Literature DB >> 15332252

High-resolution MR-imaging of the liver with T2-weighted sequences using integrated parallel imaging: comparison of prospective motion correction and respiratory triggering.

Christoph J Zech1, Karin A Herrmann, Armin Huber, Olaf Dietrich, Alto Stemmer, Peter Herzog, Maximilian F Reiser, Stefan O Schoenberg.   

Abstract

PURPOSE: To compare high-resolution T2-weighted images of the liver with and without integrated parallel acquisition techniques (iPAT) using either breath-hold sequences in combination with prospective acquisition motion correction (PACE) or respiratory triggering.
MATERIALS AND METHODS: Ten volunteers and 10 patients underwent each four different high-resolution fast spin echo (FSE) T2-weighted sequences with 5 mm slice thickness and a full 320 matrix: a multi-breath-hold FSE sequence with and without iPAT and PACE and a respiratory-triggered FSE sequence with and without iPAT. Image quality was rated with a five-point scale by two independent readers. Signal intensity measurements were performed on a water phantom.
RESULTS: The sequences with iPAT required a substantially shorter acquisition time without loss of image quality. Overall image quality was rated equal for all sequences by both readers. Image time for nine slices with iPAT was 13 seconds (19 seconds without iPAT) with multi-breath-hold and on average 4:00 minutes (7:02 minutes without iPAT) with respiratory triggering. Imaging with the PACE technique resulted in more correct positioning of the image stacks.
CONCLUSION: T2-weighted fast imaging with iPAT is feasible and results in high-quality images within a short acquisition time. Overall image quality is not negatively affected by iPAT. Copyright 2004 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2004        PMID: 15332252     DOI: 10.1002/jmri.20127

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  21 in total

Review 1.  Imaging and image-guided radiation therapy in liver cancer.

Authors:  Kristy K Brock
Journal:  Semin Radiat Oncol       Date:  2011-10       Impact factor: 5.934

Review 2.  [Modern visualization of the liver with MRT. Current trends and future perspectives].

Authors:  C J Zech; S O Schoenberg; K A Herrmann; O Dietrich; M I Menzel; T Lanz; A Wallnöfer; T Helmberger; M F Reiser
Journal:  Radiologe       Date:  2004-12       Impact factor: 0.635

Review 3.  [Comparison of 2D and 3D sequences for MRCP. Clinical value of the different techniques].

Authors:  A M Wallnoefer; K A Herrmann; U Beuers; C J Zech; S Gourtsoyianni; M F Reiser; S O Schoenberg
Journal:  Radiologe       Date:  2005-11       Impact factor: 0.635

Review 4.  Parallel magnetic resonance imaging.

Authors:  Ulrich Katscher; Peter Börnert
Journal:  Neurotherapeutics       Date:  2007-07       Impact factor: 7.620

5.  Utility of navigator-prospective acquisition correction technique (PACE) for reducing motion in brain MR imaging studies.

Authors:  J D Barnwell; J K Smith; M Castillo
Journal:  AJNR Am J Neuroradiol       Date:  2007-04       Impact factor: 3.825

6.  Prospective comparison of high- and low-spatial-resolution dynamic MR imaging with sensitivity encoding (SENSE) for hypervascular hepatocellular carcinoma.

Authors:  Masakatsu Tsurusaki; Richard C Semelka; Kensuke Uotani; Koji Sugimoto; Masahiko Fujii; Kazuro Sugimura
Journal:  Eur Radiol       Date:  2008-04-30       Impact factor: 5.315

Review 7.  [New developments in MRI of the liver].

Authors:  N Bastati-Huber; H Prosch; S Baroud; S Magnaldi; W Schima; A Ba-Ssalamah
Journal:  Radiologe       Date:  2011-08       Impact factor: 0.635

8.  Hepatic fat assessment using advanced Magnetic Resonance Imaging.

Authors:  Yong Pang; Baiying Yu; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2012-09

9.  An MRI-compatible platform for one-dimensional motion management studies in MRI.

Authors:  Joris Nofiele; Qing Yuan; Mohammad Kazem; Ken Tatebe; Quinn Torres; Amit Sawant; Ivan Pedrosa; Rajiv Chopra
Journal:  Magn Reson Med       Date:  2015-10-23       Impact factor: 4.668

10.  Three-dimensional contrast-enhanced magnetic-resonance angiography of the renal arteries: interindividual comparison of 0.2 mmol/kg gadobutrol at 1.5 T and 0.1 mmol/kg gadobenate dimeglumine at 3.0 T.

Authors:  Ulrike I Attenberger; Henrik J Michaely; Bernd J Wintersperger; Steven P Sourbron; Klaus-Peter Lodemann; Maximilian F Reiser; Stefan O Schoenberg
Journal:  Eur Radiol       Date:  2008-02-16       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.