Literature DB >> 19261926

Renal transplant: nonenhanced renal MR angiography with magnetization-prepared steady-state free precession.

Xin Liu1, Natasha Berg, John Sheehan, Xiaoming Bi, Peter Weale, Renate Jerecic, James Carr.   

Abstract

The institutional review board approved this HIPAA-compliant study and waived informed consent. The purpose was to investigate nonenhanced magnetic resonance (MR) angiography with steady-state free precession (SSFP) with inversion recovery for assessing renal arteries in patients with renal transplants. Thirteen recipients of renal transplants underwent SSFP MR angiography before contrast material-enhanced MR angiography. Three stenoses (two mild, one severe) were identified at SSFP MR angiography in agreement with findings at contrast-enhanced MR angiography. There was no significant difference in image quality between the two methods. Results suggest SSFP MR angiography permits image quality of renal transplant arteries and detection of arterial stenosis comparable with those at contrast-enhanced MR angiography.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19261926     DOI: 10.1148/radiol.2512081094

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  17 in total

1.  Non-contrast-enhanced MRA of renal artery stenosis: validation against DSA in a porcine model.

Authors:  T A Bley; C J François; M L Schiebler; O Wieben; N Takei; J H Brittain; A Munoz Del Rio; T M Grist; S B Reeder
Journal:  Eur Radiol       Date:  2015-05-28       Impact factor: 5.315

Review 2.  Imaging of cardiovascular complications in patients with systemic lupus erythematosus.

Authors:  K Lin; D M Lloyd-Jones; D Li; Y Liu; J Yang; M Markl; J C Carr
Journal:  Lupus       Date:  2015-06-02       Impact factor: 2.911

3.  Dynamically applied B1+ shimming solutions for non-contrast enhanced renal angiography at 7.0 Tesla.

Authors:  Gregory J Metzger; Edward J Auerbach; Can Akgun; Josh Simonson; Xiaoming Bi; Kâmil Uğurbil; Pierre-François van de Moortele
Journal:  Magn Reson Med       Date:  2012-03-22       Impact factor: 4.668

Review 4.  Functional assessment of transplanted kidneys with magnetic resonance imaging.

Authors:  Yu-Ting Wang; Ying-Chun Li; Long-Lin Yin; Hong Pu; Jia-Yuan Chen
Journal:  World J Radiol       Date:  2015-10-28

5.  Noncontrast-enhanced magnetic resonance renal angiography using a repetitive artery and venous labelling technique at 3 T: comparison with contrast-enhanced magnetic resonance angiography in subjects with normal renal function.

Authors:  Sung Yoon Park; Chan Kyo Kim; EunJu Kim; Byung Kwan Park
Journal:  Eur Radiol       Date:  2014-09-13       Impact factor: 5.315

6.  Hemodynamic analysis of renal artery stenosis using computational fluid dynamics technology based on unenhanced steady-state free precession magnetic resonance angiography: preliminary results.

Authors:  Weisheng Zhang; Yi Qian; Jiang Lin; Peng Lv; Kaavya Karunanithi; Mengsu Zeng
Journal:  Int J Cardiovasc Imaging       Date:  2013-12-07       Impact factor: 2.357

7.  Assessment of the kidneys: magnetic resonance angiography, perfusion and diffusion.

Authors:  Ulrike I Attenberger; John N Morelli; Stefan O Schoenberg; Henrik J Michaely
Journal:  J Cardiovasc Magn Reson       Date:  2011-11-15       Impact factor: 5.364

8.  Non-contrast-enhanced magnetic resonance angiography: a reliable clinical tool for evaluating transplant renal artery stenosis.

Authors:  Long Jiang Zhang; Jin Peng; Jiqiu Wen; U Joseph Schoepf; Akos Varga-Szemes; L Parkwood Griffith; Yuan Meng Yu; Shu Min Tao; Yan Jun Li; Xue Feng Ni; Jian Xu; Dong Hong Shi; Guang Ming Lu
Journal:  Eur Radiol       Date:  2018-04-17       Impact factor: 5.315

9.  Quadruple inversion-recovery b-SSFP MRA of the abdomen: initial clinical validation.

Authors:  Iliyana P Atanasova; Ruth P Lim; Hersh Chandarana; Pippa Storey; Mary T Bruno; Daniel Kim; Vivian S Lee
Journal:  Eur J Radiol       Date:  2014-06-02       Impact factor: 3.528

10.  3D noncontrast MR angiography of the distal lower extremities using flow-sensitive dephasing (FSD)-prepared balanced SSFP.

Authors:  Zhaoyang Fan; John Sheehan; Xiaoming Bi; Xin Liu; James Carr; Debiao Li
Journal:  Magn Reson Med       Date:  2009-12       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.