Literature DB >> 21591013

Noncontrast MR angiography for comprehensive assessment of abdominopelvic arteries using quadruple inversion-recovery preconditioning and 3D balanced steady-state free precession imaging.

Iliyana P Atanasova1, Daniel Kim, Ruth P Lim, Pippa Storey, Sooah Kim, Hua Guo, Vivian S Lee.   

Abstract

PURPOSE: To develop a noncontrast magnetic resonance angiography (MRA) method for comprehensive evaluation of abdominopelvic arteries in a single 3D acquisition.
MATERIALS AND METHODS: A noncontrast MRA (NC MRA) pulse sequence was developed using four inversion-recovery (IR) pulses and 3D balanced steady-state free precession (b-SSFP) readout to provide arterial imaging from renal to external iliac arteries. Respiratory triggered, high spatial resolution (1.3 × 1.3 × 1.7 mm(3)) noncontrast angiograms were obtained in seven volunteers and ten patients referred for gadolinium-enhanced MRA (CE MRA). Images were assessed for diagnostic quality by two radiologists. Quantitative measurements of arterial signal contrast were also performed.
RESULTS: NC MRA imaging was successfully completed in all subjects in 7.0 ± 2.3 minutes. In controls, image quality of NC MRA averaged 2.79 ± 0.39 on a scale of 0-3, where 3 is maximum. Image quality of NC MRA (2.65 ± 0.41) was comparable to that of CE MRA (2.9 ± 0.32) in all patients. Contrast ratio measurements in patients demonstrated that NC MRA provides arterial contrast comparable to source CE MRA images with adequate venous and excellent background tissue suppression.
CONCLUSION: The proposed noncontrast MRA pulse sequence provides high-quality visualization of abdominopelvic arteries within clinically feasible scan times.
Copyright © 2011 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21591013      PMCID: PMC3097061          DOI: 10.1002/jmri.22564

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  20 in total

1.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

2.  Musculoskeletal MRI at 3.0 T: relaxation times and image contrast.

Authors:  Garry E Gold; Eric Han; Jeff Stainsby; Graham Wright; Jean Brittain; Christopher Beaulieu
Journal:  AJR Am J Roentgenol       Date:  2004-08       Impact factor: 3.959

3.  High-resolution MR-imaging of the liver with T2-weighted sequences using integrated parallel imaging: comparison of prospective motion correction and respiratory triggering.

Authors:  Christoph J Zech; Karin A Herrmann; Armin Huber; Olaf Dietrich; Alto Stemmer; Peter Herzog; Maximilian F Reiser; Stefan O Schoenberg
Journal:  J Magn Reson Imaging       Date:  2004-09       Impact factor: 4.813

4.  Free-breathing renal MR angiography with steady-state free-precession (SSFP) and slab-selective spin inversion: initial results.

Authors:  Marcus Katoh; Arno Buecker; Matthias Stuber; Rolf W Günther; Elmar Spuentrup
Journal:  Kidney Int       Date:  2004-09       Impact factor: 10.612

5.  MR imaging relaxation times of abdominal and pelvic tissues measured in vivo at 3.0 T: preliminary results.

Authors:  Cedric M J de Bazelaire; Guillaume D Duhamel; Neil M Rofsky; David C Alsop
Journal:  Radiology       Date:  2004-03       Impact factor: 11.105

6.  Multiple inversion recovery reduces static tissue signal in angiograms.

Authors:  W T Dixon; M Sardashti; M Castillo; G P Stomp
Journal:  Magn Reson Med       Date:  1991-04       Impact factor: 4.668

7.  Renal transplant: nonenhanced renal MR angiography with magnetization-prepared steady-state free precession.

Authors:  Xin Liu; Natasha Berg; John Sheehan; Xiaoming Bi; Peter Weale; Renate Jerecic; James Carr
Journal:  Radiology       Date:  2009-03-04       Impact factor: 11.105

8.  Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography: usefulness of a timing examination and MR power injector.

