic miniscrews (Mondeal).

Authors:  T Gedrange; P Proff; T Bayerlein; P Landsberger; S Dietze; J Fanghänel
Journal:  Folia Morphol (Warsz)       Date:  2006-02       Impact factor: 1.183

4.  Soft-tissue and cortical-bone thickness at orthodontic implant sites.

Authors:  Hee-Jin Kim; Hee-Sun Yun; Hyun-Do Park; Doo-Hyung Kim; Young-Chel Park
Journal:  Am J Orthod Dentofacial Orthop       Date:  2006-08       Impact factor: 2.650

5.  Stability change of chemically modified sandblasted/acid-etched titanium palatal implants. A randomized-controlled clinical trial.

Authors:  Marc Schätzle; Roland Männchen; Ulrike Balbach; Christoph H F Hämmerle; Helge Toutenburg; Ronald E Jung
Journal:  Clin Oral Implants Res       Date:  2009-03-11       Impact factor: 5.977

Review 6.  Assessment of implant stability as a prognostic determinant.

Authors:  N Meredith
Journal:  Int J Prosthodont       Date:  1998 Sep-Oct       Impact factor: 1.681

7.  A comparison of implant stability quotients measured using magnetic resonance frequency analysis from two directions: a prospective clinical study during the initial healing period.

Authors:  Jong-Chul Park; Hyun-Duck Kim; Soung-Min Kim; Myung-Jin Kim; Jong-Ho Lee
Journal:  Clin Oral Implants Res       Date:  2010-02-01       Impact factor: 5.977

8.  Predictability of the resonance frequency analysis in the survival of dental implants placed in the anterior non-atrophied edentulous mandible.

Authors:  R González-García; F Monje; C Moreno-García
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2011-08-01

9.  Factors influencing resonance frequency analysis assessed by Osstell mentor during implant tissue integration: II. Implant surface modifications and implant diameter.

Authors:  Jie Han; Martina Lulic; Niklaus P Lang
Journal:  Clin Oral Implants Res       Date:  2010-06       Impact factor: 5.977

10.  Bone thickness of the palate for orthodontic mini-implant anchorage in adults.

Authors:  Sungmin Kang; Shin-Jae Lee; Sug-Joon Ahn; Min-Suk Heo; Tae-Woo Kim
Journal:  Am J Orthod Dentofacial Orthop       Date:  2007-04       Impact factor: 2.650

View more
  8 in total

1.  Insertion torque values and success rates for paramedian insertion of orthodontic mini-implants : A retrospective study.

Authors:  Bruno Di Leonardo; Björn Ludwig; Jörg Alexander Lisson; Luca Contardo; Rossano Mura; Jan Hourfar
Journal:  J Orofac Orthop       Date:  2018-02-20       Impact factor: 1.938

2.  An interview with Benedict Wilmes.

Authors:  Guilherme Thiesen; Marcus Vinícius Neiva Nunes do Rego; Jorge Faber; Ki Beom Kim
Journal:  Dental Press J Orthod       Date:  2016 Nov-Dec

3.  Impact of mini-implant length on stability at the initial healing period: a controlled clinical study.

Authors:  Manuel Nienkemper; Benedict Wilmes; Alexander Pauls; Dieter Drescher
Journal:  Head Face Med       Date:  2013-10-20       Impact factor: 2.151

4.  Risk of root damage after using lateral cephalogram and intraoral scan for guided insertion of palatal miniscrews.

Authors:  Manuel Nienkemper; Björn Ludwig
Journal:  Head Face Med       Date:  2022-09-03       Impact factor: 2.246

5.  Torque Loss After Miniscrew Placement: An In-Vitro Study Followed by a Clinical Trial.

Authors:  Marco Migliorati; Sara Drago; Fabrizio Barberis; Irene Schiavetti; Domenico Dalessandri; Stefano Benedicenti; Armando Silvestrini Biavati
Journal:  Open Dent J       Date:  2016-05-31

6.  Maxillary anterior en masse retraction using different antero-posterior position of mini screw: a 3D finite element study.

Authors:  Zohreh Hedayati; Mehrdad Shomali
Journal:  Prog Orthod       Date:  2016-10-03       Impact factor: 2.750

7.  RFA measurements of survival midpalatal orthodontic mini-implants in comparison to initial healing period.

Authors:  Manuel Nienkemper; Jan H Willmann; Kathrin Becker; Dieter Drescher
Journal:  Prog Orthod       Date:  2020-02-17       Impact factor: 2.750

8.  Bone remodelling patterns around orthodontic mini-implants migrating in bone: an experimental study in rat vertebrae.

Authors:  Kathrin Becker; Nicole Rauch; Giulia Brunello; Sarah Azimi; Mathias Beller; Mira Hüfner; Manuel Nienkemper; Beryl Schwarz-Herzke; Dieter Drescher
Journal:  Eur J Orthod       Date:  2021-12-01       Impact factor: 3.075

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.