Literature DB >> 18727086

Strongly modulating pulses for counteracting RF inhomogeneity at high fields.

N Boulant1, D Le Bihan, A Amadon.   

Abstract

A new pulse technique for counteracting RF inhomogeneity at high fields is reported. The pulses make use of the detailed knowledge of the voxels' B(1) and B(0) amplitude 2D histogram to generate, through an optimization procedure, gates where the flip angle is made uniform. Although most approaches to date require the use of parallel transmission, this method does not and therefore offers several advantages. The data necessary for the algorithm to determine an irradiation scheme requires only one transmit B(1) along with a B(0) inhomogeneity measurement. The use of a B(1) and B(0) amplitude 2D histogram instead of their spatial distribution also decreases substantially the complexity of the optimization problem, allowing the algorithm to find an RF solution in less than 30 s. Finally, the optimization procedure is based on an exact calculation and does not use any linear approximation. In this article, the theory behind the method in addition to spoiled gradient echo experimental data at 3T for 3D brain imaging are reported. The images obtained yield a reduction of the standard deviation of the sine of the flip angle by a factor of up to 15 around the desired value, compared to when a standard square pulse calibrated by the scanner is used.

Mesh:

Year:  2008        PMID: 18727086     DOI: 10.1002/mrm.21700

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  5 in total

1.  Composite RF pulses for B1+-insensitive volume excitation at 7 Tesla.

Authors:  Jay Moore; Marcin Jankiewicz; Huairen Zeng; Adam W Anderson; John C Gore
Journal:  J Magn Reson       Date:  2010-04-10       Impact factor: 2.229

2.  Whole-brain arteriography and venography: Using improved velocity-selective saturation pulse trains.

Authors:  Wenbo Li; Feng Xu; Michael Schär; Jing Liu; Taehoon Shin; Yansong Zhao; Peter C M van Zijl; Bruce A Wasserman; Ye Qiao; Qin Qin
Journal:  Magn Reson Med       Date:  2017-08-10       Impact factor: 4.668

3.  Slice-selective excitation with B₁⁺-insensitive composite pulses.

Authors:  Jay Moore; Marcin Jankiewicz; Adam W Anderson; John C Gore
Journal:  J Magn Reson       Date:  2011-11-18       Impact factor: 2.229

4.  Radiofrequency pulse designs for three-dimensional MRI providing uniform tipping in inhomogeneous B₁ fields.

Authors:  Hui Liu; Gerald B Matson
Journal:  Magn Reson Med       Date:  2011-04-26       Impact factor: 4.668

5.  Homogeneous non-selective and slice-selective parallel-transmit excitations at 7 Tesla with universal pulses: A validation study on two commercial RF coils.

Authors:  Vincent Gras; Markus Boland; Alexandre Vignaud; Guillaume Ferrand; Alexis Amadon; Franck Mauconduit; Denis Le Bihan; Tony Stöcker; Nicolas Boulant
Journal:  PLoS One       Date:  2017-08-21       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.