Authors:  J P Earls; N M Rofsky; D R DeCorato; G A Krinsky; J C Weinreb
Journal:  Radiology       Date:  1996-12       Impact factor: 11.105

9.  Gadolinium-enhanced MR aortography.

Authors:  M R Prince
Journal:  Radiology       Date:  1994-04       Impact factor: 11.105

10.  Improved arterial visibility using short-tau inversion-recovery (STIR) fat suppression in non-contrast-enhanced time-spatial labeling inversion pulse (Time-SLIP) renal MR angiography (MRA).

Authors:  Takaharu Shonai; Tadashi Takahashi; Hiroaki Ikeguchi; Mitsue Miyazaki; Kiyoka Amano; Masao Yui
Journal:  J Magn Reson Imaging       Date:  2009-06       Impact factor: 4.813

View more
  10 in total

1.  Non-contrast-enhanced abdominal MRA at 3 T using velocity-selective pulse trains.

Authors:  Dan Zhu; Wenbo Li; Dapeng Liu; Guanshu Liu; Yigang Pei; Taehoon Shin; Farzad Sedaghat; Qin Qin
Journal:  Magn Reson Med       Date:  2020-02-04       Impact factor: 4.668

Review 2.  Use of Multiplied, Added, Subtracted and/or FiTted Inversion Recovery (MASTIR) pulse sequences.

Authors:  Ya-Jun Ma; Shujuan Fan; Hongda Shao; Jiang Du; Nikolaus M Szeverenyi; Ian R Young; Graeme M Bydder
Journal:  Quant Imaging Med Surg       Date:  2020-06

3.  Velocity-selective magnetization-prepared non-contrast-enhanced cerebral MR angiography at 3 Tesla: Improved immunity to B0/B1 inhomogeneity.

Authors:  Qin Qin; Taehoon Shin; Michael Schär; Hua Guo; Hanwei Chen; Ye Qiao
Journal:  Magn Reson Med       Date:  2015-05-02       Impact factor: 4.668

4.  Non-contrast-enhanced renal and abdominal MR angiography using velocity-selective inversion preparation.

Authors:  Taehoon Shin; Pauline W Worters; Bob S Hu; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2012-06-18       Impact factor: 4.668

5.  Whole-brain arteriography and venography: Using improved velocity-selective saturation pulse trains.

Authors:  Wenbo Li; Feng Xu; Michael Schär; Jing Liu; Taehoon Shin; Yansong Zhao; Peter C M van Zijl; Bruce A Wasserman; Ye Qiao; Qin Qin
Journal:  Magn Reson Med       Date:  2017-08-10       Impact factor: 4.668

6.  Quadruple inversion-recovery b-SSFP MRA of the abdomen: initial clinical validation.

Authors:  Iliyana P Atanasova; Ruth P Lim; Hersh Chandarana; Pippa Storey; Mary T Bruno; Daniel Kim; Vivian S Lee
Journal:  Eur J Radiol       Date:  2014-06-02       Impact factor: 3.528

7.  Identification and reduction of image artifacts in non-contrast-enhanced velocity-selective peripheral angiography at 3T.

Authors:  Taehoon Shin; Qin Qin; Jang-Yeon Park; Robert S Crawford; Sanjay Rajagopalan
Journal:  Magn Reson Med       Date:  2015-08-26       Impact factor: 4.668

8.  Comparison of quiescent inflow single-shot and native space for nonenhanced peripheral MR angiography.

Authors:  Emily V Ward; Mauricio S Galizia; Asad Usman; Andrada R Popescu; Eugene Dunkle; Robert R Edelman
Journal:  J Magn Reson Imaging       Date:  2013-04-05       Impact factor: 4.813

9.  Noncontrast-enhanced renal angiography using multiple inversion recovery and alternating TR balanced steady-state free precession.

Authors:  Hattie Z Dong; Pauline W Worters; Holden H Wu; R Reeve Ingle; Shreyas S Vasanawala; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2012-11-21       Impact factor: 4.668

10.  Comparison of computed tomographic angiography and noncontrast magnetic resonance angiography in preoperative evaluation of living renal donors.

Authors:  Abhijit Dnyandeo Patil; K Shailage; Jeyaseelan Nadarajah; P Harigovind; R Krishna Mohan
Journal:  Indian J Urol       Date:  2017 Jan-Mar
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.