Literature DB >> 15161831

Reproducibility of nerve fiber thickness, macular thickness, and optic nerve head measurements using StratusOCT.

Lelia A Paunescu1, Joel S Schuman, Lori Lyn Price, Paul C Stark, Siobahn Beaton, Hiroshi Ishikawa, Gadi Wollstein, James G Fujimoto.   

Abstract

PURPOSE: The measurement reproducibility of the third generation of commercial optical coherence tomography, OCT-3 (StratusOCT, software ver. A2, Carl Zeiss Meditec Inc., Dublin, CA) was investigated. The nerve fiber layer (NFL) thickness, macula thickness map, and optic nerve head (ONH) parameters in normal eyes were studied.
METHODS: Ten normal subjects were imaged six times (three before and three after dilation) per day, and the series was repeated on three different days. The order of the scans before pupil dilation was randomized in each of the 3 days of scanning. After pupil dilation, the scans were also randomized in each of the 3 days of scanning. Each series was performed separately for standard-density (128 A-scans per macular and ONH image and 256 A-scans per NFL image) and high-density (512 A-scans per image for all three scan types) scanning.
RESULTS: The mean macular thickness was 235 +/- 9.8 micro m. A-scan density (or image acquisition speed) had a statistically significant effect (P < 0.05) on the reproducibility of the mean macular thickness, macular volume, and a few sectors of the macular map. No significant dilation effect was found for any of the macular parameters. The best intraclass correlation coefficient (ICC; 94%) for macular scans was found for dilated high-density scanning, with an intervisit SD of 2.4 micro m and an intravisit SD of 2.2 micro m. The mean NFL thickness for standard scanning was 98 +/- 9 micro m. NFL reproducibility showed mixed results and had interactions between scan density and dilation for some parameters. For most of the NFL parameters, reproducibility was better with dilated standard-density scanning. The mean NFL thickness ICC for dilated standard scanning was 79%, with an intervisit SD of 2.5 micro m and an intravisit SD of 1.6 micro m. For the ONH analysis, the reproducibility was better for dilated standard-density scanning for almost all the parameters, except for disc area, horizontal integrated rim volume, and vertical integrated rim area, which were better before dilation. The best reproducibility was found for cup-to-disc ratio (ICC = 97%, with intervisit SD of 0.04 micro m and intravisit SD of 0.02 micro m).
CONCLUSIONS: StratusOCT demonstrated reproducible measurements of NFL thickness, macular thickness, and optic nerve head parameters. The best reproducibility was found for dilated standard scanning for NFL and ONH parameters and for dilated high-density scanning for macular parameters.

Entities:  

Mesh:

Year:  2004        PMID: 15161831      PMCID: PMC1993821          DOI: 10.1167/iovs.03-0514

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  21 in total

1.  Retinal nerve fiber layer thickness in human eyes.

Authors:  A Dichtl; J B Jonas; G O Naumann
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1999-06       Impact factor: 3.117

2.  Reproducibility of nerve fiber layer thickness measurements by use of optical coherence tomography.

Authors:  E Z Blumenthal; J M Williams; R N Weinreb; C A Girkin; C C Berry; L M Zangwill
Journal:  Ophthalmology       Date:  2000-12       Impact factor: 12.079

3.  Optical coherence tomography.

Authors:  D Huang; E A Swanson; C P Lin; J S Schuman; W G Stinson; W Chang; M R Hee; T Flotte; K Gregory; C A Puliafito
Journal:  Science       Date:  1991-11-22       Impact factor: 47.728

Review 4.  Optical coherence tomography: a new tool for glaucoma diagnosis.

Authors:  J S Schuman; M R Hee; A V Arya; T Pedut-Kloizman; C A Puliafito; J G Fujimoto; E A Swanson
Journal:  Curr Opin Ophthalmol       Date:  1995-04       Impact factor: 3.761

5.  Quantification of nerve fiber layer thickness in normal and glaucomatous eyes using optical coherence tomography.

Authors:  J S Schuman; M R Hee; C A Puliafito; C Wong; T Pedut-Kloizman; C P Lin; E Hertzmark; J A Izatt; E A Swanson; J G Fujimoto
Journal:  Arch Ophthalmol       Date:  1995-05

6.  Optical coherence tomography of macular holes.

Authors:  M R Hee; C A Puliafito; C Wong; J S Duker; E Reichel; J S Schuman; E A Swanson; J G Fujimoto
Journal:  Ophthalmology       Date:  1995-05       Impact factor: 12.079

7.  Imaging of macular diseases with optical coherence tomography.

Authors:  C A Puliafito; M R Hee; C P Lin; E Reichel; J S Schuman; J S Duker; J A Izatt; E A Swanson; J G Fujimoto
Journal:  Ophthalmology       Date:  1995-02       Impact factor: 12.079

8.  Photocoagulation for diabetic macular edema. Early Treatment Diabetic Retinopathy Study report number 1. Early Treatment Diabetic Retinopathy Study research group.

