Literature DB >> 3057027

Bone tissue interface.

W E Roberts1.   

Abstract

High resolution microradiography and multiple fluorochrome labeling are definitive histological methods for assessing the mechanism and timing of osseous healing, maturation, and adaptation. Two fundamental types of bone interface have been described for endosseous dental implants: (1) fibro-osseous integration ("pseudo-periodontal ligament") and (2) rigid osseous fixation ("osseointegration"). No definitive bone interface studies with modern physiological methods have been reported for fibro-osseous integration. Rigid osseous fixation has been investigated in cortical bone implantation sites. The initial healing reaction involves predominantly bone modeling at the periosteal and endosteal surfaces, i.e., a woven bone callus fills with lamellae by the process of lamellar compaction. Nonvital osseous interface and adjacent compacta are replaced by bone remodeling (turnover). As assessed with high resolution microradiography, "clinically successful" specimens had less than half of the intraosseous interface in direct contact with bone. Extrapolation from animal data suggests that endosseous implants can be provisionally loaded at about 18 weeks, but full maturation of the interface requires approximately one year.

Mesh:

Year:  1988        PMID: 3057027

Source DB:  PubMed          Journal:  J Dent Educ        ISSN: 0022-0337            Impact factor:   2.264


  18 in total

1.  Effects of orthodontic tooth movement on alveolar bone density.

Authors:  Hsing-Wen Chang; Heng-Li Huang; Jian-Hong Yu; Jui-Ting Hsu; Yu-Fen Li; Yi-Fan Wu
Journal:  Clin Oral Investig       Date:  2011-04-26       Impact factor: 3.573

Review 2.  Implants in bone: part II. Research on implant osseointegration: material testing, mechanical testing, imaging and histoanalytical methods.

Authors:  Cornelius von Wilmowsky; Tobias Moest; Emeka Nkenke; Florian Stelzle; Karl Andreas Schlegel
Journal:  Oral Maxillofac Surg       Date:  2013-02-21

3.  Stability changes of miniscrew implants over time.

Authors:  Derid S Ure; Donald R Oliver; Ki Beom Kim; Ana Cláudia Melo; Peter H Buschang
Journal:  Angle Orthod       Date:  2011-05-25       Impact factor: 2.079

4.  A comparison of the implant stability among various implant systems: clinical study.

Authors:  Jae-Min Kim; Sun-Jong Kim; Inho Han; Sang-Wan Shin; Jae-Jun Ryu
Journal:  J Adv Prosthodont       Date:  2009-03-31       Impact factor: 1.904

5.  Effect of decreased implant healing time on bone (re)modeling adjacent to plateaued implants under functional loading in a dog model.

Authors:  Jing Dai; Ning Cheng; Richard J Miron; Bin Shi; Xiangrong Cheng; Yufeng Zhang
Journal:  Clin Oral Investig       Date:  2013-02-03       Impact factor: 3.573

6.  A histomorphometric study on collagen-apatite composite as a graft material: the influence of gap size at the titanium-bone interface in animal model.

Authors:  Sung-Soo Shin; Jun Woo Park; Hyun-Man Kim; Jea Seung Ko; Pil-Young Yun
Journal:  J Mater Sci Mater Med       Date:  2009-04-04       Impact factor: 3.896

7.  Development of implant loading device for animal study about various loading protocol: a pilot study.

Authors:  Joon-Ho Yoon; Young-Bum Park; Yuna Cho; Chang-Sung Kim; Seong-Ho Choi; Hong-Seok Moon; Keun-Woo Lee; June-Sung Shim
Journal:  J Adv Prosthodont       Date:  2012-11-29       Impact factor: 1.904

8.  Evaluation of stability changes in tapered and parallel wall implants: a human clinical trial.

Authors:  Ar Rokn; Aar Rasouli Ghahroudi; A Mesgarzadeh; Aa Miremadi; S Yaghoobi
Journal:  J Dent (Tehran)       Date:  2011-12-20

Review 9.  Cell-based bone tissue engineering.

Authors:  Gert J Meijer; Joost D de Bruijn; Ron Koole; Clemens A van Blitterswijk
Journal:  PLoS Med       Date:  2007-02       Impact factor: 11.069

10.  Role of matrix metalloproteinase 13 in both endochondral and intramembranous ossification during skeletal regeneration.

Authors:  Danielle J Behonick; Zhiqing Xing; Shirley Lieu; Jenni M Buckley; Jeffrey C Lotz; Ralph S Marcucio; Zena Werb; Theodore Miclau; Céline Colnot
Journal:  PLoS One       Date:  2007-11-07       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.