Comparison of plastic vs. glass evacuated serum-separator (SST) blood-drawing tubes for common clinical chemistry determinations.

B M Hill1, R H Laessig, D D Koch, D J Hassemer.   

Abstract

We evaluated a plastic evacuated blood-drawing tube containing an integral serum-separating barrier gel, by direct comparison with a glass counterpart. The plastic tube demonstrated no differences when compared for common clinical chemistry analytes with multiple types of instruments and systems. A total of 260 such different combinations were studied with emphasis on tests sensitive to drawing and handling indexes such as lactate dehydrogenase and potassium. A total of six separate blood drawings were tested with no significant differences noted in these tests. The total study included subjective evaluations of the plastic tube's use as a blood-drawing device and objective studies based on quantitative test results from normal and hospitalized patients and use of the primary sampling tubes (both plastic and glass) for 48-h storage.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1643717

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  7 in total

1.  Evaluation of BD Vacutainer SST™ II Plus tubes for common tumor marker tests by Roche Diagnostics Modular E 170 analyzer.

Authors:  Zhiyan Li; Zhenru Feng; Cunling Yan; Rong Yan
Journal:  J Clin Lab Anal       Date:  2010       Impact factor: 2.352

2.  Evaluation of BD Vacutainer SST™ II plus tubes for special proteins testing.

Authors:  Zhiyan Li; Cunling Yan; Rong Yan; Xinzhi Zheng; Zhenru Feng
Journal:  J Clin Lab Anal       Date:  2011       Impact factor: 2.352

Review 3.  Methodological and statistical considerations for exercise-related hormone evaluations.

Authors:  M S Tremblay; S Y Chu; R Mureika
Journal:  Sports Med       Date:  1995-08       Impact factor: 11.136

4.  Different collection tubes in cardiac biomarkers detection.

Authors:  Massimo Daves; Diego Trevisan; Roberto Cemin
Journal:  J Clin Lab Anal       Date:  2008       Impact factor: 2.352

Review 5.  Sample preparation for serum/plasma profiling and biomarker identification by mass spectrometry.

Authors:  Jose L Luque-Garcia; Thomas A Neubert
Journal:  J Chromatogr A       Date:  2006-12-12       Impact factor: 4.759

6.  A comparative study on the effect of blood collection tubes on stress oxidative markers.

Authors:  Alireza Bastin; Saba Fooladi; Amir Hossein Doustimotlagh; Sina Vakili; Amir Hashem Aminizadeh; Sanaz Faramarz; Hamidreza Shiri; Mohammad Hadi Nematollahi
Journal:  PLoS One       Date:  2022-04-06       Impact factor: 3.240

7.  Comparison of digoxin concentration in plastic serum tubes with clot activator and heparinized plasma tubes.

Authors:  Lora Dukić; Ana-Maria Simundić; Davorin Malogorski
Journal:  Biochem Med (Zagreb)       Date:  2014-02-15       Impact factor: 2.313

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.