Authors: 
Journal:  Arch Ophthalmol       Date:  1985-12

9.  Optical coherence tomography of central serous chorioretinopathy.

Authors:  M R Hee; C A Puliafito; C Wong; E Reichel; J S Duker; J S Schuman; E A Swanson; J G Fujimoto
Journal:  Am J Ophthalmol       Date:  1995-07       Impact factor: 5.258

10.  Comparison of optic nerve head measurements obtained by optical coherence tomography and confocal scanning laser ophthalmoscopy.

Authors:  Joel S Schuman; Gadi Wollstein; Taline Farra; Ellen Hertzmark; Ali Aydin; James G Fujimoto; Lelia A Paunescu
Journal:  Am J Ophthalmol       Date:  2003-04       Impact factor: 5.258

View more
  146 in total

1.  Quantitative analysis of the intraretinal layers and optic nerve head using ultra-high resolution optical coherence tomography.

Authors:  Yuhong Wang; Hong Jiang; Meixiao Shen; Byron L Lam; Delia Cabrera DeBuc; Yufeng Ye; Ming Li; Aizhu Tao; Yilei Shao; Jianhua Wang
Journal:  J Biomed Opt       Date:  2012-06       Impact factor: 3.170

2.  Comparison of central macular thickness between two spectral-domain optical coherence tomography in elderly non-mydriatic eyes.

Authors:  Xiao-Gang Wang; Qing Peng; Qiang Wu
Journal:  Int J Ophthalmol       Date:  2012-06-18       Impact factor: 1.779

3.  Better performance of RTVue than Cirrus spectral-domain optical coherence tomography in detecting band atrophy of the optic nerve.

Authors:  Makoto Nakamura; Kumiko Ishikawa-Tabuchi; Akiyasu Kanamori; Yuko Yamada; Akira Negi
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-07-01       Impact factor: 3.117

4.  Reproducibility and agreement in evaluating retinal nerve fibre layer thickness between Stratus and Spectralis OCT.

Authors:  S N Arthur; S D Smith; M M Wright; A L Grajewski; Q Wang; J M Terry; M S Lee
Journal:  Eye (Lond)       Date:  2010-11-26       Impact factor: 3.775

5.  Interpreting thickness changes in the diabetic macula: the problem of short-term variation in optical coherence tomography-measured macular thickening (an american ophthalmological society thesis).

Authors:  David J Browning
Journal:  Trans Am Ophthalmol Soc       Date:  2010-12

6.  Comparison and interchangeability of macular thickness measured with Cirrus OCT and Stratus OCT in myopic eyes.

Authors:  Geng Wang; Kun-Liang Qiu; Xue-Hui Lu; Ming-Zhi Zhang
Journal:  Int J Ophthalmol       Date:  2015-12-18       Impact factor: 1.779

7.  Retinal nerve fiber structure versus visual field function in patients with ischemic optic neuropathy. A test of a linear model.

Authors:  Donald C Hood; Susan Anderson; Jacinthe Rouleau; Adam S Wenick; Larissa K Grover; Myles M Behrens; Jeffrey G Odel; Andrew G Lee; Randy H Kardon
Journal:  Ophthalmology       Date:  2007-09-17       Impact factor: 12.079

8.  [Structural and morphological changes in the eyes of arterial hypertensive patients with and without anti-CCP-positive rheumatoid arthritis].

Authors:  M Pahlitzsch; R Zielke; S Schlittgen; K Göbel; R Alten; C Erb
Journal:  Ophthalmologe       Date:  2017-04       Impact factor: 1.059

9.  Scan tracking coordinates for improved centering of Stratus OCT scan pattern.

Authors:  Gianmarco Vizzeri; Christopher Bowd; Felipe A Medeiros; Robert N Weinreb; Linda M Zangwill
Journal:  J Glaucoma       Date:  2009-01       Impact factor: 2.503

10.  Improved reproducibility of retinal nerve fiber layer thickness measurements with the repeat-scan protocol using the Stratus OCT in normal and glaucomatous eyes.

Authors:  Argyrios Tzamalis; Myron Kynigopoulos; Torsten Schlote; Ivan Haefliger
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2008-09-23       Impact factor: 3.117

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.