PURPOSE: To demonstrate two novel ophthalmic imaging techniques based on fast Spectral Optical Coherence Tomography (SOCT). DESIGN: Prospective observation case report. SETTING: Research laboratory. STUDY POPULATION: A normal human subject. MAIN OUTCOME MEASURES: Correlation of an optical coherence retinal tomogram with known retinal anatomy, reduction of eye exposure to the probing light beam during Optical Coherence Tomography (OCT) examination. RESULTS: High resolution (3- x 20-microm) cross-sectional 2-dimensional images of the human retina in vivo have been obtained with only 0.1-second total illumination time (for 1024 A-scans), and approximately 200- microW eye exposure. Details of the optic disk in vivo have been visualized at a rate of eight frames per second, which is sufficient to provide real time analysis. The 3-dimensional images of the optic nerve correspond to the images obtained from a fundus camera. CONCLUSIONS: Because of its short acquisition time and high sensitivity, SOCT uses a 100 times lower exposure/A-scan to obtain images of comparable quality to those obtained by the commercial instrument based on traditional time-domain OCT. Spectral Optical Coherence Tomography therefore provides a much wider safety margin than the traditional method and allows relaxation of the current safety precautions forbidding more than 10 minutes/day scanning of the same location of a retina. As a result of the high speed offered by the new technique, the 3-dimensional tomograms, which allow a surgeon access to a comprehensive and detailed view of relevant pathologies, are obtained in a much shorter, clinically more reasonable time.
PURPOSE: To demonstrate two novel ophthalmic imaging techniques based on fast Spectral Optical Coherence Tomography (SOCT). DESIGN: Prospective observation case report. SETTING: Research laboratory. STUDY POPULATION: A normal human subject. MAIN OUTCOME MEASURES: Correlation of an optical coherence retinal tomogram with known retinal anatomy, reduction of eye exposure to the probing light beam during Optical Coherence Tomography (OCT) examination. RESULTS: High resolution (3- x 20-microm) cross-sectional 2-dimensional images of the human retina in vivo have been obtained with only 0.1-second total illumination time (for 1024 A-scans), and approximately 200- microW eye exposure. Details of the optic disk in vivo have been visualized at a rate of eight frames per second, which is sufficient to provide real time analysis. The 3-dimensional images of the optic nerve correspond to the images obtained from a fundus camera. CONCLUSIONS: Because of its short acquisition time and high sensitivity, SOCT uses a 100 times lower exposure/A-scan to obtain images of comparable quality to those obtained by the commercial instrument based on traditional time-domain OCT. Spectral Optical Coherence Tomography therefore provides a much wider safety margin than the traditional method and allows relaxation of the current safety precautions forbidding more than 10 minutes/day scanning of the same location of a retina. As a result of the high speed offered by the new technique, the 3-dimensional tomograms, which allow a surgeon access to a comprehensive and detailed view of relevant pathologies, are obtained in a much shorter, clinically more reasonable time.
Authors: Kyung Rim Sung; Jong S Kim; Gadi Wollstein; Lindsey Folio; Michael S Kook; Joel S Schuman Journal: Br J Ophthalmol Date: 2010-10-28 Impact factor: 4.638
Authors: Maciej Wojtkowski; Vivek Srinivasan; James G Fujimoto; Tony Ko; Joel S Schuman; Andrzej Kowalczyk; Jay S Duker Journal: Ophthalmology Date: 2005-10 Impact factor: 12.079
Authors: Annie Chan; Jay S Duker; Hiroshi Ishikawa; Tony H Ko; Joel S Schuman; James G Fujimoto Journal: Retina Date: 2006 Jul-Aug Impact factor: 4.256
Authors: Tony H Ko; Andre J Witkin; James G Fujimoto; Annie Chan; Adam H Rogers; Caroline R Baumal; Joel S Schuman; Wolfgang Drexler; Elias Reichel; Jay S Duker Journal: Arch Ophthalmol Date: 2006-06
Authors: Lisa S Schocket; Andre J Witkin; James G Fujimoto; Tony H Ko; Joel S Schuman; Adam H Rogers; Caroline Baumal; Elias Reichel; Jay S Duker Journal: Ophthalmology Date: 2006-04 Impact factor: 12.079
Authors: Vivek J Srinivasan; Maciej Wojtkowski; Andre J Witkin; Jay S Duker; Tony H Ko; Mariana Carvalho; Joel S Schuman; Andrzej Kowalczyk; James G Fujimoto Journal: Ophthalmology Date: 2006-11 Impact factor: 12.079
Authors: I Gorczynska; V J Srinivasan; L N Vuong; R W S Chen; J J Liu; E Reichel; M Wojtkowski; J S Schuman; J S Duker; J G Fujimoto Journal: Br J Ophthalmol Date: 2008-07-28 Impact factor: 4.638