Literature DB >> 10942183

Time-dependent absorption of therapeutic drugs by the gel of the Greiner Vacuette blood collection tube.

A Dasgupta1, M A Yared, A Wells.   

Abstract

Stability of therapeutic drugs in sera collected in Becton-Dickinson VACUTAINER serum separator SST tubes has been well studied. Recently, the Greiner Vacuette serum separator tube has become available for blood collection. However, stability of therapeutic drugs in sera when the specimen is collected in the Greiner tube has not been reported. The authors studied the stability of 15 commonly monitored drugs in sera when stored on the gel of the Greiner serum separator tubes. The drugs studied were amikacin, gentamycin, tobramycin, vancomycin, digoxin, quinidine, theophylline, carbamazepine, phenobarbital, phenytoin, valproic acid, tricyclic antidepressants, salicylate, acetaminophen, and ethanol. The authors compared the concentrations of drugs in sera stored in plain tubes (no gel) and in sera stored in the Greiner tubes containing serum separator gel. They observed a significant decline in the concentrations of tricyclic antidepressants when stored in the Greiner tubes. Interestingly, concentrations of amitriptyline declined more than its metabolite nortriptyline and concentration of imipramine also decreased more than its metabolite desipramine. The concentration of carbamazepine also decreased slightly over time when serum was stored in the Greiner tube. Although declines in carbamazepine concentrations on prolonged storage in the Greiner tubes were statistically significant, the decreases may not be clinically significant. The concentrations of the other drugs studied did not decline when stored in the Greiner tubes. The authors conclude that the Greiner brand tube is not suitable for blood collection for analysis of tricyclic antidepressants.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10942183     DOI: 10.1097/00007691-200008000-00011

Source DB:  PubMed          Journal:  Ther Drug Monit        ISSN: 0163-4356            Impact factor:   3.681


  7 in total

1.  Evaluation of BD Vacutainer SST™ II Plus tubes for common tumor marker tests by Roche Diagnostics Modular E 170 analyzer.

Authors:  Zhiyan Li; Zhenru Feng; Cunling Yan; Rong Yan
Journal:  J Clin Lab Anal       Date:  2010       Impact factor: 2.352

2.  Evaluation of BD Vacutainer SST™ II plus tubes for special proteins testing.

Authors:  Zhiyan Li; Cunling Yan; Rong Yan; Xinzhi Zheng; Zhenru Feng
Journal:  J Clin Lab Anal       Date:  2011       Impact factor: 2.352

3.  Comparison of the effect of gel used in two different serum separator tubes for thyroid function tests.

Authors:  Müjgan Ercan; Esra Fırat Oğuz; Emiş Deniz Akbulut; Mustafa Yilmaz; Turan Turhan
Journal:  J Clin Lab Anal       Date:  2018-03-07       Impact factor: 2.352

4.  Recommendations for specimen collection for NBOMe analysis in clinical toxicology.

Authors:  Justin L Poklis; Carl E Wolf; Carrol R Nanco; Alphonse Poklis
Journal:  Clin Toxicol (Phila)       Date:  2015-12-22       Impact factor: 4.467

5.  Changes to serum sample tube and processing methodology does not cause Intra-Individual [corrected] variation in automated whole serum N-glycan profiling in health and disease.

Authors:  Nicholas T Ventham; Richard A Gardner; Nicholas A Kennedy; Archana Shubhakar; Rahul Kalla; Elaine R Nimmo; Daryl L Fernandes; Jack Satsangi; Daniel I R Spencer
Journal:  PLoS One       Date:  2015-04-01       Impact factor: 3.240

6.  Stability of 21 Antihypertensive Drugs in Serum Collected in Standard (Nongel) Serum Tubes Versus Tubes Containing a Gel Separator.

Authors:  Solfrid Hegstad; Olav Spigset; Arne Helland
Journal:  Ther Drug Monit       Date:  2020-04       Impact factor: 3.118

7.  Switching from serum to plasma: Implementation of BD Vacutainer® Barricor™ Plasma Blood Collection Tubes improves sample quality and laboratory turnaround time.

Authors:  Christian Ramakers; Brendan Meyer; Wanfei Yang; Elizabeth Plokhoy; Yan Xiong; Stephen Church; Nitin Kaushik
Journal:  Pract Lab Med       Date:  2019-12-10
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.