Literature DB >> 17706287

Reproducibility of peripapillary retinal nerve fiber thickness measurements with stratus OCT in glaucomatous eyes.

Donald L Budenz1, Marie-Josée Fredette, William J Feuer, Douglas R Anderson.   

Abstract

PURPOSE: To determine the reproducibility of Stratus OCT peripapillary retinal nerve fiber layer (RNFL) measurements in glaucomatous eyes.
DESIGN: Experimental study. PARTICIPANTS: Fifty-one stable glaucoma patients with a range of severity.
METHODS: Peripapillary RNFL thickness was measured using the Standard and Fast scan protocols of Stratus optical coherence tomography (OCT) 3 times on the same day to determine intrasession variability and on 5 different days within a 2-month period to determine intersession variability. The same instrument was used by the same operator for all scans. MAIN OUTCOME MEASURES: Intraclass correlation coefficient (ICC), coefficient of variation (COV), and test-retest variability.
RESULTS: For mean RNFL thickness, the intrasession and intersession ICCs for the Standard and Fast scans were 0.98 and 0.96, respectively. The COV ranged from 3.8% to 5.2%. Test-retest variability was approximately 7 microm between sessions, most of which can be attributed to the approximate 5-microm variability within each session. For quadrants, the ICC was 0.9 or higher and the COV was under 10% except nasally. Test-retest variability for quadrant measurements ranged from 6 to 16 microm. For clock hours, test-retest variability approached 20 microm between sessions in some sectors. In general, the ICC was lower in the nasal region than elsewhere. Variability was greater the smaller the area over which RNFL thickness was determined. Intrasession variability was not a predictor of intersession variability in individual subjects (P Standard = 0.72, P Fast = 0.28). There was no relationship between variability and mean RNFL thickness (P Standard = 0.28, P Fast = 0.93).
CONCLUSIONS: The reproducibility of Stratus OCT for RNFL thickness is sufficiently good to be useful clinically as a measure of glaucoma progression. When comparing 2 mean RNFL values on different days in the same eye, an 8-microm decrease in thickness might be accepted as within normal limits of test-retest variability with 95% tolerance. For quadrants and clock-hour sectors, variability is higher, and more detailed calculations are necessary.

Entities:  

Mesh:

Year:  2007        PMID: 17706287     DOI: 10.1016/j.ophtha.2007.05.035

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  98 in total

1.  Glaucoma research community and FDA look to the future, II: NEI/FDA Glaucoma Clinical Trial Design and Endpoints Symposium: measures of structural change and visual function.

Authors:  Robert N Weinreb; Paul L Kaufman
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-10-04       Impact factor: 4.799

2.  Quantitative evaluation of papilledema from stereoscopic color fundus photographs.

Authors:  Li Tang; Randy H Kardon; Jui-Kai Wang; Mona K Garvin; Kyungmoo Lee; Michael D Abràmoff
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-07-03       Impact factor: 4.799

3.  Effect of signal strength on reproducibility of peripapillary retinal nerve fiber layer thickness measurement and its classification by time-domain optical coherence tomography.

Authors:  Eun Suk Lee; Hyunjoong Kim; Joon Mo Kim
Journal:  Jpn J Ophthalmol       Date:  2010-11-05       Impact factor: 2.447

4.  Progression of geographic atrophy in age-related macular degeneration imaged with spectral domain optical coherence tomography.

Authors:  Zohar Yehoshua; Philip J Rosenfeld; Giovanni Gregori; William J Feuer; Manuel Falcão; Brandon J Lujan; Carmen Puliafito
Journal:  Ophthalmology       Date:  2010-10-29       Impact factor: 12.079

5.  Head-down Posture in Glaucoma Suspects Induces Changes in IOP, Systemic Pressure, and PERG That Predict Future Loss of Optic Nerve Tissue.

Authors:  Vittorio Porciatti; William J Feuer; Pedro Monsalve; Giacinto Triolo; Luis Vazquez; John McSoley; Lori M Ventura
Journal:  J Glaucoma       Date:  2017-05       Impact factor: 2.503

6.  Symmetry between the right and left eyes of the normal retinal nerve fiber layer measured with optical coherence tomography (an AOS thesis).

Authors:  Donald L Budenz
Journal:  Trans Am Ophthalmol Soc       Date:  2008

7.  Retinal nerve fiber layer atrophy is associated with visual field loss over time in glaucoma suspect and glaucomatous eyes.

Authors:  Mitra Sehi; Xinbo Zhang; David S Greenfield; Yunsuk Chung; Gadi Wollstein; Brian A Francis; Joel S Schuman; Rohit Varma; David Huang
Journal:  Am J Ophthalmol       Date:  2012-10-01       Impact factor: 5.258

8.  Improved reproducibility of retinal nerve fiber layer thickness measurements with the repeat-scan protocol using the Stratus OCT in normal and glaucomatous eyes.

Authors:  Argyrios Tzamalis; Myron Kynigopoulos; Torsten Schlote; Ivan Haefliger
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2008-09-23       Impact factor: 3.117

Review 9.  High-resolution ocular imaging: combining advanced optics and microtechnology.

Authors:  M Francesca Cordeiro; Robert Nickells; Wolfgang Drexler; Terete Borrás; Robert Ritch
Journal:  Ophthalmic Surg Lasers Imaging       Date:  2009 Sep-Oct

10.  A test of a linear model of glaucomatous structure-function loss reveals sources of variability in retinal nerve fiber and visual field measurements.

Authors:  Donald C Hood; Susan C Anderson; Michael Wall; Ali S Raza; Randy H Kardon
Journal:  Invest Ophthalmol Vis Sci       Date:  2009-05-14       Impact factor: 4.799

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.