Literature DB >> 21559911

Effect of signal strength on reproducibility of circumpapillary retinal nerve fiber layer thickness measurement and its classification by spectral-domain optical coherence tomography.

Ji Hyun Kim1, Na Rae Kim1, Hyunjoong Kim2, Eun Suk Lee3, Gong Je Seong1, Chan Yun Kim1.   

Abstract

PURPOSE: To assess the effect of signal strength (SS) on the reproducibility of circumpapillary retinal nerve fiber layer (cpRNFL) thickness measurement (measurement agreement) and its color-coded classification (classification agreement) by Cirrus spectral-domain optical coherence tomography (OCT).
METHODS: Seven hundred and eighty-nine participants, consecutively enrolled from December 2009 to August 2010, underwent two repeated Cirrus OCT scans to measure cpRNFL thickness (optic disc cube 200 × 200). Intraclass correlation (ICC) and linear-weighted kappa coefficient (κ) were calculated as indicators for cpRNFL measurement and classification agreement. The difference in cpRNFL thickness measurements between repeated OCT scans (inter-scan measurement difference) was correlated with mean SS, SS change or difference between repeated OCT scans (inter-scan SS difference), and average cpRNFL thickness.
RESULTS: Mean SS was negatively correlated with inter-scan SS difference and was positively correlated with the inter-scan measurement difference. Repeated scans with SS change (inter-scan SS difference = 1 or 2) showed larger variability than scans without SS change (inter-scan SS difference = 0) in total average cpRNFL and all quadrant maps except for the nasal quadrant. Multivariate analysis revealed that inter-scan measurement differences increased in subjects with thinner cpRNFL thicknesses and in scans with lower mean SS and higher inter-scan SS differences. Measurement agreement (ICC) in groups with larger inter-scan SS differences (=2) was lower than those with smaller inter-scan SS differences (=0 or 1) in their average cpRNFL and inferior quadrant maps. Classification agreement (κ) in groups with larger inter-scan SS differences (=2) was lower than those with smaller inter-scan SS differences (=0 or 1) in their average cpRNFL and quadrant maps (superior and inferior quadrant) although statistically not significant.
CONCLUSIONS: Special attention should be paid when comparing the cpRNFL thickness measurement and color-coded classification of 2 or more Cirrus OCT scans as the agreements may be susceptible to SS differences.

Entities:  

Mesh:

Year:  2011        PMID: 21559911     DOI: 10.1007/s10384-011-0023-5

Source DB:  PubMed          Journal:  Jpn J Ophthalmol        ISSN: 0021-5155            Impact factor:   2.447


  16 in total

1.  Reproducibility of nerve fiber thickness, macular thickness, and optic nerve head measurements using StratusOCT.

Authors:  Lelia A Paunescu; Joel S Schuman; Lori Lyn Price; Paul C Stark; Siobahn Beaton; Hiroshi Ishikawa; Gadi Wollstein; James G Fujimoto
Journal:  Invest Ophthalmol Vis Sci       Date:  2004-06       Impact factor: 4.799

2.  Ophthalmic imaging by spectral optical coherence tomography.

Authors:  Maciej Wojtkowski; Tomasz Bajraszewski; Iwona Gorczyńska; Piotr Targowski; Andrzej Kowalczyk; Wojciech Wasilewski; Czesław Radzewicz
Journal:  Am J Ophthalmol       Date:  2004-09       Impact factor: 5.258

3.  Spectral domain optical coherence tomography: ultra-high speed, ultra-high resolution ophthalmic imaging.

Authors:  Teresa C Chen; Barry Cense; Mark C Pierce; Nader Nassif; B Hyle Park; Seok H Yun; Brian R White; Brett E Bouma; Guillermo J Tearney; Johannes F de Boer
Journal:  Arch Ophthalmol       Date:  2005-12

4.  Relationship between retinal nerve fiber layer measurement and signal strength in optical coherence tomography.

Authors:  Carol Yim Lui Cheung; Christopher Kai Shun Leung; Dusheung Lin; Chi-Pui Pang; Dennis Shun Chiu Lam
Journal:  Ophthalmology       Date:  2008-02-21       Impact factor: 12.079

5.  Reproducibility of peripapillary retinal nerve fiber layer thickness with spectral domain cirrus high-definition optical coherence tomography in normal eyes.

Authors:  Samin Hong; Chan Yun Kim; Won Seok Lee; Gong Je Seong
Journal:  Jpn J Ophthalmol       Date:  2010-02-12       Impact factor: 2.447

6.  Reproducibility of retinal nerve fiber thickness measurements using the stratus OCT in normal and glaucomatous eyes.

Authors:  Donald L Budenz; Robert T Chang; Xiangrun Huang; Robert W Knighton; James M Tielsch
Journal:  Invest Ophthalmol Vis Sci       Date:  2005-07       Impact factor: 4.799

7.  Comparison of retinal nerve fiber layer measurements using time domain and spectral domain optical coherent tomography.

