Literature DB >> 21567469

Evaluation of BD Vacutainer SST™ II plus tubes for special proteins testing.

Zhiyan Li1, Cunling Yan, Rong Yan, Xinzhi Zheng, Zhenru Feng.   

Abstract

In the past few years, because of providing a closed system that allowed for collection, transport, processing, sampling, and storage of specimens, serum separator tubes gained widespread acceptance gradually in China. However, some limitations associated with gel tubes had been observed, for example, gel and analyte stability. In order to circumvent these problems, a new tube (BD Vacutainer(®) SST™ II Plus (BD SST™ II Plus)) containing a new gel was released by BD with respect to analyte and gel stability. We investigated the performance of BD SST™ II Plus tubes for special proteins testing using BD Vacutainer(®) Serum Glass Tubes (BD Serum Glass) as controls.Equivalence between these two types of tubes was demonstrated for all analytes at initial time, and data for all analytes except complement 3 (C3) and complement 4 (C4) indicated comparable stability over time in these two types of tubes. Concentration of C3 and C4 tended to increase with preservation time up to 72 hr in BD Serum Glass tubes. The stability of C3 and C4 was better in BD SST™ II Plus, which was demonstrated at timepoints up to 48 hr. We conclude that BD SST™ II Plus was suitable for collection and storage of samples for special proteins testing.
© 2011 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21567469      PMCID: PMC6647688          DOI: 10.1002/jcla.20458

Source DB:  PubMed          Journal:  J Clin Lab Anal        ISSN: 0887-8013            Impact factor:   2.352


  10 in total

1.  Effect of serum volume and time of exposure to gel barrier tubes on results for progesterone by Roche Diagnostics Elecsys 2010.

Authors:  J D Ferry; S Collins; E Sykes
Journal:  Clin Chem       Date:  1999-09       Impact factor: 8.327

2.  Time-dependent absorption of therapeutic drugs by the gel of the Greiner Vacuette blood collection tube.

Authors:  A Dasgupta; M A Yared; A Wells
Journal:  Ther Drug Monit       Date:  2000-08       Impact factor: 3.681

3.  Potential interferences from blood collection tubes in mass spectrometric analyses of serum polypeptides.

Authors:  Steven K Drake; Raffick A R Bowen; Alan T Remaley; Glen L Hortin
Journal:  Clin Chem       Date:  2004-12       Impact factor: 8.327

4.  Comparison of plastic vs. glass evacuated serum-separator (SST) blood-drawing tubes for common clinical chemistry determinations.

Authors:  B M Hill; R H Laessig; D D Koch; D J Hassemer
Journal:  Clin Chem       Date:  1992-08       Impact factor: 8.327

5.  Stability of twenty-five analytes in human serum at 22 degrees C, 4 degrees C, and -20 degrees C.

Authors:  J G Donnelly; S J Soldin; D A Nealon; J M Hicks
Journal:  Pediatr Pathol Lab Med       Date:  1995 Nov-Dec

6.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

7.  Absorption of therapeutic drugs by barrier gels in serum separator blood collection tubes. Volume- and time-dependent reduction in total and free drug concentrations.

Authors:  A Dasgupta; R Dean; S Saldana; G Kinnaman; R W McLawhon
Journal:  Am J Clin Pathol       Date:  1994-04       Impact factor: 2.493

8.  Influence of time, temperature and coagulation on the measurement of C3, C3 split products and C4.

Authors:  M J Sinosich; B Teisner; I Brandslund; M Fisher; J G Grudzinskas
Journal:  J Immunol Methods       Date:  1982-11-26       Impact factor: 2.303

9.  In vitro cold activation of complement shown by an overestimation of total complement 4: a study in patients with hepatitis C virus infection.

Authors:  O C Maguire; M P Curry; P O'Gorman; N Parfrey; J Hegarty; S K Cunningham
Journal:  Ann Clin Biochem       Date:  2001-11       Impact factor: 2.057

10.  Interference caused by the contents of serum separator tubes in the Vitros CRP assay.

Authors:  Chia-Yu Chang; Jin-Ying Lu; Tzu-I Chien; Jau-Tsuen Kao; Mei-Chun Lin; Pei-Chun Shih; Shiao-Ni Yan
Journal:  Ann Clin Biochem       Date:  2003-05       Impact factor: 2.057

  10 in total
  1 in total

1.  Serum Neuroinflammatory Disease-Induced Central Nervous System Proteins Predict Clinical Onset of Experimental Autoimmune Encephalomyelitis.

Authors:  Itay Raphael; Johanna Webb; Francisco Gomez-Rivera; Carol A Chase Huizar; Rishein Gupta; Bernard P Arulanandam; Yufeng Wang; William E Haskins; Thomas G Forsthuber
Journal:  Front Immunol       Date:  2017-07-17       Impact factor: 7.561

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.