Authors:  O'Rese J Knight; Robert T Chang; William J Feuer; Donald L Budenz
Journal:  Ophthalmology       Date:  2009-04-22       Impact factor: 12.079

8.  Reproducibility of peripapillary retinal nerve fiber thickness measurements with stratus OCT in glaucomatous eyes.

Authors:  Donald L Budenz; Marie-Josée Fredette; William J Feuer; Douglas R Anderson
Journal:  Ophthalmology       Date:  2007-08-13       Impact factor: 12.079

9.  Factors associated with variability in retinal nerve fiber layer thickness measurements obtained by optical coherence tomography.

Authors:  Ziqiang Wu; Matti Vazeen; Rohit Varma; Vikas Chopra; Alexander C Walsh; Laurie D LaBree; Srinivas R Sadda
Journal:  Ophthalmology       Date:  2007-03-23       Impact factor: 12.079

10.  Agreement between spectral-domain and time-domain OCT for measuring RNFL thickness.

Authors:  G Vizzeri; R N Weinreb; A O Gonzalez-Garcia; C Bowd; F A Medeiros; P A Sample; L M Zangwill
Journal:  Br J Ophthalmol       Date:  2009-03-19       Impact factor: 4.638

View more
  9 in total

1.  A comparison of false positives in retinal nerve fiber layer, optic nerve head and macular ganglion cell-inner plexiform layer from two spectral-domain optical coherence tomography devices.

Authors:  Marina Leal-Fonseca; Gema Rebolleda; Noelia Oblanca; Javier Moreno-Montañes; Francisco J Muñoz-Negrete
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-12-12       Impact factor: 3.117

2.  Intraobserver and interobserver agreement of computer software-assisted optic nerve head photoplanimetry.

Authors:  Masaki Tanito; Takeshi Sagara; Michiya Takamatsu; Yoshiaki Kiuchi; Toshiaki Nakagawa; Yasuyuki Fujita; Akihiro Ohira
Journal:  Jpn J Ophthalmol       Date:  2013-10-08       Impact factor: 2.447

Review 3.  Test-retest variability in structural parameters measured with glaucoma imaging devices.

Authors:  Makoto Araie
Journal:  Jpn J Ophthalmol       Date:  2012-11-09       Impact factor: 2.447

4.  Optimizing the information yield of 3-D OCT in glaucoma.

Authors:  Henriët Springelkamp; Kyungmoo Lee; Wishal D Ramdas; Johannes R Vingerling; Albert Hofman; Caroline C W Klaver; Milan Sonka; Michael D Abràmoff; Nomdo M Jansonius
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-12-13       Impact factor: 4.799

5.  Retinal Nerve Fibre Layer Thickness Increases with Decreasing Spectralis OCT Signal Strength in Normal Eyes.

Authors:  Margaret R Strampe; Luai Eldweik; Benjamin C Chaon; Sarah Maki; Tyler Wieland; Celine Satija; Collin McClelland; Michael S Lee
Journal:  Neuroophthalmology       Date:  2019-10-29

6.  Predictive value of preoperative optical coherence tomography for visual outcome following macular hole surgery: effects of imaging alignment.

Authors:  Wataru Matsumiya; Sentaro Kusuhara; Tsuyoshi Shimoyama; Shigeru Honda; Yasutomo Tsukahara; Akira Negi
Journal:  Jpn J Ophthalmol       Date:  2013-02-27       Impact factor: 2.447

7.  Longitudinal analysis of retinal nerve fiber layer and ganglion cell-inner plexiform layer thickness in ethambutol-induced optic neuropathy.

Authors:  Jinu Han; Min Kwang Byun; Junwon Lee; So Young Han; Jong Bok Lee; Sueng-Han Han
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-09-07       Impact factor: 3.117

8.  Optic disc rim area to retinal nerve fiber layer thickness correlation: comparison of diabetic and normal tension glaucoma eyes.

Authors:  Min Hee Suh; Seok Hwan Kim; Ki Ho Park; Hyeong Gon Yu; Jang Won Huh; Dong Myung Kim
Journal:  Jpn J Ophthalmol       Date:  2012-11-28       Impact factor: 2.447

9.  Thickness measurements taken with the spectralis OCT increase with decreasing signal strength.

Authors:  Assaf Gershoni; Edward Barayev; Igor Vainer; Raviv Allon; Roy Yavnieli; Yinon Shapira; Michael Mimouni; Noa Geffen; Arie Yehuda Nemet; Ori Segal
Journal:  BMC Ophthalmol       Date:  2022-04-01       Impact factor: 2.209

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.